文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

控制机械通气时肺充气对右心室负荷的影响

Right Ventricular Loading by Lung Inflation during Controlled Mechanical Ventilation.
PubMed 文献 · Am J Respir Crit Care Med · 2022-01-01
一句话结论术后被动通气患者中,潮气量≥6 ml/kg PBW时超半数出现非3区条件,右心室后负荷随潮气量增加而增加。

研究在51例术后被动通气的的心脏手术患者中,通过右房、右室、肺动脉、肺动脉闭塞压、平台压和食管压测量,并在2至12 ml/kg PBW范围内递增潮气量,评估吸气时右心室后负荷增加。结果显示潮气量、驱动压、跨肺压与右心室等容收缩压的吸气增加呈线性关系;超声显示潮气量增加与后负荷标志物吸气增加及每搏输出量下降相关。潮气量≥6 ml/kg PBW时超过50%受试者存在非3区条件。结论认为在当前处方的潮气量范围内,右心室后负荷随潮气量增加而增加,限制潮气量和驱动压的机械通气策略具有心脏保护作用。

要点

  • 在51例术后被动通气的心脏手术患者中,潮气量、驱动压、跨肺压与右心室等容收缩压的吸气增加呈线性关系。
  • 超声显示潮气量增加与后负荷标志物吸气增加及每搏输出量下降相关。
  • 潮气量≥6 ml/kg PBW时,超过50%受试者存在非3区条件。
  • 结论认为限制潮气量和驱动压的机械通气策略具有心脏保护作用。

适用人群与场景

  • 术后被动通气的的心脏手术患者,潮气量在2至12 ml/kg PBW范围内调整。

诊断标准与关键阈值

  • 非3区条件基于食管压、肺动脉闭塞压和平台压变化采用两种定义判定。

研究设计与关键结果

  • 研究类型为在术后被动通气的心脏手术患者中进行的生理学研究,共51例。
  • 潮气量、驱动压、跨肺压与右心室等容收缩压的吸气增加呈线性关系。
  • 超声显示潮气量增加与后负荷标志物吸气增加及每搏输出量下降相关。
  • 潮气量≥6 ml/kg PBW时,超过50%受试者存在非3区条件。

证据类型、等级与局限

  • 证据类型:生理学研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,限制潮气量和驱动压的机械通气策略具有心脏保护作用。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rationale: The inspiratory rise in transpulmonary pressure during mechanical ventilation increases right ventricular (RV) afterload. One mechanism is that when Palv exceeds left atrial pressure, West zone 1 or 2 (non-zone 3) conditions develop, and Palv becomes the downstream pressure opposing RV ejection. The Vt at which this impact on the right ventricle becomes hemodynamically evident is not well established. Objectives: To determine the magnitude of RV afterload and prevalence of significant non-zone 3 conditions during inspiration across the range of Vt currently prescribed in clinical practice. Methods: In postoperative passively ventilated cardiac surgery patients, we measured right atrial, right ventricle, pulmonary artery, pulmonary artery occlusion pressure, plateau pressure, and esophageal pressure during short periods of controlled ventilation, with Vt increments ranging between 2 and 12 ml/kg predicted body weight (PBW). The inspiratory increase in RV afterload was evaluated hemodynamically and echocardiographically. The prevalence of non-zone 3 conditions was determined using two definitions based on changes in esophageal pressure, pulmonary artery occlusion pressure, and plateau pressure. Measurements and Main Results: Fifty-one patients were studied. There was a linear relationship between Vt, driving pressure, transpulmonary pressure, and the inspiratory increase in the RV isovolumetric contraction pressure. Echocardiographically, increasing Vt was associated with a greater inspiratory increase in markers of afterload and a decrease in stroke volume. Non-zone 3 conditions were present in >50% of subjects at a Vt ⩾ 6 ml/kg PBW. Conclusions: In the Vt range currently prescribed, RV afterload increases with increasing Vt. A mechanical ventilation strategy that limits Vt and driving pressure is cardioprotective.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Slobod D, Assanangkornchai N, Alhazza M, et al. Right Ventricular Loading by Lung Inflation during Controlled Mechanical Ventilation. Am J Respir Crit Care Med. 2022. PMID: 35213296. doi:10.1164/rccm.202111-2483OC

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。