文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

退伍军人健康管理局2013-19年普通病房内科和外科住院患者脉搏血氧计的种族偏倚与可重复性:多中心回顾性队列研究

Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort study.
PubMed 文献 · BMJ · 2022-07-06
一句话结论普通病房住院患者中,SpO2≥92%时黑种人隐匿性低氧血症概率高于白种人(19.6% vs 15.6%,P<0.001),可能限制黑种人获得氧疗等支持。

该多中心回顾性队列研究利用美国退伍军人健康管理局2013至2019年普通病房内科和外科住院患者的电子病历,评估不同种族间脉搏血氧计(SpO2)与动脉血气氧饱和度(SaO2)的测量差异。共识别30 039对10分钟内完成的SpO2-SaO2读数,以隐匿性低氧血症(SpO2≥92%而SaO2<88%)为主要结局。SpO2≥92%时,隐匿性低氧血症未调整概率白种人为15.6%(95%CI 15.0%至16.1%),黑种人为19.6%(18.6%至20.6%,对比白种人P<0.001,调整模型P值相似),西班牙裔或拉丁裔为16.2%(14.4%至18.1%,对比白种人P=0.53,调整模型P<0.05)。作者认为这一差异可能限制黑种人获得补充氧气及其他更密集的支持和治疗。

要点

  • 普通病房住院患者SpO2≥92%时,隐匿性低氧血症(SaO2<88%)未调整概率黑种人19.6%(95%CI 18.6%至20.6%)高于白种人15.6%(15.0%至16.1%),P<0.001,调整模型P值相似。
  • 西班牙裔或拉丁裔患者隐匿性低氧血症概率为16.2%(14.4%至18.1%),对比白种人P=0.53,调整模型P<0.05。
  • 将SpO2-SaO2配对限制在5分钟内和2分钟内,结果保持一致。
  • 白种人初次SpO2-SaO2配对饱和度差异很小时,后续SpO2为92%的配对读数出现SaO2<88%的概率为2.7%(95%CI -0.1%至5.5%),黑种人该概率更高,为12.9%(-3.3%至29.0%)。
  • 作者认为黑种人与白种人之间隐匿性低氧血症的差异可能限制黑种人获得补充氧气及其他更密集的支持和治疗。

适用人群与场景

  • 美国退伍军人健康管理局医疗中心普通病房(内科和外科)的成人住院患者,非重症监护患者。
  • 研究时段为2013至2019年。

诊断标准与关键阈值

  • 隐匿性低氧血症定义:动脉血氧饱和度(SaO2)<88%,而脉搏血氧计(SpO2)读数≥92%。
  • SpO2-SaO2配对要求两次读数在10分钟内完成;敏感性分析限制在5分钟内和2分钟内。

研究设计与关键结果

  • 研究设计为多中心回顾性队列研究,使用退伍军人健康管理局2013至2019年普通病房内科和外科住院患者的电子病历。
  • 共识别30 039对10分钟内完成的SpO2-SaO2读数;非西班牙裔白种人21 918对(73.0%),非西班牙裔黑种人6498对(21.6%),西班牙裔或拉丁裔1623对(5.4%)。
  • SpO2≥92%时,隐匿性低氧血症未调整概率:白种人15.6%(95%CI 15.0%至16.1%),黑种人19.6%(18.6%至20.6%)(对比白种人P<0.001,调整模型P值相似),西班牙裔或拉丁裔16.2%(14.4%至18.1%)(对比白种人P=0.53,调整模型P<0.05)。
  • 将SpO2-SaO2配对限制在5分钟内和2分钟内,结果保持一致。
  • 白种人初次SpO2-SaO2配对饱和度差异很小时,后续SpO2为92%的配对读数出现SaO2<88%的概率为2.7%(95%CI -0.1%至5.5%);黑种人该概率为12.9%(-3.3%至29.0%)。

证据类型、等级与局限

  • 证据类型:多中心回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,黑种人与白种人之间隐匿性低氧血症的差异可能限制黑种人获得补充氧气及其他更密集的支持和治疗。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate measurement discrepancies by race between pulse oximetry and arterial oxygen saturation (as measured in arterial blood gas) among inpatients not in intensive care.

DESIGN: Multicenter, retrospective cohort study using electronic medical records from general care medical and surgical inpatients.

SETTING: Veteran Health Administration, a national and racially diverse integrated health system in the United States, from 2013 to 2019.

PARTICIPANTS: Adult inpatients in general care (medical and surgical), in Veteran Health Administration medical centers.

MAIN OUTCOMES MEASURES: Occult hypoxemia (defined as arterial blood oxygen saturation (SaO2) of <88% despite a pulse oximetry (SpO2) reading of ≥92%), and whether rates of occult hypoxemia varied by race and ethnic origin.

RESULTS: A total of 30 039 pairs of SpO2-SaO2 readings made within 10 minutes of each other were identified during the study. These pairs were predominantly among non-Hispanic white (21 918 (73.0%)) patients; non-Hispanic black patients and Hispanic or Latino patients accounted for 6498 (21.6%) and 1623 (5.4%) pairs in the sample, respectively. Among SpO2 values greater or equal to 92%, unadjusted probabilities of occult hypoxemia were 15.6% (95% confidence interval 15.0% to 16.1%) in white patients, 19.6% (18.6% to 20.6%) in black patients (P<0.001 v white patients, with similar P values in adjusted models), and 16.2% (14.4% to 18.1%) in Hispanic or Latino patients (P=0.53 v white patients, P<0.05 in adjusted models). This result was consistent in SpO2-SaO2 pairs restricted to occur within 5 minutes and 2 minutes. In white patients, an initial SpO2-SaO2 pair with little difference in saturation was associated with a 2.7% (95% confidence interval -0.1% to 5.5%) probability of SaO2 <88% on a later paired SpO2-SaO2 reading showing an SpO2 of 92%, but black patients had a higher probability (12.9% (-3.3% to 29.0%)).

CONCLUSIONS: In general care inpatient settings across the Veterans Health Administration where paired readings of arterial blood gas (SaO2) and pulse oximetry (SpO2) were obtained, black patients had higher odds than white patients of having occult hypoxemia noted on arterial blood gas but not detected by pulse oximetry. This difference could limit access to supplemental oxygen and other more intensive support and treatments for black patients.

来源:BMJ,查看原文。版权归原作者所有。

参考来源

  1. Valbuena VSM, Seelye S, Sjoding MW, et al. Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort study. BMJ. 2022. PMID: 35793817. doi:10.1136/bmj-2021-069775

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。