斑点追踪超声心动图在机械通气与机械循环支持中的应用探索
本文为叙述性综述,检索PubMed与Excerpta Medica Database(2012—2021年)并手工扫描参考文献,纳入相关文献进行叙述性综合。斑点追踪超声心动图(STE)是已确立的心肌功能后处理分析方法,已纳入心肌与瓣膜病变诊断和预后评估的指南推荐,但在重症监护环境中的潜力尚未充分实现。在有限的研究中,机械通气(MV)与机械循环支持(MCS)参数变化时,STE始终是比传统2D和Doppler参数更敏感的心肌功能变化标志物。作者结论:尽管当前证据极为有限,STE应变被提示为比常规超声参数更敏感、可重复性更好的心肌功能参数,可能在重症监护环境下MV和MCS患者的评估中有价值,需更大规模人群的进一步研究阐明其预后能力及作为床旁工具指导临床实践的价值。
要点
- STE是已确立的心肌功能后处理分析方法,已纳入心肌与瓣膜病变诊断和预后评估的指南推荐。
- 在有限的研究中,MV与MCS参数变化时,STE始终是比传统2D和Doppler参数更敏感的心肌功能变化标志物。
- 作者结论:尽管当前证据极为有限,STE应变被提示为比常规超声参数更敏感、可重复性更好的心肌功能参数。
- STE在重症监护环境中的潜力尚未充分实现,其在MV和MCS患者中的效用可观,可能用于评估心肌功能的细微变化。
- 需更大规模人群的进一步研究阐明STE的预后能力及其作为床旁工具指导MV和MCS患者临床实践的价值。
适用人群与场景
- 接受机械通气(MV)的患者
- 接受机械循环支持(MCS)的患者,检索词包括体外膜氧合(ECMO)、心室辅助装置(VAD)和左心室卸载装置
研究设计与关键结果
- 研究类型:叙述性综述;检索PubMed与Excerpta Medica Database(2012—2021年),并手工扫描所有入选研究的参考文献列表以进一步识别可能相关的研究。
- 检索词:Speckle-Tracking Echocardiography、Mechanical Ventilation、Mechanical Circulatory Support、Extracorporeal Membrane Oxygenation、Ventricular Assist Devices、Left Ventricular Unloading Devices。
- 在有限的研究中,MV与MCS参数变化时,STE始终是比传统2D和Doppler参数更敏感的心肌功能变化标志物。
- STE已纳入心肌与瓣膜病变诊断和预后评估的指南推荐,但其在重症监护环境中的潜力尚未充分实现。
证据类型、等级与局限
- 证据类型:叙述性综述。
- 作者指出当前证据极为有限,需更大规模人群的进一步研究阐明STE的预后能力及其作为床旁工具指导MV和MCS患者临床实践的价值。
对床旁实践的改变
- 作者认为,尽管当前证据极为有限,STE应变是比常规超声参数更敏感、可重复性更好的心肌功能参数,可能在重症监护环境下MV和MCS患者的评估中有价值。
- 作者指出,需更大规模人群的进一步研究阐明STE的预后能力及其作为床旁工具指导MV和MCS患者临床实践的价值。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
UNLABELLED: This narrative review aims to discuss the potential applicability of speckle-tracking echocardiography (STE) in patients under mechanical ventilation (MV) and mechanical circulatory support (MCS). Both its benefits and limitations were considered through critical analyses of the current available evidence.
DATA SOURCES AND STUDY SELECTION: A literature search was conducted in PubMed and Excerpta Medica Database indexed databases (2012-2021). In addition, the reference lists of all selected studies were manually scanned for further identification of potentially relevant studies.
DATA EXTRACTION: The terms "Speckle-Tracking Echocardiography," "Mechanical Ventilation," "Mechanical Circulatory Support," "Extracorporeal Membrane Oxygenation," "Ventricular Assist Devices," and "Left Ventricular Unloading Devices" were searched for the identification of relevant articles for narrative synthesis.
DATA SYNTHESIS: STE is a well-established post-processing method of analyzing myocardial function, with potentially greater clinical utility than conventional 2D echocardiography. STE has been incorporated into the guideline recommendations for both the diagnostic and prognostic evaluations of myocardial and valvular pathologies. However, the potential of STE application within critical care settings has not yet been fully realized. Its utility in the assessment of patients undergoing MV and MCS is substantial. Specifically, it may serve as an ideal modality in the assessment of subtle changes in cardiac function. In the limited number of studies reviewed, STE was consistently a more sensitive marker of myocardial functional change, compared with traditional markers of 2D and Doppler parameters during changes in MV and MCS.
CONCLUSIONS: Although current evidence is extremely limited, STE strain is suggested to be a more sensitive and reproducible parameter of myocardial function than conventional echocardiographic parameters and may have value in the assessment of patients undergoing MV and MCS in critical care settings. Further studies in larger populations are required to elucidate STE's prognostic capability and its value as a point-of-care tool in guiding clinical practice for subjects under MV and MCS.
参考来源
- Sato K, Chan J, Appadurai V, et al. Exploration of the Utility of Speckle-Tracking Echocardiography During Mechanical Ventilation and Mechanical Circulatory Support. Crit Care Explor. 2022. PMID: 35372843. doi:10.1097/CCE.0000000000000666
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。