脓毒症机械通气患者膈肌功能严重但可逆性受损
本研究为两项前瞻性观察研究的二次分析,纳入92例机械通气患者,插管24小时内及切换至压力支持模式时各测一次双侧前部磁刺激膈神经诱发的气管内压(Ptr,stim)。脓毒症患者51例(55%),其插管24小时内Ptr,stim低于非脓毒症患者(6.3 vs 9.8 cmH2O,p=0.004),两次测量间Ptr,stim变化为+19% vs -7%(p=0.005)。超声亚组中两组呼气末膈肌厚度均下降,膈肌功能下降或无变化者28天死亡率更高。
要点
- 脓毒症患者插管24小时内Ptr,stim为6.3(4.9-8.7)cmH2O,低于非脓毒症患者的9.8(7.0-14.2)cmH2O(p=0.004)。
- 两次测量间脓毒症患者Ptr,stim变化+19%(-13-61),非脓毒症患者-7%(-40-12),组间p=0.005。
- 脓毒症患者两次评估间机械通气中位时间为4(2-6)天,非脓毒症患者为3(2-4)天(p=0.073)。
- 超声亚组中脓毒症与非脓毒症患者呼气末膈肌厚度均下降。
- 膈肌功能下降或无变化的患者28天死亡率更高。
适用人群与场景
- 机械通气患者,纳入两项前瞻性观察研究,插管24小时内及切换至压力支持模式时各评估一次膈肌功能。
- 脓毒症患者51例(55%),插管时按Sepsis-3国际指南定义;非脓毒症患者41例。
- 脓毒症患者主要通气原因为肺炎相关急性呼吸衰竭(37/51;73%);非脓毒症患者主要为非肺炎相关急性呼吸衰竭(16/41;39%)、昏迷(13/41;32%)和心跳骤停(6/41;15%)。
诊断标准与关键阈值
- 脓毒症定义:插管时按Sepsis-3国际指南。
- 膈肌功能评估:双侧前部磁刺激膈神经诱发的气管内压(Ptr,stim),分别于插管24小时内和切换至压力支持模式时测量。
- 膈肌功能变化:压力支持模式下的Ptr,stim减去插管24小时内Ptr,stim。
研究设计与关键结果
- 研究类型:两项前瞻性观察研究的二次分析;样本量92例。
- 插管24小时内Ptr,stim:脓毒症患者6.3(4.9-8.7)cmH2O vs 非脓毒症患者9.8(7.0-14.2)cmH2O(p=0.004)。
- 两次评估间机械通气时间:脓毒症患者4(2-6)天 vs 非脓毒症患者3(2-4)天(p=0.073)。
- 两次测量间Ptr,stim变化:脓毒症患者+19%(-13-61) vs 非脓毒症患者-7%(-40-12)(p=0.005)。
- 超声亚组:脓毒症和非脓毒症患者呼气末膈肌厚度均下降。
- 28天死亡率:膈肌功能下降或无变化的患者更高。
证据类型、等级与局限
- 证据类型:两项前瞻性观察研究的二次分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,脓毒症患者膈肌功能受损更严重但可逆,膈肌功能增加与更好的生存相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Whether sepsis-associated diaphragm dysfunction may improve despite the exposure of mechanical ventilation in critically ill patients is unclear. This study aims at describing the diaphragm function time course of septic and non-septic mechanically ventilated patients.
METHODS: Secondary analysis of two prospective observational studies of mechanically ventilated patients in whom diaphragm function was assessed twice: within the 24 h after intubation and when patients were switched to pressure support mode, by measuring the endotracheal pressure in response to bilateral anterior magnetic phrenic nerve stimulation (Ptr,stim). Change in diaphragm function was expressed as the difference between Ptr,stim measured under pressure support mode and Ptr,stim measured within the 24 h after intubation. Sepsis was defined according to the Sepsis-3 international guidelines upon inclusion. In a sub-group of patients, the right hemidiaphragm thickness was measured by ultrasound.
RESULTS: Ninety-two patients were enrolled in the study. Sepsis upon intubation was present in 51 (55%) patients. In septic patients, primary reason for ventilation was acute respiratory failure related to pneumonia (37/51; 73%). In non-septic patients, main reasons for ventilation were acute respiratory failure not related to pneumonia (16/41; 39%), coma (13/41; 32%) and cardiac arrest (6/41; 15%). Ptr,stim within 24 h after intubation was lower in septic patients as compared to non-septic patients: 6.3 (4.9-8.7) cmH2O vs. 9.8 (7.0-14.2) cmH2O (p = 0.004), respectively. The median (interquartile) duration of mechanical ventilation between first and second diaphragm evaluation was 4 (2-6) days in septic patients and 3 (2-4) days in non-septic patients (p = 0.073). Between first and second measurements, the change in Ptr,stim was + 19% (- 13-61) in septic patients and - 7% (- 40-12) in non-septic patients (p = 0.005). In the sub-group of patients with ultrasound measurements, end-expiratory diaphragm thickness decreased in both, septic and non-septic patients. The 28-day mortality was higher in patients with decrease or no change in diaphragm function.
CONCLUSION: Septic patients were associated with a more severe but reversible impaired diaphragm function as compared to non-septic patients. Increase in diaphragm function was associated with a better survival.