机械通气撤机过程中呼吸困难与吸气肌肌电活动的关系
本研究纳入31例接受自主呼吸试验的机械通气患者,在试验开始和结束时用呼吸困难视觉模拟量表(Dyspnea-VAS)测量呼吸困难强度,同时用多电极鼻胃管连续测量膈肌肌电(EMGdi)、表面电极测量胸骨旁肌电(EMGpa)和鼻翼肌电(EMGan)。17例(45%)患者自主呼吸试验失败,失败者Dyspnea-VAS升高6(4‒8)cm,显著高于通过者的0(0‒1)cm(p=0.01),Dyspnea-VAS的受试者工作特征曲线下面积为0.909(0.786-1.032)。Dyspnea-VAS升高与EMGan升高显著相关(Rho=0.42 [0.04‒0.70],p<0.05),与EMGpa和EMGdi升高无显著相关。结论认为呼吸困难是自主呼吸试验失败的可靠标准,Dyspnea-VAS可作为自主呼吸试验的监测工具,且呼吸困难似乎与鼻翼肌电活动的关系比与膈肌更密切。
要点
- 17例(45%)患者自主呼吸试验失败,失败者Dyspnea-VAS升高6(4‒8)cm,通过者仅升高0(0‒1)cm(p=0.01)。
- Dyspnea-VAS预测自主呼吸试验失败的受试者工作特征曲线下面积为0.909(0.786-1.032)。
- Dyspnea-VAS升高与鼻翼肌电(EMGan)升高显著相关(Rho=0.42 [0.04‒0.70],p<0.05)。
- Dyspnea-VAS升高与胸骨旁肌电(EMGpa)升高无显著相关(Rho=-0.121 [-0.495 to -0.290],p=0.555)。
- Dyspnea-VAS升高与膈肌肌电(EMGdi)升高无显著相关(Rho=-0.26 [-0.68 to 0.28],p=0.289)。
适用人群与场景
- 接受机械通气并正在进行自主呼吸试验的患者,SAPS 2中位数53(37‒74),机械通气时间中位数6(3‒10)天。
诊断标准与关键阈值
- 自主呼吸试验失败判定:原文以Dyspnea-VAS在自主呼吸试验期间的升高作为失败标准,失败者升高6(4‒8)cm,通过者升高0(0‒1)cm。
- Dyspnea-VAS预测自主呼吸试验失败的受试者工作特征曲线下面积为0.909(0.786-1.032)。
处置流程与药物剂量
- 在30分钟自主呼吸试验开始和结束时用Dyspnea-VAS测量呼吸困难强度。
- 自主呼吸试验期间用多电极鼻胃管连续测量膈肌肌电(EMGdi),用表面电极测量胸骨旁肌电(EMGpa)和鼻翼肌电(EMGan),直至自主呼吸试验失败。
研究设计与关键结果
- 研究类型为观察性研究,纳入31例机械通气患者,17例(45%)自主呼吸试验失败。
- 自主呼吸试验失败者Dyspnea-VAS升高6(4‒8)cm,通过者升高0(0‒1)cm,组间比较p=0.01。
- Dyspnea-VAS的受试者工作特征曲线下面积为0.909(0.786-1.032)。
- Dyspnea-VAS升高与EMGan升高显著相关(Rho=0.42 [0.04‒0.70],p<0.05)。
- Dyspnea-VAS升高与EMGpa升高无显著相关(Rho=-0.121 [-0.495 to -0.290],p=0.555)。
- Dyspnea-VAS升高与EMGdi升高无显著相关(Rho=-0.26 [-0.68 to 0.28],p=0.289)。
证据类型、等级与局限
- 证据类型:观察性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为呼吸困难是自主呼吸试验失败的可靠标准,提示Dyspnea-VAS可作为自主呼吸试验的监测工具。
- 作者认为呼吸困难似乎与鼻翼肌电活动的关系比与膈肌更密切。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
RATIONALE: Dyspnea, a key symptom of acute respiratory failure, is not among the criteria for spontaneous breathing trial (SBT) failure. Here, we sought (1) to determine whether dyspnea is a reliable failure criterion for SBT failure; (2) to quantify the relationship between dyspnea and the respective electromyographic activity of the diaphragm (EMGdi), the parasternal (EMGpa) and the Alae nasi (EMGan).
METHODS: Mechanically ventilated patients undergoing an SBT were included. Dyspnea intensity was measured by the Dyspnea-Visual Analogic Scale (Dyspnea-VAS) at the initiation and end of the SBT. During the 30-min SBT or until SBT failure, the EMGdi was continuously measured with a multi-electrode nasogastric catheter and the EMGan and EMGpa with surface electrodes.
RESULTS: Thirty-one patients were included, SAPS 2 (median [interquartile range]) 53 (37‒74), mechanically ventilated for 6 (3‒10) days. Seventeen patients (45%) failed the SBT. The increase in Dyspnea-VAS along the SBT was higher in patients who failed (6 [4‒8] cm) than in those who passed (0 [0‒1] cm, p = 0.01). The area under the receiver operating characteristics curve for Dyspnea-VAS was 0.909 (0.786-1.032). The increase in Dyspnea-VAS was significantly correlated to the increase in EMGan (Rho = 0.42 [0.04‒0.70], p < 0.05), but not to the increase in EMGpa (Rho = - 0.121 [- 0.495 to - 0.290], p = 0.555) and EMGdi (Rho = - 0.26 [- 0.68 to 0.28], p = 0.289).
CONCLUSION: Dyspnea is a reliable criterion of SBT failure, suggesting that Dyspnea-VAS could be used as a monitoring tool of the SBT. In addition, dyspnea seems to be more closely related to the electromyographic activity of the Alae nasi than of the diaphragm.
参考来源
- Bureau C, Dres M, Morawiec E, et al. Dyspnea and the electromyographic activity of inspiratory muscles during weaning from mechanical ventilation. Ann Intensive Care. 2022. PMID: 35688999. doi:10.1186/s13613-022-01025-5
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。