文献速递复苏、休克与脓毒症

心肺复苏中气道开放指数的研究

Investigating the Airway Opening Index during cardiopulmonary resuscitation.
PubMed 文献 · Resuscitation · 2022-07-16
一句话结论在307例院外心脏骤停病例中,自主循环恢复者的ΔETCO2中位数显著高于未恢复者(7.3 mmHg vs 4.8 mmHg,p<0.001),AOI各方法间差异显著但预测价值需进一步研究。

该回顾性研究分析了2019年西雅图307例院外心脏骤停病例,基于ETCO2及胸阻抗波形标注插管和CPR,开发了四种基于峰值ETCO2和胸外按压期间ETCO2振荡(ΔETCO2)的气道开放指数(AOI)计算方法,并评估自动化计算的可行性及不同方法间AOI差异。四种方法计算的全病例AOI中位数分别为28.0%、20.6%、18.3%、22.4%(p<0.001)。自主循环恢复(ROSC)者的ΔETCO2中位数显著高于未恢复者(7.3 mmHg vs 4.8 mmHg,p<0.001),AOI在各方法下ROSC者均较高但未达统计学显著。作者认为需进一步研究AOI预测院外心脏骤停结局的能力及其能否改善复苏救治。

要点

  • 在307例院外心脏骤停病例中,ROSC者ΔETCO2中位数为7.3 mmHg,显著高于未ROSC者的4.8 mmHg(p<0.001)。
  • 四种方法计算的全病例AOI中位数分别为28.0%、20.6%、18.3%、22.4%,方法间差异显著(p<0.001)。
  • ROSC者在所有AOI计算方法下中位数均高于未ROSC者,但差异未达统计学显著。
  • 研究评估了自动化计算ΔETCO2和AOI的可行性,并采用非参数检验比较不同方法(α=0.05)。
  • 作者认为需进一步研究以明确AOI预测院外心脏骤停结局的能力及能否改善复苏救治。

适用人群与场景

  • 2019年西雅图307例院外心脏骤停(OHCA)病例的回顾性数据。

研究设计与关键结果

  • 研究类型:回顾性研究,样本量307例院外心脏骤停病例,数据来自2019年美国华盛顿州西雅图。
  • 方法:基于峰值ETCO2和胸外按压期间ETCO2振荡(ΔETCO2)开发了四种AOI计算方法,评估自动化计算ΔETCO2和AOI的可行性,使用非参数检验比较方法间差异(α=0.05)。
  • 主要结果:四种方法计算的全病例AOI中位数[四分位距]分别为28.0%[17.9-45.5%]、20.6%[13.0-36.6%]、18.3%[11.4-30.4%]、22.4%[12.8-38.5%](p<0.001)。
  • ROSC者ΔETCO2中位数[四分位距]为7.3 mmHg[4.5-13.6 mmHg],显著高于未ROSC者的4.8 mmHg[2.6-9.1 mmHg](p<0.001)。
  • ROSC者在所有AOI计算方法下中位数均高于未ROSC者,但差异未达统计学显著。

证据类型、等级与局限

  • 证据类型:回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Chest compressions during CPR induce oscillations in capnography (ETCO2) waveforms. Studies suggest ETCO2 oscillation characteristics are associated with intrathoracic airflow dependent on airway patency. Oscillations can be quantified by the Airway Opening Index (AOI). We sought to evaluate multiple methods of computing AOI and their association with return of spontaneous circulation (ROSC).

METHODS: We conducted a retrospective study of 307 out-of-hospital cardiac arrest (OHCA) cases in Seattle, WA during 2019. ETCO2 and chest impedance waveforms were annotated for the presence of intubation and CPR. We developed four methods for computing AOI based on peak ETCO2 and the oscillations in ETCO2 during chest compressions (ΔETCO2). We examined the feasibility of automating ΔETCO2 and AOI calculation and evaluated differences in AOI across the methods using nonparametric testing (α = 0.05).

RESULTS: Median [interquartile range] AOI across all cases using Methods 1-4 was 28.0 % [17.9-45.5 %], 20.6 % [13.0-36.6 %], 18.3 % [11.4-30.4 %], and 22.4 % [12.8-38.5 %], respectively (p < 0.001). Cases with ROSC had a higher median AOI than those without ROSC across all methods, though not statistically significant. Cases with ROSC had a significantly higher median [interquartile range] ΔETCO2 of 7.3 mmHg [4.5-13.6 mmHg] compared to those without ROSC (4.8 mmHg [2.6-9.1 mmHg], p < 0.001).

CONCLUSION: We calculated AOI using four proposed methods resulting in significantly different AOI. Additionally, AOI and ΔETCO2 were larger in cases achieving ROSC. Further investigation is required to characterize AOI's ability to predict OHCA outcomes, and whether this information can improve resuscitation care.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Bhandari S, Coult J, Counts CR, et al. Investigating the Airway Opening Index during cardiopulmonary resuscitation. Resuscitation. 2022. PMID: 35850376. doi:10.1016/j.resuscitation.2022.07.015

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。