文献速递儿科与产科急症

医院网站上中级新生儿病房描述的准确性与完整性

Accuracy and Completeness of Intermediate-Level Nursery Descriptions on Hospital Websites.
PubMed 文献 · JAMA Netw Open · 2022-06-01
一句话结论在10个有监管的大州中,医院网站对level II新生儿病房的描述不完整者占39.2%(95%CI 33.3%-45.3%)、不准确者占24.6%(95%CI 19.6%-30.2%),可能误导家长和转诊医生。

这项横断面研究比较了2019年活产数最高的10个有level II监管的州中,医院网页对level II病房能力的描述与州级认定是否一致,纳入2021年5月有活跃网站的医院。结果显示,39.2%(95%CI 33.3%-45.3%)的医院描述不完整,24.6%(95%CI 19.6%-30.2%)描述不准确;其中25.4%(95%CI 20.3%-31.0%)的医院直接称其为「新生儿重症监护病房(NICU)」而未加限定,9.3%(95%CI 6.3%-13.5%)声称提供最先进的新生儿护理或救治病情最重的新生儿。作者认为,这些缺陷可能误导家长、临床医生和公众对医院能否收治患病新生儿的判断,并提出了重要的伦理问题。

要点

  • 在10个有level II监管的大州,医院网页对level II病房的描述不完整者占39.2%(95%CI 33.3%-45.3%)、不准确者占24.6%(95%CI 19.6%-30.2%)。
  • 25.4%(95%CI 20.3%-31.0%)的医院将level II病房不加限定地称为「新生儿重症监护病房(NICU)」,9.3%(95%CI 6.3%-13.5%)声称提供最先进护理或救治病情最重的新生儿。
  • 不完整描述中,2.6%(95%CI 1.1%-5.3%)的医院未提及高级护理单元,22.0%(95%CI 17.2%-27.5%)仅标明level II而未提供进一步描述。
  • 不准确描述中,3.0%(95%CI 1.3%-6.0%)的医院将病房标为level III,1.5%(95%CI 0.4%-3.8%)标为level II和III。
  • 各州之间描述不完整和不准确的比例存在较大差异。

适用人群与场景

  • 纳入2019年活产数最高的10个有level II监管的州(排除无level II监管的州)中,截至2021年5月有活跃网站的医院level II病房。

研究设计与关键结果

  • 研究类型:横断面研究,比较10个大州医院网页对level II病房能力的描述与州级认定。
  • 28个州无新生儿病房级别监管;在10个有监管的大州中,level II病房网页描述不完整者占39.2%(95%CI 33.3%-45.3%),不准确者占24.6%(95%CI 19.6%-30.2%)。
  • 不完整描述中:2.6%(95%CI 1.1%-5.3%)的医院未提及高级护理单元;22.0%(95%CI 17.2%-27.5%)标明了level II但未提供进一步描述。
  • 不准确描述中:25.4%(95%CI 20.3%-31.0%)的医院不加限定地使用「新生儿重症监护病房」或「NICU」;9.3%(95%CI 6.3%-13.5%)声称提供最先进新生儿护理或救治病情最重的新生儿;3.0%(95%CI 1.3%-6.0%)标为level III;1.5%(95%CI 0.4%-3.8%)标为level II和III。
  • 各州之间描述不完整和不准确的比例存在较大差异。

证据类型、等级与局限

  • 证据类型:横断面研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,医院网页对中级新生儿病房描述不完整和不准确的情况常见,这些缺陷可能误导家长、临床医生和公众对医院能否收治患病新生儿的判断,并提出了重要的伦理问题。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

IMPORTANCE: Birth at hospitals with an appropriate level of neonatal intensive care units is associated with better neonatal outcomes. The primary sources for information about hospital neonatal unit levels for prospective parents, referring physicians, and the public are hospital websites, but the accuracy of neonatal unit capacity is unclear.

OBJECTIVE: To determine if hospital websites accurately report the capabilities of intermediate (ie, level II) units, which are intended for care of newborns with low to moderate illness levels or the stabilization of newborns prior to transfer.

DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional study compared descriptions of level II unit capabilities on hospital web pages in 10 large states with their respective state-level designation. Analyzed units were located in the 10 states with the highest number of live births in 2019 (excluding states with no level II regulations) and had active websites as of May 2021.

MAIN OUTCOMES AND MEASURES: Hospital websites were assessed for whether there was any mention of the unit, the description of the unit was provided, the unit was identified as a level III or both levels II and III, the terms "neonatal intensive care unit" or "NICU" were used without indicating limits in care available or newborn acuity, or the unit was claimed to provide the most advanced level of care.

RESULTS: A total 28 states had no regulation of nursery unit levels; in the 10 large, regulated states, web descriptions of level II units were incomplete for 39.2% of hospitals (95% CI, 33.3%-45.3%) and inaccurate for 24.6% (95% CI, 19.6%-30.2%). Within incomplete descriptions, 2.6% (95% CI, 1.1%-5.3%) of hospitals did not mention an advanced care unit and 22.0% (95% CI, 17.2%-27.5%) identified a level II unit without providing further description. Within inaccurate descriptions, 25.4% (95% CI, 20.3%-31.0%) of hospitals described the unit as a "neonatal intensive care unit" or "NICU" without any qualification and 9.3% (95% CI, 6.3%-13.5%) claimed that the unit provided the most advanced neonatal care or care to the sickest newborns; 3.0% of hospitals (95% CI, 1.3%-6.0%) stated that their unit was level III and 1.5% (95% CI, 0.4%-3.8%) as level II and III. Across states there was substantial variation in rates of incompleteness and inaccuracy.

CONCLUSIONS AND RELEVANCE: Incomplete and inaccurate hospital web descriptions of intermediate newborn care units are common. These deficits can mislead parents, clinicians, and the public about the appropriateness of a hospital for sick newborns, which raises important ethical questions.

来源:JAMA Netw Open,查看原文。版权归原作者所有。

参考来源

  1. Goodman DC, Price TJ, Braun D, et al. Accuracy and Completeness of Intermediate-Level Nursery Descriptions on Hospital Websites. JAMA Netw Open. 2022. PMID: 35666499. doi:10.1001/jamanetworkopen.2022.15596

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。