脑震荡所致皮层扩散性去极化的数值模拟:优化直流脑电电极间距以实现无创视觉检测
通过有限元数值模型模拟脑表面SD引起的头皮电压变化,并与Drenckhahn等(Brain 135:853, 2012) retrospectively评估的动脉瘤性蛛网膜下腔出血患者数据比较。模拟的峰值头皮/皮层电压比Vscalp/Vcortex为0.0735,回顾数据为0.0316(0.0221, 0.0527)(中位数[第1四分位数,第3四分位数],n=161,p<0.001,单样本Wilcoxon符号秩检验);差异归因于脑震荡SD与动脉瘤性蛛网膜下腔出血SD形态不同及人体电压测量固有局限。利用模拟头皮表面电位设计虚拟头皮检测阵列,误差分析与视觉重建显示1 cm为视觉识别皮层SD传播性头皮电压的最佳电极间距,2 cm及以上产生失真图像和高重建误差。作者认为脑震荡(及其他)SD可从头皮检测,可能确认人脑震荡中SD发生、提供基于生理机制的脑震荡诊断,并推动严重急性脑损伤的无创SD检测。
要点
- 模拟的峰值头皮/皮层电压比Vscalp/Vcortex为0.0735,回顾性动脉瘤性蛛网膜下腔出血数据为0.0316(0.0221, 0.0527)(中位数[第1四分位数,第3四分位数],n=161,p<0.001,单样本Wilcoxon符号秩检验)。
- 虚拟头皮检测阵列的误差分析与视觉重建显示,1 cm为视觉识别皮层SD传播性头皮电压的最佳电极间距。
- 电极间距2 cm及以上会产生失真图像和高重建误差。
- 作者认为脑震荡(及其他)SD可从头皮检测,可能确认人脑震荡中SD发生并提供基于生理机制的脑震荡诊断。
适用人群与场景
- 脑震荡患者(原文基于机械性脑变形与脑震荡实验研究提出SD假设)
- 动脉瘤性蛛网膜下腔出血患者(用于回顾性数据比较,来自Drenckhahn等,Brain 135:853, 2012)
- 严重急性脑损伤(原文结论提及无创SD检测的应用场景)
研究设计与关键结果
- 研究类型:有限元数值模拟研究,并与回顾性评估的动脉瘤性蛛网膜下腔出血患者数据比较(Drenckhahn等,Brain 135:853, 2012)。
- 模拟的峰值头皮/皮层电压比Vscalp/Vcortex为0.0735。
- 回顾性评估数据的峰值头皮/皮层电压比为0.0316(0.0221, 0.0527)(中位数[第1四分位数,第3四分位数],n=161,p<0.001,单样本Wilcoxon符号秩检验)。
- 模拟值与回顾数据的差异归因于脑震荡SD与动脉瘤性蛛网膜下腔出血SD形态不同,以及人体研究电压测量的固有局限。
- 利用模拟头皮表面电位设计虚拟头皮检测阵列,误差分析与视觉重建显示1 cm为视觉识别皮层SD传播性头皮电压的最佳电极间距。
- 电极间距2 cm及以上产生失真图像和高重建误差。
证据类型、等级与局限
- 证据类型:有限元数值模拟研究,与回顾性人体数据比较。
- 局限:原文指出模拟值与回顾数据的差异可归因于脑震荡SD与动脉瘤性蛛网膜下腔出血SD形态不同,以及人体研究电压测量的固有局限。
对床旁实践的改变
- 作者认为脑震荡(及其他)SD可从头皮检测,可能确认人脑震荡中SD发生,提供基于生理机制的脑震荡诊断,并推动严重急性脑损伤的无创SD检测。
- 模拟分析提示1 cm为视觉识别皮层SD传播性头皮电压的最佳电极间距,2 cm及以上产生失真图像和高重建误差。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Cortical spreading depolarization (SD) is a propagating depolarization wave of neurons and glial cells in the cerebral gray matter. SD occurs in all forms of severe acute brain injury, as documented by using invasive detection methods. Based on many experimental studies of mechanical brain deformation and concussion, the occurrence of SDs in human concussion has often been hypothesized. However, this hypothesis cannot be confirmed in humans, as SDs can only be detected with invasive detection methods that would require either a craniotomy or a burr hole to be performed on athletes. Typical electroencephalography electrodes, placed on the scalp, can help detect the possible presence of SD but have not been able to accurately and reliably identify SDs.
METHODS: To explore the possibility of a noninvasive method to resolve this hurdle, we developed a finite element numerical model that simulates scalp voltage changes that are induced by a brain surface SD. We then compared our simulation results with retrospectively evaluated data in patients with aneurysmal subarachnoid hemorrhage from Drenckhahn et al. (Brain 135:853, 2012).
RESULTS: The ratio of peak scalp to simulated peak cortical voltage, Vscalp/Vcortex, was 0.0735, whereas the ratio from the retrospectively evaluated data was 0.0316 (0.0221, 0.0527) (median [1st quartile, 3rd quartile], n = 161, p < 0.001, one sample Wilcoxon signed-rank test). These differing values provide validation because their differences can be attributed to differences in shape between concussive SDs and aneurysmal subarachnoid hemorrhage SDs, as well as the inherent limitations in human study voltage measurements. This simulated scalp surface potential was used to design a virtual scalp detection array. Error analysis and visual reconstruction showed that 1 cm is the optimal electrode spacing to visually identify the propagating scalp voltage from a cortical SD. Electrode spacings of 2 cm and above produce distorted images and high errors in the reconstructed image.
CONCLUSIONS: Our analysis suggests that concussive (and other) SDs can be detected from the scalp, which could confirm SD occurrence in human concussion, provide concussion diagnosis on the basis of an underlying physiological mechanism, and lead to noninvasive SD detection in the setting of severe acute brain injury.
参考来源
- Hund SJ, Brown BR, Lemale CL, et al. Numerical Simulation of Concussive-Generated Cortical Spreading Depolarization to Optimize DC-EEG Electrode Spacing for Noninvasive Visual Detection. Neurocrit Care. 2022. PMID: 35233716. doi:10.1007/s12028-021-01430-x
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。