呼气末正压对急性呼吸窘迫综合征区域通气-灌注失匹配的影响
该研究纳入15例中重度ARDS患者,随机顺序施加5和15 cmH2O两个PEEP水平,用电阻抗断层成像评估三个重力区域通气-灌注失匹配,用复张-膨胀比法测量可复张性。结果显示高PEEP使非依赖区达正常通气-灌注比值的通气增加(p=0.018)、高通气-灌注比值的通气减少(p=0.023);中间区低通气-灌注比值的通气和灌注均减少(p=0.006和p=0.011)、正常通气-灌注比值的灌注增加(p=0.003);依赖区无通气区域血流百分比减少(p=0.041)。区域失匹配改善与肺可复张性和区域潮气量变化相关,提示床旁可复张性测量可能有助于判断PEEP对通气-灌注匹配的益处。
要点
- 中重度ARDS患者PEEP 15 vs 5 cmH2O:非依赖区达正常通气-灌注比值的通气增加(p=0.018),高通气-灌注比值的通气减少(p=0.023)。
- 中间区PEEP 15 cmH2O时低通气-灌注比值的通气和灌注均减少(p=0.006和p=0.011),正常通气-灌注比值的灌注增加(p=0.003)。
- 依赖区PEEP 15 cmH2O时流经无通气区域的血流百分比减少(p=0.041)。
- 区域通气-灌注失匹配改善与肺可复张性及区域潮气量变化相关,床旁可复张性测量与失匹配改善相关。
适用人群与场景
- 15例中重度急性呼吸窘迫综合征(ARDS)患者。
处置流程与药物剂量
- 以随机顺序施加两个PEEP水平:5和15 cmH2O。
- 每个PEEP水平下用电阻抗断层成像评估通气-灌注失匹配。
- 用复张-膨胀比法测量两个PEEP水平之间的可复张性。
研究设计与关键结果
- 研究类型:在15例中重度ARDS患者中随机顺序施加两个PEEP水平(5和15 cmH2O)的生理学研究。
- 非依赖区:较高PEEP时达正常通气-灌注比值的通气增加(p=0.018),高通气-灌注比值的通气减少(p=0.023)。
- 中间区:PEEP 15 cmH2O时低通气-灌注比值的通气减少(p=0.006)、低通气-灌注比值的灌注减少(p=0.011),正常通气-灌注比值的灌注增加(p=0.003)。
- 依赖区:流经无通气区域的血流百分比减少(p=0.041)。
- 区域通气-灌注失匹配改善与肺可复张性和区域潮气量变化相关。
证据类型、等级与局限
- 证据类型:生理学研究(15例中重度ARDS患者)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在ARDS患者中较高PEEP优化通气(非依赖区)和灌注(中间和依赖区)的分布。
- 作者认为,床旁可复张性测量与通气-灌注失匹配改善相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
PURPOSE: In the acute respiratory distress syndrome (ARDS), decreasing Ventilation-Perfusion [Formula: see text] mismatch might enhance lung protection. We investigated the regional effects of higher Positive End Expiratory Pressure (PEEP) on [Formula: see text] mismatch and their correlation with recruitability. We aimed to verify whether PEEP improves regional [Formula: see text] mismatch, and to study the underlying mechanisms.
METHODS: In fifteen patients with moderate and severe ARDS, two PEEP levels (5 and 15 cmH2O) were applied in random order. [Formula: see text] mismatch was assessed by Electrical Impedance Tomography at each PEEP. Percentage of ventilation and perfusion reaching different ranges of [Formula: see text] ratios were analyzed in 3 gravitational lung regions, leading to precise assessment of their distribution throughout different [Formula: see text] mismatch compartments. Recruitability between the two PEEP levels was measured by the recruitment-to-inflation ratio method.
RESULTS: In the non-dependent region, at higher PEEP, ventilation reaching the normal [Formula: see text] compartment (p = 0.018) increased, while it decreased in the high [Formula: see text] one (p = 0.023). In the middle region, at PEEP 15 cmH2O, ventilation and perfusion to the low [Formula: see text] compartment decreased (p = 0.006 and p = 0.011) and perfusion to normal [Formula: see text] increased (p = 0.003). In the dependent lung, the percentage of blood flowing through the non-ventilated compartment decreased (p = 0.041). Regional [Formula: see text] mismatch improvement was correlated to lung recruitability and changes in regional tidal volume.
CONCLUSIONS: In patients with ARDS, higher PEEP optimizes the distribution of both ventilation (in the non-dependent areas) and perfusion (in the middle and dependent lung). Bedside measure of recruitability is associated with improved [Formula: see text] mismatch.
参考来源
- Pavlovsky B, Pesenti A, Spinelli E, et al. Effects of PEEP on regional ventilation-perfusion mismatch in the acute respiratory distress syndrome. Crit Care. 2022. PMID: 35818077. doi:10.1186/s13054-022-04085-y
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。