文献速递呼吸衰竭与机械通气复苏、休克与脓毒症

院前手动通气中呼吸力学的初步评估

A pilot evaluation of respiratory mechanics during prehospital manual ventilation.
PubMed 文献 · Resuscitation · 2022-06-08
一句话结论院前气管插管后手动通气潮气量总体在肺保护范围内(75%),但活动性心肺复苏时每预测体重潮气量更低、峰压更高。

这项前瞻性初步研究在院前高级气道置入患者中,由急救人员使用装置测量呼吸力学,共纳入54例患者、7371次插管后呼吸,评估每预测体重潮气量(VTPBW)在4-10 mL/kg肺保护范围内的比例,并按通气袋容积(大袋与小袋)和心脏骤停状态(活动性CPR、ROSC后、非骤停)分层。总体平均潮气量435 mL(95%CI 403, 467),VTPBW为7.0 mL/kg(95%CI 6.4, 7.6),75%的呼吸在肺保护范围内。平均VTPBW和峰压因骤停状态而异(活动性CPR较ROSC后绝对差为-0.36 mL/kg和32 cmH2O),但未因通气袋大小而异。作者认为院前测量呼吸力学可行,未来可研究呼吸力学与结局的关系。

要点

  • 院前气管插管后手动通气总体平均潮气量435 mL(95%CI 403, 467),VTPBW为7.0 mL/kg(95%CI 6.4, 7.6),75%的呼吸在4-10 mL/kg肺保护范围内。
  • 活动性CPR患者较ROSC后患者VTPBW绝对差为-0.36 mL/kg,峰压绝对差为32 cmH2O。
  • VTPBW和峰压未因通气袋容积(大袋与小袋)而异。
  • 54例患者中32例为心脏骤停、22例为其他情况;19例使用小袋、35例使用大袋。
  • 作者认为院前测量呼吸力学可行,未来可研究呼吸力学与结局的关系。

适用人群与场景

  • 院前接受高级气道置入的患者,共54例,其中32例心脏骤停、22例其他情况。

诊断标准与关键阈值

  • 肺保护范围定义为每预测体重潮气量(VTPBW)4-10 mL/kg。

研究设计与关键结果

  • 前瞻性初步研究,16个月内纳入54例院前高级气道置入患者,共测量7371次插管后呼吸。
  • 总体平均潮气量435 mL(95%CI 403, 467),VTPBW为7.0 mL/kg(95%CI 6.4, 7.6),75%的呼吸在4-10 mL/kg肺保护范围内。
  • 19例使用小袋、35例使用大袋;VTPBW和峰压未因通气袋大小而异。
  • 平均VTPBW和峰压因骤停状态而异:活动性CPR较ROSC后VTPBW绝对差-0.36 mL/kg,峰压绝对差32 cmH2O。

证据类型、等级与局限

  • 证据类型:前瞻性初步研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为院前测量呼吸力学可行;未来工作可研究呼吸力学与结局的关系,可能识别改善临床结局的机会。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

INTRODUCTION: Respiratory mechanics, such as tidal volume (VT) and inspiratory pressures, may affect outcome in hospitalized patients with respiratory failure. Little is known about respiratory mechanics in the prehospital setting.

METHODS: In this prospective, pilot investigation of patients receiving prehospital advanced airway placement, paramedics applied a device to measure respiratory mechanics. We evaluated tidal volume (VT) per predicted body weight (VTPBW) to determine the proportion of breaths within the lung-protective range of 4-10 mL/kg per PBW overall, according to ventilation bag volume (large versus small) and cardiac arrest status (active CPR, post-ROSC, non-arrest).

RESULTS: Over 16-months, 7371 post-intubation breaths were measured in 54 patients, 32 patients with cardiac arrest and 22 with other conditions. Paramedics ventilated 19 patients with a small bag and 35 patients with a large bag. Overall, mean VT was 435 mL (95% CI 403, 467); VTPBW was 7.0 mL/kg (95% CI 6.4, 7.6) with 75% within the lung-protective range. Mean VTPBW and peak pressure differed according to arrest status (absolute difference -0.36 mL/kg and 32 cmH2O for active CPR compared to post-ROSC), though not according to bag size.

CONCLUSIONS: We observed that measuring respiratory mechanics in the prehospital setting was feasible. Tidal volumes were generally delivered within a safe range. Respiratory mechanics varied most significantly with active CPR with lower VTPBW and higher peak pressures, though did not seem to be affected by bag size. Future work might examine the relationship between respiratory mechanics and outcomes, which may identify opportunities to improve clinical outcomes.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Yang BY, Blackwood JE, Shin J, et al. A pilot evaluation of respiratory mechanics during prehospital manual ventilation. Resuscitation. 2022. PMID: 35690127. doi:10.1016/j.resuscitation.2022.06.003

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。