文献速递心脑血管急症呼吸衰竭与机械通气重症综合管理与镇静镇痛

额面QRS/T夹角可预测COVID-19患者死亡率

Frontal QRS/T angle can predict mortality in COVID-19 patients.
PubMed 文献 · Am J Emerg Med · 2022-05-25
一句话结论COVID-19患者入院心电图额面QRS/T夹角>90°与院内死亡风险升高及需要机械通气相关。

这项回顾性多中心研究纳入327例COVID-19住院患者,入院时完成心电图并计算额面QRS/T夹角。按夹角>90°与≤90°分组,两组死亡率分别为67.8%与26.1%,需要机械通气比例分别为66.1%与29.9%。多变量分析中,心率、血氧饱和度、fQRS夹角、估算肾小球滤过率和C反应蛋白水平是死亡预测因素;夹角>90°组较≤90°组死亡风险单变量分析升高2.9倍、多变量分析升高1.6倍。作者认为宽fQRS夹角>90°是COVID-19患者院内死亡和需要机械通气的预测因素。

要点

  • 327例COVID-19住院患者中,119例需要机械通气,其中110例院内死亡。
  • fQRS夹角>90°组死亡率67.8%、需要机械通气66.1%,均高于≤90°组的26.1%和29.9%。
  • 多变量分析显示心率、血氧饱和度、fQRS夹角、估算肾小球滤过率和C反应蛋白水平是死亡预测因素。
  • fQRS夹角>90°组较≤90°组死亡风险单变量分析升高2.9倍、多变量分析升高1.6倍。
  • 作者认为宽fQRS夹角>90°是COVID-19患者院内死亡和需要机械通气的预测因素。

适用人群与场景

  • 327例COVID-19住院患者,入院时完成心电图并计算额面QRS/T夹角。

诊断标准与关键阈值

  • 按额面QRS/T夹角>90°与≤90°分为两组。

研究设计与关键结果

  • 回顾性多中心研究纳入327例COVID-19患者,入院时行心电图并计算额面QRS/T夹角。
  • 119例需要机械通气,其中110例院内死亡。
  • fQRS夹角>90°组死亡率67.8%、需要机械通气比例66.1%;fQRS夹角≤90°组死亡率26.1%、需要机械通气比例29.9%。
  • 多变量分析中,心率、血氧饱和度、fQRS夹角、估算肾小球滤过率和C反应蛋白水平是死亡的预测因素。
  • fQRS夹角>90°组较≤90°组死亡风险单变量分析升高2.9倍、多变量分析升高1.6倍。

证据类型、等级与局限

  • 证据类型:回顾性多中心研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,宽fQRS夹角>90°是COVID-19患者院内死亡和需要机械通气的预测因素。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

AIMS: The frontal QRS-T (fQRS) angle has been investigated in the general population, including healthy people and patients with heart failure. The fQRS angle can predict mortality due to myocarditis, ischaemic and non-ischaemic cardiomyopathies, idiopathic dilated cardiomyopathy, and chronic heart failure in the general population. Moreover, no studies to date have investigated fQRS angle in coronavirus disease 2019 (COVID-19) patients. Thus, the purpose of this retrospective multicentre study was to evaluate the fQRS angle of COVID-19 patients to predict in-hospital mortality and the need for mechanical ventilation.

METHODS AND RESULTS: An electrocardiogram was performed for 327 COVID-19 patients during admission, and the fQRS angle was calculated. Mechanical ventilation was needed in 119 patients; of them, 110 died in the hospital. The patients were divided into two groups according to an fQRs angle >90° versus an fQRS angle ≤90°. The percentages of mortality and the need for mechanical ventilation according to fQRS angle were 67.8% and 66.1%, respectively, in the fQRs >90° group and 26.1% and 29.9% in the fQRS ≤90°group. Heart rate, oxygen saturation, fQRS angle, estimated glomerular filtration rate, and C-reactive protein level were predictors of mortality on the multivariable analysis. The mortality risk increased 2.9-fold on the univariate analysis and 1.6-fold on the multivariate analysis for the fQRS >90° patient group versus the fQRS ≤90° group.

CONCLUSION: In conclusion, a wide fQRS angle >90° was a predictor of in-hospital mortality and associated with the need for mechanical ventilation among COVID-19 patients.

来源:Am J Emerg Med,查看原文。版权归原作者所有。

参考来源

  1. Gunduz R, Yildiz BS, Ozgur S, et al. Frontal QRS/T angle can predict mortality in COVID-19 patients. Am J Emerg Med. 2022. PMID: 35636045. doi:10.1016/j.ajem.2022.05.034

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。