潮气量挑战预测俯卧位急性呼吸窘迫综合征患者的前负荷反应性
本研究为单中心前瞻性研究,纳入58例俯卧位通气的ARDS患者,潮气量6 mL/kg,用跨肺热稀释监测,测量潮气量挑战(TVC,6→8 mL/kg持续1分钟)前后PPV变化(ΔPPV TVC6-8),以Trendelenburg动作CI变化≥8%且呼气末闭塞(8 mL/kg)CI变化≥5%定义前负荷反应性。共分析84组测量,42组存在前负荷反应性。ΔPPV TVC6-8≥3.5%预测前负荷反应性的AUROC为0.94±0.03(敏感度98%,特异度86%),优于基线PPV(0.85±0.05;p=0.047)。在基线PPV不确定(≥4%且<11%)的56组中,ΔPPV TVC6-8≥3.5%仍可可靠评估(AUROC 0.91±0.05,敏感度97%,特异度81%;p<0.01 vs 基线PPV)。
要点
- 俯卧位ARDS患者潮气量6 mL/kg通气时,将潮气量升至8 mL/kg持续1分钟,PPV绝对变化≥3.5%可预测前负荷反应性(AUROC 0.94±0.03,敏感度98%,特异度86%)。
- 基线PPV处于不确定区间(≥4%且<11%)的56组中,ΔPPV TVC6-8≥3.5%仍可靠(AUROC 0.91±0.05,敏感度97%,特异度81%;p<0.01 vs 基线PPV)。
- ΔPPV TVC6-8≥3.5%的预测能力优于基线PPV(AUROC 0.94±0.03 vs 0.85±0.05;p=0.047)。
- 该方法无需测量心输出量,可在俯卧位低潮气量通气条件下床旁评估前负荷反应性。
- 纳入患者俯卧位时间11(2-14)小时,去甲肾上腺素使用率83%、剂量0.25(0.15-0.42)µg/kg/min,PEEP 14(11-16)cmH2O,驱动压12(10-17)cmH2O,呼吸系统顺应性32(22-40)mL/cmH2O。
适用人群与场景
- 俯卧位通气的ARDS患者,潮气量6 mL/kg,经跨肺热稀释装置监测,收治于25张床位的大学医院ICU。
- 纳入时俯卧位时间11(2-14)小时;俯卧位前PaO2/FiO2为104±27 mmHg。
诊断标准与关键阈值
- 前负荷反应性定义:Trendelenburg动作期间心脏指数变化(ΔCITREND)≥8%且呼气末闭塞(8 mL/kg潮气量)期间心脏指数变化(ΔCI EEO8)≥5%。
- 前负荷无反应性定义:ΔCITREND<8%且ΔCI EEO8<5%。
- 基线PPV不确定区间:≥4%且<11%。
- 潮气量挑战:潮气量从6 mL/kg增至8 mL/kg持续1分钟,测PPV绝对变化(ΔPPV TVC6-8),阈值≥3.5%。
处置流程与药物剂量
- 在俯卧位、潮气量6 mL/kg通气下记录基线PPV。
- 将潮气量从6 mL/kg升至8 mL/kg持续1分钟,测量PPV变化(ΔPPV TVC6-8)。
- ΔPPV TVC6-8≥3.5%判定为前负荷反应性(敏感度98%,特异度86%);基线PPV在≥4%且<11%时该阈值仍可靠(敏感度97%,特异度81%)。
研究设计与关键结果
- 单中心前瞻性研究,25张床位ICU,纳入58例俯卧位ARDS患者,共分析84组测量。
- 纳入时去甲肾上腺素使用率83%,剂量0.25(0.15-0.42)µg/kg/min;PEEP 14(11-16)cmH2O;驱动压12(10-17)cmH2O;呼吸系统顺应性32(22-40)mL/cmH2O。
- 84组中42组存在前负荷反应性。
- ΔPPV TVC6-8≥3.5%预测前负荷反应性AUROC 0.94±0.03(敏感度98%,特异度86%),优于基线PPV的0.85±0.05(p=0.047)。
- 基线PPV不确定(≥4%且<11%)的56组中,ΔPPV TVC6-8≥3.5%的AUROC为0.91±0.05(敏感度97%,特异度81%;p<0.01 vs 基线PPV)。
证据类型、等级与局限
- 证据类型:单中心前瞻性研究。
- 试验注册:ClinicalTrials.gov NCT04457739,2020年6月30日注册,回顾性注册。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在俯卧位低潮气量通气的ARDS患者中,可通过1分钟潮气量挑战(6→8 mL/kg)观察PPV绝对变化≥3.5%来评估前负荷反应性,无需心输出量测量。
- 基线PPV落在≥4%且<11%的不确定区间时,潮气量挑战后的ΔPPV仍可提供可靠判断。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Prone position is frequently used in patients with acute respiratory distress syndrome (ARDS), especially during the Coronavirus disease 2019 pandemic. Our study investigated the ability of pulse pressure variation (PPV) and its changes during a tidal volume challenge (TVC) to assess preload responsiveness in ARDS patients under prone position.
