快速发展的城市自动体外除颤器配置优化策略探讨:以深圳宝安区为例
该回顾性观察研究纳入深圳市宝安区2019年3月1日至2020年2月29日心脏骤停数据库登记的525例院外心脏骤停(OHCA)事件,以OHCA发生地点与最近AED的最小距离≤100 m定义为AED覆盖,分析公共场所与非公共场所的AED覆盖情况。结果显示OHCA最高发于住宅区54.5%(286/525)和工业区14.3%(75/525);全区252台AED,即使全部24小时可取,覆盖率也仅21.9%(115/525),公共场所与非公共场所覆盖率分别为31.6%(37/117)和19.1%(78/408),分布不均。假设对OHCA例数超过2例的住宅社区和工业区各配置1台AED,非公共场所覆盖率由19.1%(78/408)升至28.2%(115/408)。作者认为快速发展的城市应在保证AED 24小时可用的前提下,优先覆盖住宅社区和工业区等非公共场所。
要点
- 深圳市宝安区525例OHCA中,住宅区占54.5%(286/525)、工业区占14.3%(75/525),为OHCA最高发区域。
- 全区252台AED,即使全部实现24小时可取,AED覆盖率也仅21.9%(115/525)。
- 公共场所AED覆盖率31.6%(37/117)高于非公共场所19.1%(78/408),非公共场所覆盖率低且分布不均。
- 假设对OHCA例数超过2例的住宅社区和工业区各配置1台AED,非公共场所覆盖率由19.1%(78/408)升至28.2%(115/408)。
- 假设公共场所AED全部24小时可取,全区覆盖率由16.8%(88/525)升至21.9%(115/525),公共场所由29.1%(34/117)升至31.6%(37/117),非公共场所由13.2%(54/408)升至19.1%(78/408)。
适用人群与场景
- 深圳市宝安区2019年3月1日至2020年2月29日心脏骤停数据库登记的院外心脏骤停(OHCA)事件,共525例。
诊断标准与关键阈值
- 以OHCA发生地点与最近AED的最小距离≤100 m定义为AED覆盖,最小距离>100 m定义为非AED覆盖。
处置流程与药物剂量
- 作者认为,深圳等快速发展城市的AED配置策略应为:在保证AED 24小时可用的前提下,优先覆盖住宅社区和工业区等非公共场所的AED数量;公共场所AED实现24小时可取。
研究设计与关键结果
- 回顾性观察研究纳入深圳市宝安区2019年3月1日至2020年2月29日登记的525例OHCA事件;OHCA最高发于住宅区54.5%(286/525)和工业区14.3%(75/525)。
- 宝安区共有252台AED,115例OHCA事件发生在AED覆盖区域内;即使全部AED实现24小时随时可取,覆盖率也仅21.9%(115/525)。
- 公共场所与非公共场所AED覆盖率分别为31.6%(37/117)和19.1%(78/408),分布不均,非公共场所覆盖率低。
- 假设对OHCA例数超过2例的住宅社区和工业区各配置1台AED,非公共场所AED覆盖率由19.1%(78/408)升至28.2%(115/408)。
- 假设公共场所全部AED实现24小时随时可取,全区AED覆盖率由16.8%(88/525)升至21.9%(115/525),公共场所由29.1%(34/117)升至31.6%(37/117),非公共场所由13.2%(54/408)升至19.1%(78/408)。
证据类型、等级与局限
- 证据类型:回顾性观察研究(基于宝安区心脏骤停数据库的真实世界数据)。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,快速发展城市的AED配置应在保证24小时可用的前提下,优先增加住宅社区和工业区等非公共场所的AED覆盖,而非仅增加公共场所AED数量。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the automated external defibrillator (AED) configuration optimization strategy in line with the characteristics of the rapidly developing cities by analyzing the actual coverage of AED in Bao'an District based on the real world data of out-of-hospital cardiac arrest (OHCA) in Bao'an District, Shenzhen City.
METHODS: The data of cardiac arrest database registered in Bao'an District of Shenzhen City from March 1, 2019 to February 29, 2020 were included in a retrospective observational study. The AED coverage of public and non-public areas was analyzed by calculating the minimum distance between the occurrence place of each OHCA event and the nearest AED. The minimum distance ≤ 100 m was set as AED coverage, and the minimum distance > 100 m was set as non-AED coverage. It was assumed that one AED was configured for each OHCA hotspot area, then the AED coverage changes were analyzed. Based on the actual situation that the AED in schools, governments, sports venues, subways, tourist attractions and parks of public areas in Bao'an District could not be obtained at any time within 24 hours, it was assumed that all AED in the public areas could be obtained at any time within 24 hours, the impact of AED available at any time on AED coverage was analyzed.
RESULTS: A total of 525 cases of OHCA were enrolled. The highest incidence of OHCA was found in residential and industrial areas [54.5% (286/525) and 14.3% (75/525), respectively]. There were 252 AED in Bao'an District, Shenzhen, and 115 OHCA events occurred within the coverage area of AED. Even if all AED met the ideal state that could be obtained at any time within 24 hours, the coverage rate was only 21.9% (115/525). The AED coverage rate of the public areas and non-public areas was 31.6% (37/117) and 19.1% (78/408) respectively, with uneven distribution, and the AED coverage rate of non-public areas was low. Assuming that the residential community and industrial zone with more than 2 OHCA cases were respectively equipped with one AED, the coverage rate of AED in the non-public areas increased from 19.1% (78/408) to 28.2% (115/408), basically meeting the requirement that AED could be obtained at any time when OHCA events occurred. Some AED in the public areas of Bao'an District were not available at any time within 24 hours. If the ideal state that all AED in the public area could be obtained at any time within 24 hours could be achieved, the AED coverage rate of all regions increased from 16.8% (88/525) to 21.9% (115/525), the AED coverage rate of the public areas increased from 29.1% (34/117) to 31.6% (37/117), the AED coverage rate of the non-public areas increased from 13.2% (54/408) to 19.1% (78/408).
CONCLUSIONS: AED configuration in Bao'an District was unevenly distributed, and the coverage rate of AED in non-public areas was low. The allocation strategy for AED in fast-growing cities like Shenzhen should be as follows: on the premise of ensuring AED availability for 24 hours, priority should be given to covering the number of AED in the non-public areas including residential communities and industrial zones; AED is available in the public areas for 24 hours.
参考来源
- Gu Y, Zhang W, Wei J, et al. [Discussion on automated external defibrillator configuration optimization strategy of rapidly developing city: a case study of Bao'an, Shenzhen]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2022. PMID: 35307060. doi:10.3760/cma.j.cn121430-20210903-01316
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。