文献速递复苏、休克与脓毒症心脑血管急症重症综合管理与镇静镇痛

ICU内心脏骤停的复苏质量:一项回顾性分析

Resuscitation Quality in the ICU: A Retrospective Analysis.
PubMed 文献 · Chest · 2022-03-17
一句话结论在2006至2018年间,美国538家医院ICU内心脏骤停患者对AHA复苏质量指标的依从性较高,但除颤时间≤2分钟的依从性仅从72%升至75%,且夜间骤停、非目击、非监护及非心脏或创伤病因与依从失败相关。

该回顾性分析利用Get With The Guidelines-Resuscitation登记数据库,纳入美国538家医院2006至2018年间成人ICU内发生索引心脏骤停的患者,最终分析75,668例。主要评估对AHA三项复苏质量指标(肾上腺素给药≤5分钟、除颤≤2分钟、确认气道装置位于气管内)的依从趋势及失败预测因素。结果显示,肾上腺素及时给药依从性从93%升至98%,气道确认从93%升至97%,但除颤≤2分钟仅从72%升至75%,且除颤依从失败与夜间骤停、非心脏或创伤病因、肾功能不全相关。研究提示ICU内除颤及时性仍是复苏质量短板,需针对可干预因素改进。

要点

  • 2006至2018年,ICU内肾上腺素给药≤5分钟的依从性从93%(95%CI 93-94)升至98%(95%CI 97-98),气道装置气管内确认从93%(95%CI 91-94)升至97%(95%CI 96-98)。
  • 除颤≤2分钟的依从性仅从72%(95%CI 69-75)升至75%(95%CI 72-78),在ICU三项质量指标中最低。
  • 非目击骤停(P < .001)、非监护状态(P = .003)和夜间骤停(P = .002)与肾上腺素给药≤5分钟依从失败相关。
  • 非心脏病因(P < .001)、创伤病因(P < .001)、肾功能不全(P = .001)和夜间骤停(P = .03)与除颤≤2分钟依从失败相关。
  • ICU内复苏质量指标总体依从性高,但除颤及时性需针对性改进。

适用人群与场景

  • 2006至2018年间美国538家医院成人ICU内发生索引心脏骤停的成年患者,共识别97,009例,最终分析75,668例。

诊断标准与关键阈值

  • 美国心脏协会复苏质量指标:肾上腺素给药时间≤5分钟、除颤时间≤2分钟、确认气道装置位于气管内。

红旗征与不能漏的情况

  • 非目击骤停(P < .001)、非监护状态(P = .003)和夜间骤停(P = .002)与肾上腺素给药≤5分钟依从失败相关。
  • 非心脏病因(P < .001)、创伤病因(P < .001)、肾功能不全(P = .001)和夜间骤停(P = .03)与除颤≤2分钟依从失败相关。

研究设计与关键结果

  • 研究类型为回顾性分析,使用Get With The Guidelines-Resuscitation登记数据库,纳入2006至2018年美国538家医院成人ICU的97,009例索引心脏骤停患者,最终分析75,668例,采用改良泊松回归和广义估计方程分析。
  • 肾上腺素给药≤5分钟依从性从2006年93%(95%CI 93-94)升至2018年98%(95%CI 97-98)。
  • 除颤≤2分钟依从性从2006年72%(95%CI 69-75)升至2018年75%(95%CI 72-78)。
  • 气道装置气管内确认依从性从2006年93%(95%CI 91-94)升至2018年97%(95%CI 96-98)。
  • 非目击状态(P < .001)、非监护状态(P = .003)、夜间骤停(P = .002)与肾上腺素给药≤5分钟依从失败相关;非心脏病因(P < .001)、创伤病因(P < .001)、肾功能不全(P = .001)、夜间骤停(P = .03)与除颤≤2分钟依从失败相关。

证据类型、等级与局限

  • 证据类型:回顾性分析,基于Get With The Guidelines-Resuscitation登记数据库。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 原文结论未据此给出推荐;研究显示ICU内对肾上腺素给药≤5分钟和气道确认的依从性高,但除颤≤2分钟的依从性仅从72%升至75%,且与非心脏或创伤病因、肾功能不全、夜间骤停等因素相关。

指南或共识出处

  • 美国心脏协会复苏质量指标(肾上腺素给药≤5分钟、除颤≤2分钟、确认气道装置位于气管内)。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: American Heart Association quality metrics of resuscitation include time to epinephrine ≤ 5 min, time to defibrillation ≤ 2 min, and confirmation of airway device placement in trachea. This study examined trends in adherence to these quality metrics in the ICU and identified predictors of failure to adhere to these metrics.

RESEARCH QUESTION: What is the registered adherence to time to epinephrine ≤ 5 min, time to defibrillation ≤ 2 min, and confirmation of airway device placement in trachea in the ICU setting?

STUDY DESIGN AND METHODS: This was a retrospective analysis. Using the Get With The Guidelines-Resuscitation registry, adult patients with an index cardiac arrest in adult ICUs between 2006 and 2018 in the United States were identified. Modified Poisson regression with generalized estimation equations were used for the analyses.

RESULTS: A total of 97,009 adult ICU patients from 538 hospitals were identified using the Get With The Guidelines-Resuscitation registry, and 75,668 patients were included in the final analysis. From 2006 to 2018, adherence to time to epinephrine ≤ 5 min increased from 93% (95% CI, 93-94) to 98% (95% CI, 97-98), time to defibrillation ≤ 2 min increased from 72% (95% CI, 69-75) to 75% (95% CI, 72-78), and confirmation of airway device placement in trachea increased from 93% (95% CI, 91-94) to 97% (95% CI, 96-98). Nonwitnessed status (P < .001), nonmonitored status (P = .003), and nighttime arrest (P = .002) were associated with adherence failure for time to epinephrine ≤ 5 min, whereas a noncardiac (P < .001) or traumatic (P < .001) illness category, renal insufficiency (P = .001), and nighttime arrest (P = .03) were associated with adherence failure for time to defibrillation ≤ 2 min.

INTERPRETATION: Overall, quality metric adherence was high in the ICU, with the exception of time to defibrillation ≤ 2 min.

来源:Chest,查看原文。版权归原作者所有。

参考来源

  1. Roessler LL, Holmberg MJ, Pawar RD, et al. Resuscitation Quality in the ICU: A Retrospective Analysis. Chest. 2022. PMID: 35305970. doi:10.1016/j.chest.2022.03.015

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。