METHODS: This was a prospective study conducted in a 25-bed intensive care unit at a university hospital. We included patients with ARDS under prone position, ventilated with 6 mL/kg tidal volume and monitored by a transpulmonary thermodilution device. We measured PPV and its changes during a TVC (ΔPPV TVC6-8) after increasing the tidal volume from 6 to 8 mL/kg for one minute. Changes in cardiac index (CI) during a Trendelenburg maneuver (ΔCITREND) and during end-expiratory occlusion (EEO) at 8 mL/kg tidal volume (ΔCI EEO8) were recorded. Preload responsiveness was defined by both ΔCITREND ≥ 8% and ΔCI EEO8 ≥ 5%. Preload unresponsiveness was defined by both ΔCITREND < 8% and ΔCI EEO8 < 5%.
RESULTS: Eighty-four sets of measurements were analyzed in 58 patients. Before prone positioning, the ratio of partial pressure of arterial oxygen to fraction of inspired oxygen was 104 ± 27 mmHg. At the inclusion time, patients were under prone position for 11 (2-14) hours. Norepinephrine was administered in 83% of cases with a dose of 0.25 (0.15-0.42) µg/kg/min. The positive end-expiratory pressure was 14 (11-16) cmH2O. The driving pressure was 12 (10-17) cmH2O, and the respiratory system compliance was 32 (22-40) mL/cmH2O. Preload responsiveness was detected in 42 cases. An absolute change in PPV ≥ 3.5% during a TVC assessed preload responsiveness with an area under the receiver operating characteristics (AUROC) curve of 0.94 ± 0.03 (sensitivity: 98%, specificity: 86%) better than that of baseline PPV (0.85 ± 0.05; p = 0.047). In the 56 cases where baseline PPV was inconclusive (≥ 4% and < 11%), ΔPPV TVC6-8 ≥ 3.5% still enabled to reliably assess preload responsiveness (AUROC: 0.91 ± 0.05, sensitivity: 97%, specificity: 81%; p < 0.01 vs. baseline PPV).
CONCLUSION: In patients with ARDS under low tidal volume ventilation during prone position, the changes in PPV during a TVC can reliably assess preload responsiveness without the need for cardiac output measurements.
TRIAL REGISTRATION: ClinicalTrials.gov (NCT04457739). Registered 30 June 2020 -Retrospectively registered, https://clinicaltrials.gov/ct2/show/record/NCT04457739.
参考来源
- Shi R, Ayed S, Moretto F, et al. Tidal volume challenge to predict preload responsiveness in patients with acute respiratory distress syndrome under prone position. Crit Care. 2022. PMID: 35850771. doi:10.1186/s13054-022-04087-w
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。