文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

基于机器学习的胸部X线预测机械通气患者拔管失败的价值

The Contribution of Chest X-Ray to Predict Extubation Failure in Mechanically Ventilated Patients Using Machine Learning-Based Algorithms.
PubMed 文献 · Crit Care Explor · 2022-06-10
一句话结论在预测机械通气患者拔管失败时,将拔管前胸部X线加入其他临床预测因素并未显著提高预测能力。

本研究为回顾性队列研究,基于Medical Information Mart for Intensive Care IV数据库,纳入1,066例≥18岁、机械通气并在自主呼吸试验后拔管的患者,其中132例(12%)发生拔管失败(拔管后48小时内再插管或死亡)。研究者基于深度学习和机器学习构建了仅用快速浅呼吸指数(RSBI)、RSBI+胸部X线、全部临床预测因素(不含胸部X线)、全部临床预测因素+胸部X线四种模型。在测试数据中,RSBI+胸部X线与仅用RSBI的c统计量无显著差异(0.56 vs 0.56,p=0.95);全部临床预测因素+胸部X线与不含胸部X线的c统计量也无显著差异(0.71 vs 0.70,p=0.12)。SHapley Additive exPlanations值显示,胸部X线对预测能力的贡献可能小于其他预测因素(如机械通气时长、无法遵从指令和心率)。结论认为,将胸部X线加入其他临床预测因素并未显著改善拔管失败的预测能力。

要点

  • 在1,066例机械通气拔管患者中,132例(12%)发生拔管失败,定义为拔管后48小时内再插管或死亡。
  • RSBI+胸部X线模型与仅用RSBI模型的c统计量无显著差异(0.56 vs 0.56,p=0.95)。
  • 全部临床预测因素+胸部X线模型与不含胸部X线的全部临床预测因素模型的c统计量无显著差异(0.71 vs 0.70,p=0.12)。
  • SHapley Additive exPlanations值提示,胸部X线对预测能力的贡献可能小于其他预测因素(如机械通气时长、无法遵从指令和心率)。
  • 作者认为,将胸部X线加入其他临床预测因素并未显著提高拔管失败的预测能力。

适用人群与场景

  • 年龄≥18岁、接受机械通气并在自主呼吸试验后拔管的患者。

诊断标准与关键阈值

  • 拔管失败定义为拔管后48小时内再插管或死亡。

研究设计与关键结果

  • 研究类型为回顾性队列研究,数据来自Medical Information Mart for Intensive Care IV数据库,纳入1,066例机械通气拔管患者,其中132例(12%)发生拔管失败。
  • 基于深度学习和机器学习构建四种预测模型:仅用RSBI、RSBI+胸部X线、全部临床预测因素(不含胸部X线)、全部临床预测因素+胸部X线。
  • RSBI+胸部X线模型与仅用RSBI模型的c统计量无显著差异(0.56 vs 0.56,p=0.95)。
  • 全部临床预测因素+胸部X线模型与不含胸部X线的全部临床预测因素模型的c统计量无显著差异(0.71 vs 0.70,p=0.12)。
  • SHapley Additive exPlanations值显示,胸部X线对预测能力的贡献可能小于其他预测因素(如机械通气时长、无法遵从指令和心率)。

证据类型、等级与局限

  • 证据类型:回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,将胸部X线加入其他临床预测因素并未显著提高拔管失败的预测能力。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the contribution of a preextubation chest X-ray (CXR) to identify the risk of extubation failure in mechanically ventilated patients.

DESIGN: Retrospective cohort study.

SETTINGS: ICUs in a tertiary center (the Medical Information Mart for Intensive Care IV database).

PATIENTS: Patients greater than or equal to 18 years old who were mechanically ventilated and extubated after a spontaneous breathing trial.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN RESULTS: Among 1,066 mechanically ventilated patients, 132 patients (12%) experienced extubation failure, defined as reintubation or death within 48 hours of extubation. To predict extubation failure, we developed the following models based on deep learning (EfficientNet) and machine learning (LightGBM) with the training data: 1) model using only the rapid-shallow breathing index (RSBI), 2) model using RSBI and CXR, 3) model using all candidate clinical predictors (i.e., patient demographics, vital signs, laboratory values, and ventilator settings) other than CXR, and 4) model using all candidate clinical predictors with CXR. We compared the predictive abilities between models with the test data to investigate the predictive contribution of CXR. The predictive ability of the model using CXR as well as RSBI was not significantly higher than that of the model using only RSBI (c-statistics, 0.56 vs 0.56; p = 0.95). The predictive ability of the model using clinical predictors with CXR was not significantly higher than that of the model using all clinical predictors other than CXR (c-statistics, 0.71 vs 0.70; p = 0.12). Based on SHapley Additive exPlanations values to interpret the model using all clinical predictors with CXR, CXR was less likely to contribute to the predictive ability than other predictors (e.g., duration of mechanical ventilation, inability to follow commands, and heart rate).

CONCLUSIONS: Adding CXR to a set of other clinical predictors in our prediction model did not significantly improve the predictive ability of extubation failure in mechanically ventilated patients.

来源:Crit Care Explor,查看原文。版权归原作者所有。

参考来源

  1. Fukuchi K, Osawa I, Satake S, et al. The Contribution of Chest X-Ray to Predict Extubation Failure in Mechanically Ventilated Patients Using Machine Learning-Based Algorithms. Crit Care Explor. 2022. PMID: 35702351. doi:10.1097/CCE.0000000000000718

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。