单手胸外按压技术中垂直按压对儿童心肺复苏效果的影响
本研究为前瞻性随机交叉模拟试验,42名医生在儿童模型上分别采用传统单手胸外按压(试验1)或垂直单手胸外按压(试验2)进行2分钟单人CPR。结果显示试验2的平均胸外按压深度和达标深度百分比均显著高于试验1(平均深度54.0 mm vs 49.0 mm,P<0.001;达标深度99.0% vs 52.0%,P<0.001),平均按压力量亦显著更高(25.7 kg vs 24.5 kg,P<0.001),通气参数无显著差异。作者认为垂直单手胸外按压的优势源于按压力量的提升。
要点
- 在儿童模型2分钟单人CPR中,垂直单手胸外按压的平均胸外按压深度为54.0 mm(IQR 48.5-56.0),高于传统单手胸外按压的49.0 mm(IQR 40.0-54.0),P<0.001。
- 垂直单手胸外按压的达标胸外按压深度百分比为99.0%(IQR 36.3-100.0),高于传统单手胸外按压的52.0%(IQR 0.0-98.0),P<0.001。
- 垂直单手胸外按压的平均按压力量为25.7 kg ± 4.4,高于传统单手胸外按压的24.5 kg ± 4.2,P<0.001。
- 两种技术的通气参数无显著差异。
- 作者认为,垂直单手胸外按压可提供更深且更达标的胸外按压深度,其优势源于按压力量的提升。
适用人群与场景
- 42名医生在儿童模型上实施2分钟单人CPR的模拟场景。
研究设计与关键结果
- 前瞻性随机交叉模拟试验,42名医生在儿童模型上分别采用传统单手胸外按压(试验1)或垂直单手胸外按压(试验2)进行2分钟单人CPR。
- 平均胸外按压深度:试验2为54.0 mm(IQR 48.5-56.0),试验1为49.0 mm(IQR 40.0-54.0),试验2显著高于试验1,P<0.001。
- 达标胸外按压深度百分比:试验2为99.0%(IQR 36.3-100.0),试验1为52.0%(IQR 0.0-98.0),试验2显著高于试验1,P<0.001。
- 平均按压力量:垂直单手胸外按压为25.7 kg ± 4.4,传统单手胸外按压为24.5 kg ± 4.2,垂直单手胸外按压显著更高,P<0.001。
- 通气参数在试验1与试验2之间无显著差异。
证据类型、等级与局限
- 证据类型:前瞻性随机交叉模拟试验。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,垂直单手胸外按压较传统单手胸外按压可提供更深且更达标的胸外按压深度,其优势源于按压力量的提升。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: The posture of the rescuer while performing the one-handed chest compression (OHCC) has not yet been evaluated. This study aimed to investigate the effect of vertical compression during pediatric cardiopulmonary resuscitation (CPR) using the OHCC technique.
METHODS: This was a prospective randomized crossover simulation trial. A total of 42 medical doctors conducted a 2-min single-rescuer CPR using the conventional OHCC (Test 1) or vertical OHCC (Test 2) technique on a pediatric manikin. The chest compression and ventilation parameters were measured in real time during the experiments using sensors embedded in the manikin. In addition, the compression force of each technique was measured using a force plate.
RESULTS: The average and adequate chest compression depth (CCD) were significantly higher in Test 2 than in Test 1 (average depth: 54.0 mm (interquartile range [IQR]: 48.5-56.0) in Test 2 vs. 49.0 mm (IQR: 40.0-54.0) in Test 1, P < 0.001; adequate depth: 99.0% (IQR: 36.3-100.0) in Test 2 vs. 52.0% (IQR: 0.0-98.0) in Test 1, P < 0.001). The average force of compression was also significantly higher in vertical OHCC than that in conventional OHCC (25.7 kg ± 4.4 in vertical OHCC vs. 24.5 kg ± 4.2 in conventional OHCC, P < 0.001). The ventilation parameters were not significantly different between Tests 1 and 2.
CONCLUSIONS: The vertical OHCC could provide a deeper and more adequate CCD compared with the conventional OHCC, and the advantages of the vertical OHCC originate from the superiority of the compression force.
参考来源
- Oh JH, Noh H, Lee JG, et al. Effects of vertical compression during pediatric cardiopulmonary resuscitation using the one-handed chest compression technique. Am J Emerg Med. 2022. PMID: 35772224. doi:10.1016/j.ajem.2022.06.044
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。