文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

宏基因组二代测序检测器官移植合并肺部感染患者支气管肺泡灌洗液病原体的诊断价值

[Diagnostic value of detection of pathogens in bronchoalveolar lavage fluid by metagenomics next-generation sequencing in organ transplant patients with pulmonary infection].
PubMed 文献 · Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · 2021-01-01
一句话结论在ICU实体器官移植合并肺部感染患者中,支气管肺泡灌洗液mNGS较常规综合微生物检测显著提高细菌阳性检出率(OR=5.5,P=0.02),并在病毒检测和混合感染识别方面具有明显优势。

该回顾性研究纳入2018年8月至2021年8月中国科学技术大学附属第一医院重症医学科收治的46例器官移植后肺炎/疑似肺炎患者,收集支气管肺泡灌洗液同步行mNGS和常规综合微生物检测(CMT),以CMT为参考标准比较诊断价值。35例患者共检出31种病原体,包括细菌16种、真菌9种、病毒6种;mNGS和CMT共同检出25种,仅mNGS检出19种。细菌检测方面mNGS阳性样本比例显著高于CMT(OR=5.5,95%CI 1.2-24.8,P=0.02),敏感度93.3%、特异度50.0%、阳性预测值58.3%、阴性预测值91.1%。真菌检测两法阳性比例无显著差异(OR=1.5,95%CI 0.5-4.2,P=0.60);23例(65.7%)诊断为肺部混合感染。mNGS可提高危重器官移植患者肺部感染细菌鉴定的敏感度和特异度,在病毒检测和混合感染识别方面优势明显。

要点

  • 35例检出病原体的患者中,mNGS检出25种、CMT检出25种,仅mNGS检出19种病原体。
  • 细菌检测:35份样本CMT阴性20例,其中mNGS检出阳性10例,mNGS阳性比例显著高于CMT(OR=5.5,95%CI 1.2-24.8,P=0.02)。
  • 以CMT为参考,mNGS细菌检测敏感度93.3%、特异度50.0%、阳性预测值58.3%、阴性预测值91.1%。
  • 真菌检测两法阳性比例无显著差异(OR=1.5,95%CI 0.5-4.2,P=0.60),mNGS敏感度72.2%、特异度64.7%。
  • 20例病毒阳性,最常见为巨细胞病毒28.6%(10/35)、疱疹病毒20.0%(7/35)、EB病毒17.1%(6/35);23例(65.7%)诊断为肺部混合感染。

适用人群与场景

  • 中国科学技术大学附属第一医院重症医学科2018年8月至2021年8月收治的器官移植后肺炎/疑似肺炎患者,共46例,采集支气管肺泡灌洗液样本。

研究设计与关键结果

  • 回顾性研究,纳入46例器官移植后肺炎/疑似肺炎患者,支气管肺泡灌洗液同步行mNGS和常规综合微生物检测(CMT),以CMT为参考标准。
  • 35例患者共检出31种病原体:细菌16种、真菌9种、病毒6种;mNGS和CMT共同检出25种,仅mNGS检出19种。
  • mNGS检出率:铜绿假单胞菌51.4%(18/35)、鲍曼不动杆菌42.9%(15/35)、肺炎克雷伯菌31.4%(11/35);白念珠菌31.4%(11/35)、曲霉22.9%(8/35)、卡氏肺孢子虫22.9%(8/35);病毒阳性20例,巨细胞病毒28.6%(10/35)、疱疹病毒20.0%(7/35)、EB病毒17.1%(6/35);另检出1例布鲁菌。
  • 细菌检测:35份样本CMT阴性20例,mNGS在阴性样本中检出阳性10例,mNGS阳性比例显著高于CMT(OR=5.5,95%CI 1.2-24.8,P=0.02);mNGS敏感度93.3%、特异度50.0%、阳性预测值58.3%、阴性预测值91.1%。
  • 真菌检测:两法阳性比例无显著差异(OR=1.5,95%CI 0.5-4.2,P=0.60);mNGS敏感度72.2%、特异度64.7%、阳性预测值68.4%、阴性预测值68.8%;35份样本CMT阴性17例,mNGS在阴性样本中检出阳性6例。
  • 20例患者mNGS病毒检测阳性;23例(65.7%)诊断为肺部混合感染。

