文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

呼气末与动脉二氧化碳分压比值指导静脉-静脉体外膜氧合撤机

End-Tidal to Arterial Pco2 Ratio as Guide to Weaning from Venovenous Extracorporeal Membrane Oxygenation.
PubMed 文献 · Am J Respir Crit Care Med · 2022-01-01
一句话结论在VV-ECMO撤机中,撤机失败主要源于消除CO2的呼吸做功高,较高的PetCO2/PaCO2比值与更大的撤机成功可能性相关。

这项多中心研究纳入接受VV-ECMO的严重急性呼吸窘迫综合征机械通气成人,包括生理学队列(n=26)的前瞻性干预研究和临床队列(n=638)的回顾性研究,探讨基于CO2消除的变量预测VV-ECMO撤机准备情况。临床队列和生理学队列的撤机失败率分别为37%和42%,生理学队列失败的主要原因是吸气努力高或呼吸频率快。撤机失败患者消除单位容积CO2的做功是对照的两倍(68.9 [42.4-123] vs. 39 [20.1-57] cm H2O/[L/min];P = 0.007),生理死腔更高(68 [58.73] % vs. 54 [41.64] %;P = 0.012)。基线PetCO2/PaCO2比值与撤机结局强相关,受试者工作特征曲线下面积为0.87(95% CI 0.71-1);临床队列中撤机试验前(比值比4.14;95% CI 1.32-12.2;P = 0.015)和扫气流量为零时(比值比13.1;95% CI 4-44.4;P < 0.001)该比值均与撤机结局相关。

要点

  • 在生理学队列中,撤机失败的主要原因是吸气努力高或呼吸频率快,而非氧合问题。
  • 撤机失败患者消除单位容积CO2的做功显著更高:68.9 [42.4-123] vs. 39 [20.1-57] cm H2O/[L/min];P = 0.007。
  • 撤机失败患者生理死腔显著更高:68 [58.73] % vs. 54 [41.64] %;P = 0.012。
  • 基线PetCO2/PaCO2比值预测撤机结局的AUC为0.87(95% CI 0.71-1)。
  • 临床队列中,撤机试验前PetCO2/PaCO2比值与撤机结局相关(OR 4.14;95% CI 1.32-12.2;P = 0.015),扫气流量为零时相关更强(OR 13.1;95% CI 4-44.4;P < 0.001)。

适用人群与场景

  • 接受VV-ECMO的严重急性呼吸窘迫综合征机械通气成人(多中心研究)。

研究设计与关键结果

  • 研究类型:多中心研究,包括生理学队列的前瞻性干预研究(n=26)和临床队列的回顾性研究(n=638);人群为接受VV-ECMO的严重急性呼吸窘迫综合征机械通气成人。
  • 临床队列和生理学队列的撤机失败率分别为37%和42%;生理学队列失败的主要原因是吸气努力高或呼吸频率快。
  • 所有患者呼出CO2量相似,但撤机试验失败患者PETCO2更高以维持PaCO2不变。
  • 撤机失败患者消除单位容积CO2的做功为68.9 [42.4-123] vs. 39 [20.1-57] cm H2O/[L/min];P = 0.007。
  • 撤机失败患者生理死腔为68 [58.73] % vs. 54 [41.64] %;P = 0.012。
  • 基线PetCO2/PaCO2比值与撤机结局强相关,AUC为0.87(95% CI 0.71-1)。
  • 临床队列中,撤机试验前PetCO2/PaCO2比值与撤机结局相关(OR 4.14;95% CI 1.32-12.2;P = 0.015);扫气流量为零时OR为13.1(95% CI 4-44.4;P < 0.001)。

证据类型、等级与局限

  • 证据类型:多中心研究,含前瞻性干预生理学队列和回顾性临床队列。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为VV-ECMO撤机失败的主要原因是消除CO2的做功高,较高的PetCO2/PaCO2比值与更大的撤机成功可能性相关。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rationale: Weaning from venovenous extracorporeal membrane oxygenation (VV-ECMO) is based on oxygenation and not on carbon dioxide elimination. Objectives: To predict readiness to wean from VV-ECMO. Methods: In this multicenter study of mechanically ventilated adults with severe acute respiratory distress syndrome receiving VV-ECMO, we investigated a variable based on CO2 elimination. The study included a prospective interventional study of a physiological cohort (n = 26) and a retrospective clinical cohort (n = 638). Measurements and Main Results: Weaning failure in the clinical and physiological cohorts were 37% and 42%, respectively. The main cause of failure in the physiological cohort was high inspiratory effort or respiratory rate. All patients exhaled similar amounts of CO2, but in patients who failed the weaning trial, [Formula: see text]e was higher to maintain the PaCO2 unchanged. The effort to eliminate one unit-volume of CO2, was double in patients who failed (68.9 [42.4-123] vs. 39 [20.1-57] cm H2O/[L/min]; P = 0.007), owing to the higher physiological Vd (68 [58.73] % vs. 54 [41.64] %; P = 0.012). End-tidal partial carbon dioxide pressure (PetCO2)/PaCO2 ratio was a clinical variable strongly associated with weaning outcome at baseline, with area under the receiver operating characteristic curve of 0.87 (95% confidence interval [CI], 0.71-1). Similarly, the PetCO2/PaCO2 ratio was associated with weaning outcome in the clinical cohort both before the weaning trial (odds ratio, 4.14; 95% CI, 1.32-12.2; P = 0.015) and at a sweep gas flow of zero (odds ratio, 13.1; 95% CI, 4-44.4; P < 0.001). Conclusions: The primary reason for weaning failure from VV-ECMO is high effort to eliminate CO2. A higher PetCO2/PaCO2 ratio was associated with greater likelihood of weaning from VV-ECMO.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Lazzari S, Romitti F, Busana M, et al. End-Tidal to Arterial Pco2 Ratio as Guide to Weaning from Venovenous Extracorporeal Membrane Oxygenation. Am J Respir Crit Care Med. 2022. PMID: 35608503. doi:10.1164/rccm.202201-0135OC

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。