文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

机械通气撤机过程中呼吸困难与吸气肌肌电活动的关系

Dyspnea and the electromyographic activity of inspiratory muscles during weaning from mechanical ventilation.
PubMed 文献 · Ann Intensive Care · 2022-06-10
一句话结论呼吸困难是自主呼吸试验失败的可靠标准,Dyspnea-VAS曲线下面积0.909,且呼吸困难与鼻翼肌电活动相关而非膈肌。

本研究纳入31例接受自主呼吸试验的机械通气患者,在试验开始和结束时用呼吸困难视觉模拟量表(Dyspnea-VAS)测量呼吸困难强度,同时用多电极鼻胃管连续测量膈肌肌电(EMGdi)、表面电极测量胸骨旁肌电(EMGpa)和鼻翼肌电(EMGan)。17例(45%)患者自主呼吸试验失败,失败者Dyspnea-VAS升高6(4‒8)cm,显著高于通过者的0(0‒1)cm(p=0.01),Dyspnea-VAS的受试者工作特征曲线下面积为0.909(0.786-1.032)。Dyspnea-VAS升高与EMGan升高显著相关(Rho=0.42 [0.04‒0.70],p<0.05),与EMGpa和EMGdi升高无显著相关。结论认为呼吸困难是自主呼吸试验失败的可靠标准,Dyspnea-VAS可作为自主呼吸试验的监测工具,且呼吸困难似乎与鼻翼肌电活动的关系比与膈肌更密切。

要点

  • 17例(45%)患者自主呼吸试验失败,失败者Dyspnea-VAS升高6(4‒8)cm,通过者仅升高0(0‒1)cm(p=0.01)。
  • Dyspnea-VAS预测自主呼吸试验失败的受试者工作特征曲线下面积为0.909(0.786-1.032)。
  • Dyspnea-VAS升高与鼻翼肌电(EMGan)升高显著相关(Rho=0.42 [0.04‒0.70],p<0.05)。
  • Dyspnea-VAS升高与胸骨旁肌电(EMGpa)升高无显著相关(Rho=-0.121 [-0.495 to -0.290],p=0.555)。
  • Dyspnea-VAS升高与膈肌肌电(EMGdi)升高无显著相关(Rho=-0.26 [-0.68 to 0.28],p=0.289)。

适用人群与场景

  • 接受机械通气并正在进行自主呼吸试验的患者,SAPS 2中位数53(37‒74),机械通气时间中位数6(3‒10)天。

诊断标准与关键阈值

  • 自主呼吸试验失败判定:原文以Dyspnea-VAS在自主呼吸试验期间的升高作为失败标准,失败者升高6(4‒8)cm,通过者升高0(0‒1)cm。
  • Dyspnea-VAS预测自主呼吸试验失败的受试者工作特征曲线下面积为0.909(0.786-1.032)。

处置流程与药物剂量

  • 在30分钟自主呼吸试验开始和结束时用Dyspnea-VAS测量呼吸困难强度。
  • 自主呼吸试验期间用多电极鼻胃管连续测量膈肌肌电(EMGdi),用表面电极测量胸骨旁肌电(EMGpa)和鼻翼肌电(EMGan),直至自主呼吸试验失败。

研究设计与关键结果

  • 研究类型为观察性研究,纳入31例机械通气患者,17例(45%)自主呼吸试验失败。
  • 自主呼吸试验失败者Dyspnea-VAS升高6(4‒8)cm,通过者升高0(0‒1)cm,组间比较p=0.01。
  • Dyspnea-VAS的受试者工作特征曲线下面积为0.909(0.786-1.032)。
  • Dyspnea-VAS升高与EMGan升高显著相关(Rho=0.42 [0.04‒0.70],p<0.05)。
  • Dyspnea-VAS升高与EMGpa升高无显著相关(Rho=-0.121 [-0.495 to -0.290],p=0.555)。
  • Dyspnea-VAS升高与EMGdi升高无显著相关(Rho=-0.26 [-0.68 to 0.28],p=0.289)。

证据类型、等级与局限

  • 证据类型:观察性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为呼吸困难是自主呼吸试验失败的可靠标准,提示Dyspnea-VAS可作为自主呼吸试验的监测工具。
  • 作者认为呼吸困难似乎与鼻翼肌电活动的关系比与膈肌更密切。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

RATIONALE: Dyspnea, a key symptom of acute respiratory failure, is not among the criteria for spontaneous breathing trial (SBT) failure. Here, we sought (1) to determine whether dyspnea is a reliable failure criterion for SBT failure; (2) to quantify the relationship between dyspnea and the respective electromyographic activity of the diaphragm (EMGdi), the parasternal (EMGpa) and the Alae nasi (EMGan).

METHODS: Mechanically ventilated patients undergoing an SBT were included. Dyspnea intensity was measured by the Dyspnea-Visual Analogic Scale (Dyspnea-VAS) at the initiation and end of the SBT. During the 30-min SBT or until SBT failure, the EMGdi was continuously measured with a multi-electrode nasogastric catheter and the EMGan and EMGpa with surface electrodes.

RESULTS: Thirty-one patients were included, SAPS 2 (median [interquartile range]) 53 (37‒74), mechanically ventilated for 6 (3‒10) days. Seventeen patients (45%) failed the SBT. The increase in Dyspnea-VAS along the SBT was higher in patients who failed (6 [4‒8] cm) than in those who passed (0 [0‒1] cm, p = 0.01). The area under the receiver operating characteristics curve for Dyspnea-VAS was 0.909 (0.786-1.032). The increase in Dyspnea-VAS was significantly correlated to the increase in EMGan (Rho = 0.42 [0.04‒0.70], p < 0.05), but not to the increase in EMGpa (Rho = - 0.121 [- 0.495 to - 0.290], p = 0.555) and EMGdi (Rho = - 0.26 [- 0.68 to 0.28], p = 0.289).

CONCLUSION: Dyspnea is a reliable criterion of SBT failure, suggesting that Dyspnea-VAS could be used as a monitoring tool of the SBT. In addition, dyspnea seems to be more closely related to the electromyographic activity of the Alae nasi than of the diaphragm.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Bureau C, Dres M, Morawiec E, et al. Dyspnea and the electromyographic activity of inspiratory muscles during weaning from mechanical ventilation. Ann Intensive Care. 2022. PMID: 35688999. doi:10.1186/s13613-022-01025-5

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。