证据类型、等级与局限

  • 证据类型:回顾性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,采用mNGS检测支气管肺泡灌洗液病原体可提高危重器官移植患者肺部感染细菌鉴定的敏感度和特异度,并在病毒检测和混合感染识别方面具有明显优势。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic value of metagenomics next-generation sequencing (mNGS) in detecting pathogens in bronchoalveolar lavage fluid (BALF) for pulmonary infection in solid organ transplant patients in intensive care unit (ICU).

METHODS: A retrospective study was conducted, the BALF samples from 46 patients with post organ transplant pneumonia/suspected pneumonia admitted to the Department of Critical Care Medicine of the First Affiliated Hospital of University of Science and Technology of China from August 2018 to August 2021 were collected, all tested by simultaneous mNGS and conventional comprehensive microbial test (CMT), and the results of CMT were used as the reference standard to compare the differences in the diagnostic value of mNGS and CMT for pulmonary infections in solid organ transplant patients, and to analyze the diagnostic value of mNGS for mixed infections.

RESULTS: (1) Pneumonia pathogens: a total of 31 pathogens were detected in 35 patients, including bacteria (16 species), fungi (9 species) and viruses (6 species). Among them, 25 pathogens were detected by mNGS and CMT, and only 19 pathogens were detected by mNGS. Among the microorganisms isolated by mNGS method, the detection rates of Pseudomonas aeruginosa, Acinetobacter baumannii and Klebsiella pneumoniae were higher [51.4% (18/35), 42.9% (15/35), 31.4% (11/35), respectively]; Candida albicans, Aspergillus and Pneumocystis carinii were the most commonly detected fungi [31.4% (11/35), 22.9% (8/35), 22.9% (8/35), respectively]; 20 patients were positive for the virus, and the most commonly detected viruses were cytomegalovirus, herpesvirus and EB virus [28.6% (10/35), 20.0% (7/35), 17.1% (6/35), respectively]. In addition, one case of Brucella was detected by mNGS. (2) Diagnostic efficiency: as far as bacterial detection is concerned, 20 cases of negative results were obtained by CMT detection of 35 samples included in the study, and a total of 10 cases of positive results were obtained by mNGS detection of negative samples; the percentage of mNGS positive samples was significantly higher than that of CMT positive samples [odds ratio (OR) = 5.5, 95% confidence interval (95%CI) = 1.2-24.8, P = 0.02]. When compared with CMT, the sensitivity and specificity of mNGS were 93.3% and 50.0%, and the positive predictive value (PPV) and negative predictive value (NPV) were 58.3%, 91.1%. As far as fungal detection was concerned, there was no significant difference in the percentage of positive samples between the two methods (OR = 1.5, 95%CI = 0.5-4.2, P = 0.60); the sensitivity and specificity of mNGS were 72.2% and 64.7%, and the PPV and NPV were 68.4%, 68.8%; CMT test of the 35 included samples produced 17 negative results, and mNGS test of the negative samples produced 6 positive results. A total of 20 patients tested positive for the virus by mNGS. In addition, 23 patients (65.7%) were diagnosed with pulmonary mixed infection.

CONCLUSIONS: The use of mNGS to detect pathogens in BALF can improve the sensitivity and specificity of bacterial identification of pulmonary infection in critically ill organ transplant patients, and mNGS has obvious advantages in detecting virus and identifying mixed infections.

来源:Zhonghua Wei Zhong Bing Ji Jiu Yi Xue,查看原文。版权归原作者所有。

参考来源

  1. Meng X, Zhang L, Fan X, et al. [Diagnostic value of detection of pathogens in bronchoalveolar lavage fluid by metagenomics next-generation sequencing in organ transplant patients with pulmonary infection]. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2021. PMID: 35131010. doi:10.3760/cma.j.cn121430-20211008-01439

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。