文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

机械通气患者膈肌组织学萎缩与超声呼气末膈肌厚度的关联

Association between histological diaphragm atrophy and ultrasound diaphragm expiratory thickness in ventilated patients.
PubMed 文献 · J Intensive Care · 2022-08-19
一句话结论在机械通气患者中,超声呼气末膈肌厚度(Tdi)<1.7 mm 对组织学膈肌萎缩(CSA<2851 μm²)有较高阳性预测值(96%),但正常或增高的 Tdi 不能排除萎缩。

本研究在35例通气器官捐献者和5例通气对照者中,同时进行膈肌活检免疫组化测定纤维横截面积(CSA)和超声测量呼气末膈肌厚度(Tdi),以对照组中位数作为阈值。结果显示捐献者 CSA 和 Tdi 均低于对照组,所有捐献者 CSA 均低于阈值,但仅74% Tdi 低于阈值。以 Tdi<1.7 mm 预测 CSA<2851 μm² 的萎缩,敏感度73%、特异度67%、阳性预测值96%、阴性预测值17%。结论认为 Tdi 降低是诊断萎缩的良好工具,但正常或增高的 Tdi 不能排除萎缩,两者不应视为同义词。

要点

  • 在35例通气器官捐献者中,所有捐献者活检 CSA 均低于对照组阈值(CSA<2851 μm²),但仅74%超声 Tdi 低于对照组阈值。
  • 超声 Tdi<1.7 mm 预测组织学膈肌萎缩(CSA<2851 μm²)的敏感度73%、特异度67%、阳性预测值96%、阴性预测值17%。
  • 正常或增高的 Tdi 不能排除膈肌萎缩,Tdi 与 CSA 不应视为同义词。
  • 研究纳入35例通气器官捐献者和5例通气对照者,两组基础特征无差异。
  • 两位超声观察者间的一致性在本研究中进行了评估。

适用人群与场景

  • 通气器官捐献者(35例)和通气对照者(5例)。
  • 纳入者接受膈肌活检和膈肌超声检查。

诊断标准与关键阈值

  • 组织学膈肌萎缩定义为膈肌纤维横截面积(CSA)<2851 μm²(以对照组CSA中位数作为阈值)。
  • 超声呼气末膈肌厚度(Tdi)降低定义为 Tdi<1.7 mm(以对照组Tdi中位数作为阈值)。

研究设计与关键结果

  • 研究类型为在通气器官捐献者和通气对照者中进行的膈肌活检与超声对照研究,共纳入35例通气器官捐献者和5例通气对照者,两组基础特征无差异。
  • 捐献者组 CSA 和 Tdi 均低于对照组。
  • 所有捐献者 CSA 均低于对照组阈值,但仅74%的捐献者 Tdi 低于对照组阈值。
  • 以 Tdi<1.7 mm 预测 CSA<2851 μm² 的膈肌萎缩,敏感度73%、特异度67%、阳性预测值96%、阴性预测值17%。
  • 研究评估了两位超声观察者之间的一致性。

证据类型、等级与局限

  • 证据类型:在通气器官捐献者和通气对照者中进行的活检与超声对照研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,超声 Tdi 降低是诊断膈肌萎缩的良好工具,但正常或增高的 Tdi 不能排除萎缩,Tdi 与 CSA 不应视为同义词。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Diaphragm fiber atrophy has been evidenced after short periods of mechanical ventilation (MV) and related to critical illness-associated diaphragm weakness. Atrophy is described as a decrease in diaphragm fiber cross-sectional area (CSA) in human diaphragm biopsy, but human samples are still difficult to obtain in clinics. In recent years, ultrasound has become a useful tool in intensive care to evaluate diaphragm anatomy. The present study aimed to evaluate the ability of diaphragm expiratory thickness (Tdi) measured by ultrasound to predict diaphragm atrophy, defined by a decrease in diaphragm fiber CSA obtained through diaphragm biopsy (the gold standard technique) in ventilated patients.

METHODS: Diaphragm biopsies and diaphragm ultrasound were performed in ventilated donors and in control subjects. Demographic variables, comorbidities, severity on admission, treatment, laboratory test results and evolution variables were evaluated. Immunohistochemical analysis to determine CSA and ultrasound measurements of Tdi at end-expiration were performed, and median values of the control group were used as thresholds to determine agreement between them in further analysis. Sensitivity, specificity, and positive and negative predictive values of an ultrasound Tdi cutoff for detecting histologic atrophy were calculated. Agreement between two ultrasound observers was also assessed.

RESULTS: Thirty-five ventilated organ donors and 5 ventilated controls were included, without differences in basic characteristics. CSA and Tdi were lower in donors than in controls. All donors presented lower CSA, but only 74% lower Tdi regarding control group thresholds. The cut-off value for lower diaphragm expiratory thickness (Tdi < 1.7 mm) presented a sensitivity of 73%, a specificity of 67%, a positive predictive value of 96% and a negative predictive value of 17% for determining the presence of diaphragm atrophy (CSA < 2851 μm2).

CONCLUSIONS: Diaphragm atrophy and thickness reduction is associated to MV. While a lower Tdi in diaphragm ultrasound is a good tool for diagnosing atrophy, normal or increased Tdi cannot rule atrophy out showing that both parameters should not be considered as synonymous.

来源:J Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Dot I, Pérez-Terán P, Francés A, et al. Association between histological diaphragm atrophy and ultrasound diaphragm expiratory thickness in ventilated patients. J Intensive Care. 2022. PMID: 35986366. doi:10.1186/s40560-022-00632-5

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。