液体负荷后毛细血管再充盈时间的动力学变化
本研究为三级教学医院的前瞻性观察性研究,先在40例危重患者中评估指尖毛细血管再充盈时间(CRT)的重复测量精度,组内相关系数为99.5%(95%CI [99.3, 99.8]),将CRT变化大于0.2秒定义为显著。随后在29例脓毒症患者中监测液体负荷期间的指尖CRT,在30分钟内每2分钟测量一次(15分钟内输注500 mL晶体液)。23例为有反应者(液体负荷后30分钟CRT下降大于0.2秒),6例为无反应者;有反应者中CRT在开始输注后6-8分钟显著下降,10-12分钟达最大改善(-0.7 [-0.3; -0.9]秒)并维持至30分钟;CRT变化与基线CRT显著相关(R=0.39,P=0.05)。
要点
- 在29例脓毒症患者中,15分钟内输注500 mL晶体液后,有反应者指尖CRT在6-8分钟即显著下降,10-12分钟达最大改善(-0.7 [-0.3; -0.9]秒),并维持至30分钟。
- CRT重复测量精度极佳,40例危重患者的组内相关系数为99.5%(95%CI [99.3, 99.8]),CRT变化大于0.2秒被视为显著。
- 液体负荷后30分钟CRT下降大于0.2秒定义为有反应,29例脓毒症患者中23例有反应、6例无反应。
- CRT变化与基线CRT测量值显著相关(R=0.39,P=0.05)。
- 研究人群病情较重:中位SOFA评分7 [5-9],中位SAPS II评分57 [45-72],ICU死亡率为24%。
适用人群与场景
- 脓毒症患者,在入住ICU后24小时内进行容量扩张时监测指尖CRT。
- 重复测量精度评估在40例危重患者中进行。
诊断标准与关键阈值
- CRT变化大于0.2秒被视为显著。
- 有反应者定义为液体负荷后30分钟CRT下降大于0.2秒。
处置流程与药物剂量
- 在15分钟内输注500 mL晶体液进行容量扩张。
- 在液体输注开始后30分钟内每2分钟测量一次指尖CRT。
研究设计与关键结果
- 研究类型为前瞻性观察性研究,在三级教学医院进行;重复测量精度评估纳入40例危重患者,组内相关系数为99.5%(95%CI [99.3, 99.8])。
- 容量扩张期间CRT变化评估纳入29例脓毒症患者,中位SOFA评分7 [5-9],中位SAPS II评分57 [45-72],ICU死亡率为24%。
- 23例为有反应者(30分钟CRT下降大于0.2秒),6例为无反应者。
- 有反应者中,指尖CRT在开始晶体液输注后6-8分钟显著下降,10-12分钟达最大改善(-0.7 [-0.3; -0.9]秒),并维持至30分钟。
- CRT变化与基线CRT测量值显著相关(R=0.39,P=0.05)。
证据类型、等级与局限
- 证据类型:前瞻性观察性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在脓毒症患者液体负荷期间,可在开始输注后6-12分钟评估指尖CRT变化,以早期判断对容量扩张的反应。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Capillary refill time (CRT) is a valuable tool for triage and to guide resuscitation. However, little is known about CRT kinetics after fluid infusion.
METHODS: We conducted a prospective observational study in a tertiary teaching hospital. First, we analyzed the intra-observer variability of CRT. Next, we monitored fingertip CRT in sepsis patients during volume expansion within the first 24 h of ICU admission. Fingertip CRT was measured every 2 min during 30 min following crystalloid infusion (500 mL over 15 min).
RESULTS: First, the accuracy of repetitive fingertip CRT measurements was evaluated on 40 critically ill patients. Reproducibility was excellent, with an intra-class correlation coefficient of 99.5% (CI 95% [99.3, 99.8]). A CRT variation larger than 0.2 s was considered as significant. Next, variations of CRT during volume expansion were evaluated on 29 septic patients; median SOFA score was 7 [5-9], median SAPS II was 57 [45-72], and ICU mortality rate was 24%. Twenty-three patients were responders as defined by a CRT decrease > 0.2 s at 30 min after volume expansion, and 6 were non-responders. Among responders, we observed that fingertip CRT quickly improved with a significant decrease at 6-8 min after start of crystalloid infusion, the maximal improvement being observed after 10-12 min (-0.7 [-0.3;-0.9] s) and maintained at 30 min. CRT variations significantly correlated with baseline CRT measurements (R = 0.39, P = 0.05).
CONCLUSIONS: CRT quickly improved during volume expansion with a significant decrease 6-8 min after start of fluid infusion and a maximal drop at 10-12 min.
参考来源
- Raia L, Gabarre P, Bonny V, et al. Kinetics of capillary refill time after fluid challenge. Ann Intensive Care. 2022. PMID: 35962860. doi:10.1186/s13613-022-01049-x
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。