PEEK颅骨修补患者床旁超声监测脑室大小的初步可行性经验
本研究为前瞻性初步机构系列,纳入8例颅脑创伤去骨瓣减压后行聚醚醚酮(PEEK)颅骨修补的患者,利用PEEK对回声的通透性,以床旁经颅超声测量脑室形态参数,并与同日CT测量比较。超声图像质量高、颅内解剖可清晰评估;侧脑室额角间距(IFH)和第三脑室直径(TV)在分流术前(IFH rho=0.92,p=0.01;TV rho=0.99,p=0.008)和分流术后(IFH rho=0.95,p=0.03;TV rho=0.97,p=0.03)均与CT强相关。超声与CT平均误差率分别为术前IFH 1.77±0.91 mm、术前TV 0.65±0.27 mm、术后IFH 2.18±0.82 mm、术后TV 0.48±0.21 mm。作者认为经颅超声可能简化此类患者脑室大小随访与管理,并可能拓展PEEK作为颅内探查与分流功能监测窗口的获益。
要点
- 8例颅脑创伤去骨瓣减压后PEEK颅骨修补患者,经修补窗床旁超声图像质量高,颅内解剖可清晰评估。
- 侧脑室额角间距(IFH)超声与同日CT强相关:分流术前rho=0.92(p=0.01),分流术后rho=0.95(p=0.03)。
- 第三脑室直径(TV)超声与同日CT强相关:分流术前rho=0.99(p=0.008),分流术后rho=0.97(p=0.03)。
- 超声与CT平均误差率:术前IFH 1.77±0.91 mm、术前TV 0.65±0.27 mm、术后IFH 2.18±0.82 mm、术后TV 0.48±0.21 mm。
- 作者认为经颅超声可能简化PEEK颅骨修补患者脑室大小的随访与管理,并可能作为监测分流功能的窗口。
适用人群与场景
- 颅脑创伤后去骨瓣减压、并已行聚醚醚酮(PEEK)颅骨修补的患者(本研究8例,前瞻性评估)。
研究设计与关键结果
- 研究类型:前瞻性初步机构系列,8例颅脑创伤去骨瓣减压后行PEEK颅骨修补患者。
- 超声测量与同日CT扫描数据比较,比较脑室形态参数。
- 经PEEK颅骨修补窗的超声图像质量高,颅内解剖可清晰评估;超声与CT测量之间观察到强相关。
- 分流术前:IFH rho=0.92(p=0.01),TV rho=0.99(p=0.008)。
- 分流术后:IFH rho=0.95(p=0.03),TV rho=0.97(p=0.03)。
- 超声与CT平均误差率:术前IFH 1.77±0.91 mm,术前TV 0.65±0.27 mm,术后IFH 2.18±0.82 mm,术后TV 0.48±0.21 mm。
证据类型、等级与局限
- 证据类型:前瞻性初步机构系列(小样本,8例)。
- 局限:原文报告为小系列(small series),结果为初步结果。
对床旁实践的改变
- 作者认为经颅超声可能简化PEEK颅骨修补患者脑室大小的随访与管理。
- 作者认为初步结果可能拓展PEEK的潜在获益:不仅是有效的颅骨重建材料,在选定临床条件下还可作为探查颅内内容、监测脑室大小与分流功能的可靠窗口。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Posttraumatic hydrocephalus is a known complication after traumatic brain injury, particularly affecting patients undergoing decompressive craniectomy. Posttraumatic hydrocephalus monitoring in these patients represents a common issue in neurosurgical practice. Patients require periodical assessments by means of computed tomography (CT) scans. This study presents a preliminary institutional series in which ultrasound was used as a bedside imaging technique to monitor ventricular size in patients harboring a polyetheretherketone (PEEK) cranioplasty. Exploiting the PEEK cranioplasty permeability to echoes, we evaluated the feasibility of this bedside imaging method in monitoring hydrocephalus evolution, determining effects of ventriculo-peritoneal shunt, and excluding complications.
METHODS: Eight patients with traumatic brain injury harboring PEEK cranioplasty following decompressive craniectomy were prospectively evaluated. Ultrasound measurements were compared with CT scan data taken the same day, and ventricular morphometry parameters were compared.
RESULTS: Ultrasound images through the PEEK cranioplasty were of high quality and intracranial anatomy was distinctly evaluated. A strong correlation was observed between ultrasound and CT measurements. Concerning distance between lateral ventricles frontal horns (IFH) and the diameter of the third ventricle (TV), we found a strong correlation between transcranial sonography and CT measurements in preventriculoperitoneal shunt (rho = 0.92 and p = 0.01 for IFH; rho = 0.99 and p = 0.008 for TV) and in postventriculoperitoneal shunt examinations (rho = 0.95 and p = 0.03 for IFH; rho = 0.97 and p = 0.03 for TV). The mean error rate between transcranial sonography and CT scan was 1.77 ± 0.91 mm for preoperative IFH, 0.65 ± 0.27 mm for preoperative TV, 2.18 ± 0.82 mm for postoperative IFH, and 0.48 ± 0.21 mm for postoperative TV.
CONCLUSIONS: Transcranial ultrasound could represent a simplification of the follow-up and management of ventricular size of patients undergoing PEEK cranioplasty. Even if this is a small series, our preliminary results could widen the potential benefits of PEEK, not only as effective material for cranial reconstruction but also, in selected clinical conditions, as a reliable window to explore intracranial content and to monitor ventricular sizes and shunt functioning.
参考来源
- Signorelli F, Della Pepa GM, Marziali G, et al. Bedside Ultrasound for Ventricular Size Monitoring in Patients with PEEK Cranioplasty: A Preliminary Experience of Technical Feasibility in Neurotrauma Setting. Neurocrit Care. 2022. PMID: 35761126. doi:10.1007/s12028-022-01544-w
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。