文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

BioFire® FilmArray®肺炎检测panel与培养在哥伦比亚八家医院ICU收治的COVID-19肺炎患者中的诊断一致性:第三波疫情经验

Diagnostic concordance between BioFire® FilmArray® Pneumonia Panel and culture in patients with COVID-19 pneumonia admitted to intensive care units: the experience of the third wave in eight hospitals in Colombia.
PubMed 文献 · Crit Care · 2022-05-09
一句话结论在COVID-19机械通气患者中,FA-PNEU与培养总体一致性90.1%,阴性预测值99.1%–100%,但部分菌种阳性预测值低至50%。

这项前瞻性研究纳入哥伦比亚麦德林8家ICU中住院≤48小时、机械通气≤24小时的SARS-CoV-2患者,比较FA-PNEU与常规培养对细菌合并感染的检出及一致性。110例同时接受两种检测的样本中,FA-PNEU阳性24.54%、培养阳性17.27%,总体一致性90.1%,按菌种分层92.7%–100%。阳性预测值50%–100%,阴沟肠杆菌和金黄色葡萄球菌较低;阴性预测值99.1%–100%,MecA/C/MREJ特异度94.55%、阴性预测值100%。炎症指标在两种方法阳性与阴性患者间无显著差异,55.45%患者接受了至少一剂经验性抗生素。

要点

  • 110例同时接受FA-PNEU与培养的样本中,FA-PNEU阳性24.54% vs 培养阳性17.27%,总体一致性90.1%。
  • 按菌种分层一致性92.7%–100%;阴性预测值99.1%–100%,MecA/C/MREJ特异度94.55%、阴性预测值100%。
  • 阳性预测值50%–100%,阴沟肠杆菌和金黄色葡萄球菌的阳性预测值较低。
  • FA-PNEU检出最多的两种细菌为金黄色葡萄球菌(37.5%)和无乳链球菌(20%);培养为金黄色葡萄球菌(34.78%)和肺炎克雷伯菌(26.08%)。
  • 白细胞、C反应蛋白和降钙素原在两种方法阳性与阴性患者间无显著差异;61例(55.45%)接受了至少一剂经验性抗生素。

适用人群与场景

  • 哥伦比亚麦德林8家ICU中住院不超过48小时、机械通气不超过24小时的SARS-CoV-2患者。
  • 样本类型为微型支气管肺泡灌洗液或气管内吸引物。

诊断标准与关键阈值

  • 合并感染定义为通过FA-PNEU或培养鉴定出呼吸道病原体。
  • 在插管第一天采集血清检测白细胞、C反应蛋白和降钙素原。

处置流程与药物剂量

  • 分析经验性抗生素使用及根据FA-PNEU和培养结果调整抗生素管理的情况。

研究设计与关键结果

  • 前瞻性研究,纳入110例同时接受FA-PNEU和培养的样本,来自8家ICU。
  • FA-PNEU阳性24.54% vs 培养阳性17.27%;18例两者均阳性,82例均阴性,1例培养阳性而FA-PNEU阴性,9例FA-PNEU阳性而培养阴性。
  • FA-PNEU检出最多的细菌为金黄色葡萄球菌(37.5%)和无乳链球菌(20%);培养检出最多的为金黄色葡萄球菌(34.78%)和肺炎克雷伯菌(26.08%)。
  • 总体一致性90.1%,按微生物分层一致性92.7%–100%。
  • 阳性预测值50%–100%,阴沟肠杆菌和金黄色葡萄球菌较低;阴性预测值99.1%–100%;MecA/C/MREJ特异度94.55%、阴性预测值100%。
  • 炎症反应指标在两种方法阳性与阴性患者间无显著差异;61例(55.45%)接受了至少一剂经验性抗生素。

证据类型、等级与局限

  • 证据类型:前瞻性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在COVID-19机械通气患者中,FA-PNEU的阴性预测值高(99.1%–100%),可能有助于排除细菌合并感染。
  • FA-PNEU对阴沟肠杆菌和金黄色葡萄球菌的阳性预测值较低(50%–100%范围内),阳性结果需结合培养确认。
  • 原文未据此给出推荐。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The detection of coinfections is important to initiate appropriate antimicrobial therapy. Molecular diagnostic testing identifies pathogens at a greater rate than conventional microbiology. We assessed both bacterial coinfections identified via culture or the BioFire® FilmArray® Pneumonia Panel (FA-PNEU) in patients infected with SARS-CoV-2 in the ICU and the concordance between these techniques.

METHODS: This was a prospective study of patients with SARS-CoV-2 who were hospitalized for no more than 48 h and on mechanical ventilation for no longer than 24 h in 8 ICUs in Medellín, Colombia. We studied mini-bronchoalveolar lavage or endotracheal aspirate samples processed via conventional culture and the FA-PNEU. Coinfection was defined as the identification of a respiratory pathogen using the FA-PNEU or cultures. Serum samples of leukocytes, C-reactive protein, and procalcitonin were taken on the first day of intubation. We analyzed the empirical antibiotics and the changes in antibiotic management according to the results of the FA-PNEUM and cultures.

RESULTS: Of 110 patients whose samples underwent both methods, FA-PNEU- and culture-positive samples comprised 24.54% versus 17.27%, respectively. Eighteen samples were positive in both techniques, 82 were negative, 1 was culture-positive with a negative FA-PNEU result, and 9 were FA-PNEU-positive with negative culture. The two bacteria most frequently detected by the FA-PNEU were Staphylococcus aureus (37.5%) and Streptococcus agalactiae (20%), and those detected by culture were Staphylococcus aureus (34.78%) and Klebsiella pneumoniae (26.08%). The overall concordance was 90.1%, and when stratified by microorganism, it was between 92.7 and 100%. The positive predictive value (PPV) was between 50 and 100% and were lower for Enterobacter cloacae and Staphylococcus aureus. The negative predictive value (NPV) was high (between 99.1 and 100%); MecA/C/MREJ had a specificity of 94.55% and an NPV of 100%. The inflammatory response tests showed no significant differences between patients whose samples were positive and negative for both techniques. Sixty-one patients (55.45%) received at least one dose of empirical antibiotics.

CONCLUSIONS: The overall concordance was 90.1%, and it was between 92.7% and 100% when stratified by microorganisms. The positive predictive value was between 50 and 100%, with a very high NPV.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Molina FJ, Botero LE, Isaza JP, et al. Diagnostic concordance between BioFire® FilmArray® Pneumonia Panel and culture in patients with COVID-19 pneumonia admitted to intensive care units: the experience of the third wave in eight hospitals in Colombia. Crit Care. 2022. PMID: 35534867. doi:10.1186/s13054-022-04006-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。