文献速递复苏、休克与脓毒症创伤与烧伤

猪失血性休克模型中部分复苏性主动脉腔内球囊阻断时主动脉血流与压力的生理关系

The physiology of aortic flow and pressures during partial resuscitative endovascular balloon occlusion of the aorta in a swine model of hemorrhagic shock.
PubMed 文献 · J Trauma Acute Care Surg · 2022-05-12
一句话结论猪失血性休克模型显示,部分REBOA时远端平均动脉压与主动脉血流呈线性关系(R²=0.80),而近端平均动脉压与血流无明显关系(R²=0.29),提示pREBOA技术应依据远端而非近端平均动脉压调控远端主动脉血流。

本研究为猪失血性休克的回顾性数据分析,旨在探讨部分复苏性主动脉腔内球囊阻断(pREBOA)时远端与近端平均动脉压(MAP)及球囊远端主动脉血流之间的关系。队列1经历20%控制性失血后随机分为主动脉血流400 mL/min或完全阻断20分钟(n=11);队列2经历30%控制性失血后完全阻断主动脉30分钟(n=29);随后均以相似方式逐步撤除REBOA。结果显示远端MAP与主动脉血流呈线性关系(R²=0.80),近端MAP与血流无明显关系(R²=0.29);远端MAP重复测量相关系数为0.94(95%CI 0.94-0.94),大于近端MAP的-0.73(95%CI -0.74至-0.72)。作者认为pREBOA技术应依赖远端而非近端MAP来控制远端主动脉血流。

要点

  • 猪失血性休克模型撤除REBOA球囊期间,远端MAP与主动脉血流呈线性关系(R²=0.80)。
  • 近端MAP与主动脉血流无明显关系(R²=0.29)。
  • 远端MAP重复测量相关系数0.94(95%CI 0.94-0.94),大于近端MAP的-0.73(95%CI -0.74至-0.72)。
  • 作者认为pREBOA技术应依赖远端而非近端MAP来控制远端主动脉血流。

适用人群与场景

  • 猪失血性休克模型:队列1经历20%控制性失血后随机分为主动脉血流400 mL/min或完全阻断20分钟(n=11);队列2经历30%控制性失血后完全阻断主动脉30分钟(n=29)。
  • 研究关注REBOA球囊逐步撤除(wean)时间段为感兴趣时间点。

研究设计与关键结果

  • 研究类型:猪失血性休克模型的回顾性数据分析。
  • 队列1:20%控制性失血后随机分为主动脉血流400 mL/min或完全阻断20分钟(n=11)。
  • 队列2:30%控制性失血后完全阻断主动脉30分钟(n=29)。
  • 所有动物随后以相似方式逐步撤除REBOA;血压从REBOA球囊上方(近端)和下方(远端)采集;主动脉血流用手术植入的腹腔干上方主动脉血管周围流量探头测量。
  • 远端MAP与主动脉血流呈线性关系(R²=0.80);近端MAP与主动脉血流无明显关系(R²=0.29)。
  • 远端MAP重复测量相关系数0.94(95%CI 0.94-0.94),大于近端MAP的-0.73(95%CI -0.74至-0.72)。

证据类型、等级与局限

  • 证据类型:动物实验(猪失血性休克模型)的回顾性数据分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,pREBOA技术应依赖远端而非近端MAP来控制远端主动脉血流。
  • 作者指出,MAP与血流的关系将成为下一代pREBOA控制输入的组成部分。
  • 作者指出,这些数据可为未来在转化和临床背景下基于远端MAP探讨最佳流速和参数的研究提供信息。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Partial resuscitative endovascular balloon occlusion of the aorta (REBOA) has shown promise as a method to extend REBOA, but there lacks a standard definition of the technique. The purpose of this study was to investigate the relationships between distal and proximal mean arterial pressure (MAP) and distal aortic flow past a REBOA catheter. We hypothesize that a relationship between distal aortic flow and distal MAP in Zone 1 partial REBOA (pREBOA) is conserved and that there is no apparent relationship between aortic flow and proximal MAP.

METHODS: A retrospective data analysis of swine was performed. Cohort 1 underwent 20% controlled hemorrhage and then randomized to aortic flow of 400 mL/min or complete occlusion for 20 minutes (n = 11). Cohort 2 underwent 30% controlled hemorrhage followed by complete aortic occlusion for 30 minutes (n = 29). Then, they all underwent REBOA wean in a similar stepwise fashion. Blood pressure was collected from above (proximal) and below (distal) the REBOA balloon. Aortic flow was measured using a surgically implanted supraceliac aortic perivascular flow probe. The time period of balloon wean was taken as the time point of interest.

RESULTS: A linear relationship between distal MAP and aortic flow was observed ( R2 value, 0.80), while no apparent relationship appeared between proximal MAP and aortic flow ( R2 value, 0.29). The repeated-measures correlation coefficient for distal MAP (0.94; 95% confidence interval, 0.94-0.94) was greater than proximal MAP (-0.73; 95% confidence interval, -0.74 to -0.72).

CONCLUSION: The relationship between MAP and flow will be a component of next-generation pREBOA control inputs. This study provides evidence that pREBOA techniques should rely on distal rather than proximal MAP for control of distal aortic flow. These data could inform future inquiry into optimal flow rates and parameters based on distal MAP in both translational and clinical contexts.

来源:J Trauma Acute Care Surg,查看原文。版权归原作者所有。

参考来源

  1. Marble J, Patel NTP, Lane MR, et al. The physiology of aortic flow and pressures during partial resuscitative endovascular balloon occlusion of the aorta in a swine model of hemorrhagic shock. J Trauma Acute Care Surg. 2022. PMID: 35545802. doi:10.1097/TA.0000000000003667