呼气末二氧化碳分压评估被动抬腿试验预测脓毒性休克患者容量反应性的价值
该研究纳入2019年12月至2021年6月新疆维吾尔自治区人民医院重症医学二科收治的43例脓毒性休克患者,监测被动抬腿试验(PLR)及容量负荷试验(VE)前后PETCO2、心指数(CI)、每搏量变异度(SVV)、平均动脉压(MAP)等血流动力学指标。以VE后ΔCI≥15%为反应组(22例,51.2%),<15%为非反应组(21例,48.8%)。反应组PLR后MAP、SVV、CI及PETCO2变化值均高于非反应组(均P<0.05)。PLR前后ΔPETCO2评估容量反应性的ROC曲线下面积(AUC)为0.881,界值5.9%时敏感度76.7%、特异度89.5%、正确指数0.68;SVV基线AUC为0.835,界值12.8%时敏感度84.6%、特异度80.0%、正确指数0.65。作者认为PLR后PETCO2变化可作为无创、简便、安全、可靠的预测脓毒性休克患者容量反应性的指标。
要点
- 脓毒性休克患者PLR后ΔPETCO2评估容量反应性AUC 0.881,界值5.9%时敏感度76.7%、特异度89.5%、正确指数0.68。
- PLR后ΔPETCO2预测价值不低于SVV基线(AUC 0.835,界值12.8%时敏感度84.6%、特异度80.0%、正确指数0.65)。
- 反应组PLR后ΔPETCO2为3.4±1.8 mmHg,高于非反应组的1.1±1.0 mmHg(P<0.05)。
- 反应组VE后ΔPETCO2为3.3±1.2 mmHg,高于非反应组的1.3±1.1 mmHg(P<0.05)。
- 作者认为PLR后PETCO2变化可作为无创、简便、安全、可靠的容量反应性预测指标。
适用人群与场景
- 2019年12月至2021年6月新疆维吾尔自治区人民医院重症医学二科收治的脓毒性休克患者43例。
诊断标准与关键阈值
- 以容量负荷试验后CI变化率(ΔCI)分组:ΔCI≥15%为反应组,ΔCI<15%为非反应组。
- ΔPETCO2 PLR评估容量反应性的临界值为5.9%,敏感度76.7%,特异度89.5%,正确指数0.68。
- SVV基线评估容量反应性的截断值为12.8%,敏感度84.6%,特异度80.0%,正确指数0.65。
研究设计与关键结果
- 研究类型为单中心研究,纳入43例脓毒性休克患者,反应组22例(51.2%),非反应组21例(48.8%)。
- PLR后变化值反应组 vs 非反应组:MAP 3.8±2.1 mmHg vs 1.4±2.0 mmHg,SVV -5.3±2.5% vs 2.7±2.0%,CI 0.48±0.13 mL×s⁻¹×m⁻² vs 0.14±0.18 mL×s⁻¹×m⁻²,PETCO2 3.4±1.8 mmHg vs 1.1±1.0 mmHg,均P<0.05(1 mmHg≈0.133 kPa)。
- VE后变化值反应组 vs 非反应组:HR -8.3±2.8 次/min vs -2.3±3.7 次/min,MAP 3.8±2.4 mmHg vs 1.2±1.7 mmHg,SVV -6.3±3.1% vs -3.3±2.0%,CI 0.51±0.14 mL×s⁻¹×m⁻² vs 0.16±0.12 mL×s⁻¹×m⁻²,PETCO2 3.3±1.2 mmHg vs 1.3±1.1 mmHg,均P<0.05。
- PLR前后ΔPETCO2评估容量反应性的AUC为0.881,临界值5.9%时敏感度76.7%、特异度89.5%、正确指数0.68;SVV基线AUC为0.835,截断值12.8%时敏感度84.6%、特异度80.0%、正确指数0.65。
- ΔPETCO2的预测价值不低于SVV基线。
证据类型、等级与局限
- 证据类型:单中心研究(样本量43例)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为PLR试验后PETCO2变化可作为无创、简便、安全、可靠的指标,用于预测脓毒性休克患者的容量反应性。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the value of partial pressure of end-tidal carbon dioxide (PETCO2) combined with passive leg raising test (PLR) in predicting volume responsiveness in patients with septic shock.
METHODS: A total of 43 patients with septic shock admitted to the second department of critical care medicine, People's Hospital of Xinjiang Uygur Autonomous Region from December 2019 to June 2021 were selected as the research subjects. PETCO2, cardiac index (CI), stroke volume variation (SVV), mean arterial pressure (MAP) and other hemodynamic indexes were monitored before and after PLR and volume stress test (VE). Subjects were grouped according to the CI variation rate (ΔCI) after VE test. Patients with ΔCI ≥ 15% were the responding group, and patients with ΔCI < 15% were the non-responding group. The receiver operator characteristic curve (ROC curve) was drawn to analyze the evaluation value of the change in PETCO2 after PLR on the evaluation value of fluid responsiveness.
RESULTS: Among the 43 patients, 22 cases were in the responding group, accounting for 51.2%; 21 cases were in the non-responding group, accounting for 48.8%. After the PLR test, the change values of MAP, SVV, CI and PETCO2 in the responding group were higher than those in the non-responding group, and the differences were statistically significant [MAP (mmHg): 3.8±2.1 vs. 1.4±2.0, SVV (%): -5.3±2.5 vs. 2.7±2.0, CI (mL×s-1×m-2): 0.48±0.13 vs. 0.14±0.18, PETCO2 (mmHg): 3.4±1.8 vs. 1.1±1.0, all P < 0.05, 1 mmHg ≈ 0.133 kPa]. After the VE test, the changes of HR, MAP, SVV, CI and PETCO2 in the responding group were higher than those in the non-responding group [HR (times/min): -8.3±2.8 vs. -2.3±3.7, MAP (mmHg): 3.8±2.4 vs. 1.2±1.7, SVV (%): -6.3±3.1 vs. -3.3±2.0, CI (mL×s-1×m-2): 0.51±0.14 vs. 0.16±0.12, PETCO2 (mmHg): 3.3±1.2 vs. 1.3±1.1, all P < 0.05]. The area under the ROC curve (AUC) of the change in PETCO2 before and after the PLR test (ΔPETCO2 PLR) for evaluating fluid responsiveness was 0.881. When the critical value was 5.9%, the sensitivity was 76.7%, the specificity was 89.5%, and the correct index was 0.68; the AUC for SVV baseline assessment of fluid responsiveness was 0.835, and when the cut-off value was 12.8%, the sensitivity was 84.6%, the specificity was 80.0%, and the correct index was 0.65. The predictive value of ΔPETCO2 was not lower than the SVV baseline.
CONCLUSIONS: After the PLR test, the change of PETCO2 can be used as a non-invasive, simple, safe and reliable indicator for predicting the volume responsiveness of patients with septic shock.
参考来源
- Liu Y, Tang W, Xiao D, et al. [End-tidal carbon dioxide partial pressure to assess the value of passive leg-raising test in predicting volume responsiveness in patients with septic shock]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2022. PMID: 35387717. doi:10.3760/cma.j.cn121430-20211130-01810
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。