早期累积液体平衡与COVID-19 ARDS患者有创通气成功脱机的关联:PRoVENT-COVID研究启示——一项全国多中心观察性队列分析
该研究分析荷兰22家医院2020年3月1日至2020年6月期间收治的650例确诊COVID-19合并ARDS的有创通气患者,按第3天累积液体平衡分为高、中、低三组,中位值分别为1.98 L(1.27-7.72 L)、0.78 L(0.26-1.27 L)和-0.35 L(-6.52-0.26 L)。以成功脱机为主要结局,采用Cox比例风险模型分析第3天累积液体平衡与脱机的关联。结果显示,第3天累积液体平衡越高,成功脱机概率越低(校正HR 0.86,95%CI 0.77-0.95,P=0.0047),敏感性分析结果相似。作者认为,较高的累积液体平衡与更长的通气时间相关,提示限制性液体管理可能有益。
要点
- 在650例COVID-19 ARDS有创通气患者中,第3天累积液体平衡越高,成功脱机概率越低(校正HR 0.86,95%CI 0.77-0.95,P=0.0047)。
- 第3天累积液体平衡高、中、低三组的中位值分别为1.98 L(1.27-7.72 L)、0.78 L(0.26-1.27 L)和-0.35 L(-6.52-0.26 L)。
- 敏感性分析(排除缺失数据和建模ARDS严重程度)显示与主要分析相似的结果。
- 作者认为,较高的累积液体平衡与更长的通气时间相关,提示限制性液体管理在这些患者中可能有益。
适用人群与场景
- 确诊COVID-19合并ARDS、需要有创通气、于2020年3月1日至2020年6月期间在荷兰22家医院收治的患者。
研究设计与关键结果
- 研究类型:全国多中心观察性队列分析(PRoVENT-COVID研究),纳入荷兰22家医院650例确诊COVID-19合并ARDS的有创通气患者。
- 主要结局:成功脱机,以第3天累积液体平衡为函数,采用Cox比例风险模型分析粗关联和校正关联。
- 第3天累积液体平衡高、中、低三组的中位值分别为1.98 L(1.27-7.72 L)、0.78 L(0.26-1.27 L)和-0.35 L(-6.52-0.26 L)。
- 第3天累积液体平衡越高,成功脱机概率越低(校正HR 0.86,95%CI 0.77-0.95,P=0.0047)。
- 敏感性分析(排除缺失数据和建模ARDS严重程度)显示与主要分析相似的结果。
证据类型、等级与局限
- 证据类型:全国多中心观察性队列分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,在COVID-19 ARDS有创通气患者中,较高的累积液体平衡与更长的通气时间相关,提示限制性液体管理可能有益。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Increasing evidence indicates the potential benefits of restricted fluid management in critically ill patients. Evidence lacks on the optimal fluid management strategy for invasively ventilated COVID-19 patients. We hypothesized that the cumulative fluid balance would affect the successful liberation of invasive ventilation in COVID-19 patients with acute respiratory distress syndrome (ARDS).
METHODS: We analyzed data from the multicenter observational 'PRactice of VENTilation in COVID-19 patients' study. Patients with confirmed COVID-19 and ARDS who required invasive ventilation during the first 3 months of the international outbreak (March 1, 2020, to June 2020) across 22 hospitals in the Netherlands were included. The primary outcome was successful liberation of invasive ventilation, modeled as a function of day 3 cumulative fluid balance using Cox proportional hazards models, using the crude and the adjusted association. Sensitivity analyses without missing data and modeling ARDS severity were performed.
RESULTS: Among 650 patients, three groups were identified. Patients in the higher, intermediate, and lower groups had a median cumulative fluid balance of 1.98 L (1.27-7.72 L), 0.78 L (0.26-1.27 L), and - 0.35 L (- 6.52-0.26 L), respectively. Higher day 3 cumulative fluid balance was significantly associated with a lower probability of successful ventilation liberation (adjusted hazard ratio 0.86, 95% CI 0.77-0.95, P = 0.0047). Sensitivity analyses showed similar results.
CONCLUSIONS: In a cohort of invasively ventilated patients with COVID-19 and ARDS, a higher cumulative fluid balance was associated with a longer ventilation duration, indicating that restricted fluid management in these patients may be beneficial. Trial registration Clinicaltrials.gov ( NCT04346342 ); Date of registration: April 15, 2020.
参考来源
- Ahuja S, de Grooth HJ, Paulus F, et al. Association between early cumulative fluid balance and successful liberation from invasive ventilation in COVID-19 ARDS patients - insights from the PRoVENT-COVID study: a national, multicenter, observational cohort analysis. Crit Care. 2022. PMID: 35650616. doi:10.1186/s13054-022-04023-y
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。