文献速递重症综合管理与镇静镇痛复苏、休克与脓毒症

牛津急性疾病严重程度评分与简化急性生理评分Ⅱ对脓毒症患者院内死亡预测价值的比较:基于MIMIC-IV数据库的分析

[Comparison of the predictive value of the Oxford acute severity of illness score and simplified acute physiology score II for in-hospital mortality in intensive care unit patients with sepsis: an analysis based on MIMIC-IV database].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2022-01-01
一句话结论在ICU脓毒症患者中,OASIS评分对院内死亡的预测价值与SAPSⅡ评分相似(AUC 0.713 vs 0.716,P>0.05),且OASIS更简便。

该回顾性队列研究基于MIMIC-IV 0.4数据库,纳入11 098例首次入ICU的成人脓毒症患者(Sepsis-3标准,感染且入ICU 24小时内SOFA评分≥2),院内死亡2 320例,死亡率20.90%。死亡组年龄更大、ICU住院时间更长,血管活性药、镇静药、机械通气和肾脏替代治疗比例均更高(均P<0.01),OASIS评分和SAPSⅡ评分也更高(均P<0.01)。ROC曲线分析显示,OASIS评分与SAPSⅡ评分预测院内死亡的AUC分别为0.713(95%CI 0.701-0.725)和0.716(95%CI 0.704-0.728),Delong检验显示两者差异无统计学意义(P>0.05)。作者认为OASIS评分对脓毒症患者院内死亡有良好预测价值,与SAPSⅡ评分相似,且更简便、临床应用前景更广。

要点

  • 在11 098例ICU成人脓毒症患者中,院内死亡2 320例,死亡率20.90%。
  • 死亡组OASIS评分43(36, 49)vs 存活组35(29, 41),SAPSⅡ评分49(40, 60)vs 38(31, 47),均P<0.01。
  • OASIS评分预测院内死亡AUC 0.713(95%CI 0.701-0.725),SAPSⅡ评分AUC 0.716(95%CI 0.704-0.728)。
  • Delong检验显示两种评分系统AUC差异无统计学意义(P>0.05)。
  • 作者认为OASIS评分预测价值与SAPSⅡ评分相似,且更简便、临床应用前景更广。

适用人群与场景

  • 基于MIMIC-IV 0.4数据库,首次入ICU的成人脓毒症患者,符合Sepsis-3诊断标准(感染且入ICU 24小时内SOFA评分≥2)。

诊断标准与关键阈值

  • 脓毒症诊断采用Sepsis-3标准:感染且入ICU 24小时内SOFA评分≥2。

研究设计与关键结果

  • 回顾性队列研究,基于MIMIC-IV 0.4数据库,最终纳入11 098例成人ICU脓毒症患者,其中院内死亡2 320例、存活8 778例,死亡率20.90%。
  • 死亡组较存活组年龄更大[71(60, 81)岁 vs 67(56, 78)岁]、ICU住院时间更长[6.95(3.39, 13.07)天 vs 4.23(2.19, 9.73)天],血管活性药使用比例50.65%(1 175/2 320)vs 33.05%(2 901/8 778)、镇静药58.53%(1 358/2 320)vs 48.41%(4 249/8 778)、机械通气89.57%(2 078/2 320)vs 81.66%(7 168/8 778)、肾脏替代治疗11.98%(278/2 320)vs 6.57%(577/8 778),均P<0.01。
  • 死亡组OASIS评分43(36, 49)vs 存活组35(29, 41),SAPSⅡ评分49(40, 60)vs 38(31, 47),均P<0.01。
  • ROC曲线分析显示,OASIS评分预测院内死亡的AUC为0.713(95%CI 0.701-0.725),SAPSⅡ评分AUC为0.716(95%CI 0.704-0.728),Delong检验显示两者AUC差异无统计学意义(P>0.05)。

证据类型、等级与局限

  • 证据类型:基于MIMIC-IV 0.4数据库的回顾性队列研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为OASIS评分对脓毒症患者院内死亡有良好预测价值,与SAPSⅡ评分相似,且OASIS评分更简便、临床应用前景更广。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To compare the predictive value of Oxford acute severity of illness score (OASIS) and simplified acute physiology score II (SAPS II) for in-hospital mortality in intensive care unit (ICU) patients with sepsis.

METHODS: A retrospective cohort study was conducted using the data in the Medical Information Mart for Intensive Care-IV 0.4 (MIMIC-IV 0.4). Based on Sepsis-3 diagnostic criteria, the basic information of ICU adult sepsis patients with infection and sequential organ failure assessment (SOFA) score ≥ 2 within 24 hours of ICU admission admitted for the first time in the database was extracted, including gender, age, vasopressor drugs, sedative drugs, mechanical ventilation, renal replacement therapy, length of ICU stay, OASIS, SAPS II scores, etc. The primary outcome was in-hospital mortality. A receiver operator characteristic curve (ROC curve) was drawn, and the area under the ROC curve (AUC) was calculated to compare the prognostic value of OASIS score and SAPS II score.

RESULTS: A total of 11 098 adult ICU sepsis patients were enrolled in the final analysis, of which 2 320 died and 8 778 survived in hospital, with a mortality of 20.90%. Compared with the survivors, the non-survivors were older [years old: 71 (60, 81) vs. 67 (56, 78)], had longer length of ICU stay [days: 6.95 (3.39, 13.07) vs. 4.23 (2.19, 9.73)] and higher proportions of using vasopressor drugs, sedative drugs, mechanical ventilation and renal replacement therapy [vasopressor drugs: 50.65% (1 175/2 320) vs. 33.05% (2 901/8 778), sedative drugs: 58.53% (1 358/2 320) vs. 48.41% (4 249/8 778), mechanical ventilation: 89.57% (2 078/2 320) vs. 81.66% (7 168/8 778), renal replacement therapy: 11.98% (278/2 320) vs. 6.57% (577/8 778), all P < 0.01]. Moreover, the non-survivors had higher OASIS score [43 (36, 49) vs. 35 (29, 41), P < 0.01] and SAPS II score [49 (40, 60) vs. 38 (31, 47), P < 0.01] as compared with the survivors. ROC curve analysis showed that the AUC of OASIS score and SAPS II score for predicting in-hospital death of ICU patients with sepsis was 0.713 [95% confidence interval (95%CI) was 0.701-0.725] and 0.716 (95%CI was 0.704-0.728), respectively, and the Delong test showed no significant difference in AUC between the two scoring systems (P > 0.05).

CONCLUSIONS: OASIS score has a good predictive value for in-hospital mortality in sepsis patients, which is similar to SAPS II score. OASIS score is simpler and has a broader clinical application prospect than SAPS II score.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Luo C, Gu H, Jin Y, et al. [Comparison of the predictive value of the Oxford acute severity of illness score and simplified acute physiology score II for in-hospital mortality in intensive care unit patients with sepsis: an analysis based on MIMIC-IV database]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2022. PMID: 35692197. doi:10.3760/cma.j.cn121430-20210722-01080

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。