文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

驱动压导向通气较预测体质量导向通气降低急性呼吸窘迫综合征患者的机械功

Driving pressure-guided ventilation decreases the mechanical power compared to predicted body weight-guided ventilation in the Acute Respiratory Distress Syndrome.
PubMed 文献 · Crit Care · 2022-06-20
一句话结论中重度ARDS患者以驱动压12–14 cm H2O为目标调整潮气量,可使机械功从31.5 J/min降至28.8 J/min(P<0.001),但临床获益尚待试验评估。

该前瞻性研究纳入51例中重度ARDS成人患者,呼气末正压由主管医师设定并在研究期间保持不变。先以预测体质量6 ml/kg为目标调整潮气量(PBW导向通气),再在4–10 ml/kg预测体质量范围内调整潮气量使驱动压达12–14 cm H2O,并将呼吸频率在12–40次/分范围内重新调整至呼气末二氧化碳回到基线值(驱动压导向通气)。结果显示,从PBW导向转为驱动压导向通气后,潮气量从6.1 mL/kg预测体质量[5.9–6.2]升至7.7 mL/kg预测体质量[6.2–8.7],呼吸频率从29次/分[26–32]降至21次/分[16–28](所有比较P<0.001);机械功从31.5 J/min[28–35.7]显著降至28.8 J/min[24.6–32.6](P<0.001),相对降低7%[0–16];驱动压导向通气下氧合指数升高、通气比值下降。作者认为,该生理学观察是否伴随临床获益尚需临床试验评估。

要点

  • 中重度ARDS患者以驱动压12–14 cm H2O为目标调整潮气量,在51例中50例可行。
  • 从PBW导向转为驱动压导向通气后,潮气量由6.1 mL/kg预测体质量[5.9–6.2]升至7.7 mL/kg预测体质量[6.2–8.7],呼吸频率由29次/分[26–32]降至21次/分[16–28](P<0.001)。
  • 驱动压导向通气使机械功由31.5 J/min[28–35.7]降至28.8 J/min[24.6–32.6](P<0.001),相对降低7%[0–16]。
  • PBW导向通气时,驱动压已处于驱动压导向目标范围内的仅5例(10%),高于目标范围9例(18%),低于目标范围36例(72%)。
  • 驱动压导向通气下氧合指数升高、通气比值下降。

适用人群与场景

  • 成人中重度急性呼吸窘迫综合征(ARDS)患者,研究于2019年12月至2021年5月前瞻性纳入51例。

诊断标准与关键阈值

  • 驱动压导向通气目标:驱动压12–14 cm H2O,潮气量调整范围4–10 mL/kg预测体质量,呼吸频率调整范围12–40次/分直至呼气末二氧化碳回到基线值。
  • PBW导向通气目标:潮气量6 mL/kg预测体质量。

处置流程与药物剂量

  • 呼气末正压由主管医师设定并在研究期间保持不变。
  • 先以预测体质量6 mL/kg为目标调整潮气量(PBW导向通气)。
  • 随后在4–10 mL/kg预测体质量范围内调整潮气量,使驱动压达12–14 cm H2O(驱动压导向通气)。
  • 再将呼吸频率在12–40次/分范围内重新调整,直至呼气末二氧化碳回到基线值。

研究设计与关键结果

  • 前瞻性研究纳入51例成人中重度ARDS患者;驱动压导向通气除1例外均可行。
  • PBW导向通气时驱动压已处于目标范围5例(10%),高于目标范围9例(18%),低于目标范围36例(72%)。
  • 从PBW导向转为驱动压导向通气后,潮气量从6.1 mL/kg预测体质量[5.9–6.2]升至7.7 mL/kg预测体质量[6.2–8.7],呼吸频率从29次/分[26–32]降至21次/分[16–28](所有比较P<0.001)。
  • 驱动压导向通气使机械功从31.5 J/min[28–35.7]降至28.8 J/min[24.6–32.6](P<0.001),相对降低7%[0–16]。
  • 驱动压导向通气下氧合指数(PaO2/FiO2)升高,通气比值下降。

证据类型、等级与局限

  • 证据类型:前瞻性生理学研究。
  • 局限:原文未报告局限性,但作者在结论中指出该生理学观察是否伴随临床获益尚需临床试验评估。

对床旁实践的改变

  • 作者认为,与传统PBW导向通气相比,以驱动压12–14 cm H2O为目标的驱动压导向通气需在90%的患者中改变潮气量,并显著降低机械功;该生理学观察是否伴随临床获益尚需临床试验评估。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Whether targeting the driving pressure (∆P) when adjusting the tidal volume in mechanically ventilated patients with the acute respiratory distress syndrome (ARDS) may decrease the risk of ventilator-induced lung injury remains a matter of research. In this study, we assessed the effect of a ∆P-guided ventilation on the mechanical power.

METHODS: We prospectively included adult patients with moderate-to-severe ARDS. Positive end expiratory pressure was set by the attending physician and kept constant during the study. Tidal volume was first adjusted to target 6 ml/kg of predicted body weight (PBW-guided ventilation) and subsequently modified within a range from 4 to 10 ml/kg PBW to target a ∆P between 12 and 14 cm H2O. The respiratory rate was then re-adjusted within a range from 12 to 40 breaths/min until EtCO2 returned to its baseline value (∆P-guided ventilation). Mechanical power was computed at each step.

RESULTS: Fifty-one patients were included between December 2019 and May 2021. ∆P-guided ventilation was feasible in all but one patient. The ∆P during PBW-guided ventilation was already within the target range of ∆P-guided ventilation in five (10%) patients, above in nine (18%) and below in 36 (72%). The change from PBW- to ∆P-guided ventilation was thus accompanied by an overall increase in tidal volume from 6.1 mL/kg PBW [5.9-6.2] to 7.7 ml/kg PBW [6.2-8.7], while respiratory rate was decreased from 29 breaths/min [26-32] to 21 breaths/min [16-28] (p < 0.001 for all comparisons). ∆P-guided ventilation was accompanied by a significant decrease in mechanical power from 31.5 J/min [28-35.7] to 28.8 J/min [24.6-32.6] (p < 0.001), representing a relative decrease of 7% [0-16]. With ∆P-guided ventilation, the PaO2/FiO2 ratio increased and the ventilatory ratio decreased.

CONCLUSION: As compared to a conventional PBW-guided ventilation, a ∆P-guided ventilation strategy targeting a ∆P between 12 and 14 cm H2O required to change the tidal volume in 90% of the patients. Such ∆P-guided ventilation significantly reduced the mechanical power. Whether this physiological observation could be associated with clinical benefit should be assessed in clinical trials.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Haudebourg AF, Tuffet S, Perier F, et al. Driving pressure-guided ventilation decreases the mechanical power compared to predicted body weight-guided ventilation in the Acute Respiratory Distress Syndrome. Crit Care. 2022. PMID: 35725498. doi:10.1186/s13054-022-04054-5

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。