文献速递复苏、休克与脓毒症重症综合管理与镇静镇痛

预测重症监护室血流动力学不稳定性的机器学习模型的外部验证

External validation of a machine learning model to predict hemodynamic instability in intensive care unit.
PubMed 文献 · Crit Care · 2022-07-14
一句话结论HSI模型在亚洲ICU外部验证中区分度可接受(AUROC 0.76),但低估稳定患者风险;阈值0.7可提前>5 h识别95%不稳定患者。

该回顾性研究在台北荣民总医院2010年1月1日至2020年3月31日收治的15,967例成人ICU患者中独立验证血流动力学稳定性指数(HSI)模型,血流动力学不稳定定义为使用正性肌力药、血管升压药、大量液体治疗和/或输血,发生3053例(患病率19%)。HSI的AUROC为0.76(95%CI 0.75-0.77),显著优于休克指数(0.7;95%CI 0.69-0.71)和收缩压(0.69;95%CI 0.68-0.70)。选取0.7为阈值时,HSI预测了全部3053例接受血流动力学干预患者中的72%,特异性67%;95%的不稳定患者可提前5小时以上被识别。作者结论认为HSI区分度可接受,但在外部队列中低估了稳定患者的风险。

要点

  • HSI模型外部验证AUROC 0.76(95%CI 0.75-0.77),优于休克指数0.7(95%CI 0.69-0.71)和收缩压0.69(95%CI 0.68-0.70)。
  • 阈值0.7时HSI预测72%的3053例接受血流动力学干预患者,特异性67%。
  • 时间变化分析显示HSI在干预前24小时内仍显著优于单一指标。
  • 95%的不稳定患者可提前5小时以上被识别。
  • HSI区分度可接受,但作者指出其在外部队列中低估稳定患者的风险。

适用人群与场景

  • 台北荣民总医院2010年1月1日至2020年3月31日收治的15,967例ICU患者,年龄20岁或以上(不包含20岁),ICU停留时间超过6小时。
  • 血流动力学不稳定组3053例(患病率19%),在ICU期间至少接受一种干预(正性肌力药、血管升压药、大量液体治疗和/或输血)。

诊断标准与关键阈值

  • 血流动力学不稳定定义:使用正性肌力药、血管升压药、大量液体治疗和/或输血。
  • HSI阈值选为0.7,以高灵敏度、可接受特异性为原则设定报警。

研究设计与关键结果

  • 回顾性研究,纳入15,967例ICU患者,血流动力学不稳定3053例(患病率19%),HSI的AUROC为0.76(95%CI 0.75-0.77),显著优于休克指数(0.7;95%CI 0.69-0.71)和收缩压(0.69;95%CI 0.68-0.70)。
  • 阈值0.7时,HSI预测了3053例中72%接受血流动力学干预的患者,特异性67%。
  • 时间变化分析显示HSI在干预前24小时内仍显著优于单一指标。
  • 95%的不稳定患者可提前5小时以上被识别。

证据类型、等级与局限

  • 回顾性外部验证研究。
  • 局限:作者结论指出HSI在外部队列中低估稳定患者的风险。

对床旁实践的改变

  • 作者认为HSI区分度可接受,但低估稳定患者风险,在床旁用于预测血流动力学不稳定时需注意这一局限。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Early prediction model of hemodynamic instability has the potential to improve the critical care, whereas limited external validation on the generalizability. We aimed to independently validate the Hemodynamic Stability Index (HSI), a multi-parameter machine learning model, in predicting hemodynamic instability in Asian patients.

METHOD: Hemodynamic instability was marked by using inotropic, vasopressor, significant fluid therapy, and/or blood transfusions. This retrospective study included among 15,967 ICU patients who aged 20 years or older (not included 20 years) and stayed in ICU for more than 6 h admitted to Taipei Veteran General Hospital (TPEVGH) between January 1, 2010, and March 31, 2020, of whom hemodynamic instability occurred in 3053 patients (prevalence = 19%). These patients in unstable group received at least one intervention during their ICU stays, and the HSI score of both stable and unstable group was calculated in every hour before intervention. The model performance was assessed using the area under the receiver operating characteristic curve (AUROC) and was compared to single indicators like systolic blood pressure (SBP) and shock index. The hemodynamic instability alarm was set by selecting optimal threshold with high sensitivity, acceptable specificity, and lead time before intervention was calculated to indicate when patients were firstly identified as high risk of hemodynamic instability.

RESULTS: The AUROC of HSI was 0.76 (95% CI, 0.75-0.77), which performed significantly better than shock Index (0.7; 95% CI, 0.69-0.71) and SBP (0.69; 95% CI, 0.68-0.70). By selecting 0.7 as a threshold, HSI predicted 72% of all 3053 patients who received hemodynamic interventions with 67% in specificity. Time-varying results also showed that HSI score significantly outperformed single indicators even up to 24 h before intervention. And 95% unstable patients can be identified more than 5 h in advance.

CONCLUSIONS: The HSI has acceptable discrimination but underestimates the risk of stable patients in predicting the onset of hemodynamic instability in an external cohort.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Dung-Hung C, Cong T, Zeyu J, et al. External validation of a machine learning model to predict hemodynamic instability in intensive care unit. Crit Care. 2022. PMID: 35836294. doi:10.1186/s13054-022-04088-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。