床旁超声评估脓毒性休克患者心输出量与容量反应性的临床价值
研究纳入郑州大学人民医院(河南省人民医院)重症医学科2020年11月25日至2021年4月30日需PiCCO监测的24例脓毒性休克机械通气患者,以PiCCO为标准,在0、2、6、12、24、48小时同步用床旁经胸超声心动图测VTI与下腔静脉直径(dIVC),计算CO、ΔVTI、ΔdIVC并做一致性与相关性分析。24例中22例获得满意超声多普勒图像;随治疗时间延长HR与CO逐渐下降、MAP逐渐升高,48小时达峰或谷。PiCCO与床旁超声CO一致性良好(rs=0.800,P<0.001);PiCCO的SVV与超声ΔdIVC中度相关(rs=0.702,P<0.001),与ΔVTI高度相关(rs=0.918,P<0.001)。作者认为床旁超声能准确评估脓毒性休克患者的CO与容量反应性,ΔVTI评估容量反应性优于ΔdIVC。
要点
- 以PiCCO为标准,床旁超声CO与PiCCO一致性良好:平均差值(-0.02±0.69) L/min,95%一致性界限-1.35~1.34,rs=0.800(P<0.001)。
- 容量反应性评估中ΔVTI与PiCCO的SVV高度相关(rs=0.918,P<0.001),ΔdIVC仅中度相关(rs=0.702,P<0.001),作者认为ΔVTI优于ΔdIVC。
- ΔVTI与SVV平均差值(13.03±14.75)%、95%一致性界限1.72~27.78;ΔdIVC与SVV平均差值(-3.16±6.89)%、95%一致性界限-16.89~10.54。
- 24例中22例获得满意超声多普勒图像,床旁超声评估需以可获得满意图像为前提。
- 随治疗时间延长HR、CO逐渐下降,MAP逐渐升高,48小时达峰或谷:HR 90.36±15.35 vs. 116.82±19.82 bpm,MAP 87.82±11.06 vs. 58.82±9.85 mmHg,CO 4.80±0.56 vs. 6.78±1.31 L/min,均P<0.05。
适用人群与场景
- 郑州大学人民医院(河南省人民医院)重症医学科2020年11月25日至2021年4月30日收治的需PiCCO监测的脓毒性休克机械通气患者24例,最终22例获得满意超声多普勒图像。
处置流程与药物剂量
- 以PiCCO为标准,在0、2、6、12、24、48小时监测CO与每搏变异度(SVV)。
- 同期用床旁经胸超声心动图(TTE)测速度时间积分(VTI)与下腔静脉直径(dIVC),计算CO、VTI变异率(ΔVTI)与dIVC变异率(ΔdIVC)。
- 以PiCCO监测值为标准,将床旁超声测得指标与PiCCO做一致性与相关性分析。
研究设计与关键结果
- 单中心研究,纳入24例脓毒性休克机械通气患者,22例获得满意超声多普勒图像;入组患者心率、平均动脉压与体温符合脓毒性休克病理生理特征。
- 随治疗时间延长HR与CO逐渐下降、MAP逐渐升高,48小时达峰或谷,与入科时比较差异有统计学意义:HR(bpm)90.36±15.35 vs. 116.82±19.82,MAP(mmHg)87.82±11.06 vs. 58.82±9.85,CO(L/min)4.80±0.56 vs. 6.78±1.31,均P<0.05。
- PiCCO与床旁超声CO一致性良好:分别为5.36(4.78,6.33)L/min与5.21(4.88,6.35)L/min,各时间点平均差值(-0.02±0.69) L/min,95%一致性界限-1.35~1.34,高度相关(rs=0.800,P<0.001)。
- PiCCO的SVV与床旁超声ΔdIVC一致性良好:分别为18.00%(14.00%,24.00%)与21.00%(14.00%,25.75%),时间点平均差值(-3.16±6.89)%,95%一致性界限-16.89~10.54,中度相关(rs=0.702,P<0.001)。
- PiCCO的SVV与床旁超声ΔVTI一致性良好:分别为18.00%(14.00%,24.00%)与16.00%(11.25%,20.75%),各时间点平均差值(13.03±14.75)%,95%一致性界限1.72~27.78,高度相关(rs=0.918,P<0.001)。
证据类型、等级与局限
- 研究类型:单中心临床研究(原文标注为Zhonghua Wei Zhong Bing Ji Jiu Yi Xue刊载的论著摘要),样本量24例、其中22例获得满意超声图像。
- 作者结论:床旁超声能准确评估脓毒性休克患者的CO与容量反应性,ΔVTI评估容量反应性优于ΔdIVC。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,床旁超声可准确评估脓毒性休克机械通气患者的CO与容量反应性,可作为PiCCO之外的无创评估手段。
- 作者认为,评估容量反应性时ΔVTI优于ΔdIVC。
- 本组24例中2例未获得满意超声多普勒图像,床旁超声评估依赖可获得满意图像。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the value of point of care ultrasound on cardiac output (CO) and volume responsiveness in patients with septic shock.
METHODS: Twenty-four mechanical ventilation patients with septic shock who needed pulse-indicated continuous cardiac output (PiCCO) monitoring in the department of critical care medicine of Zhengzhou University People's Hospital, Henan Provincial People's Hospital from November 25, 2020 to April 30, 2021 were selected as the subjects, the patient's basic information and laboratory test results were recorded. PiCCO was used as standard to monitor CO and stroke volume variability (SVV) at 0, 2, 6, 12, 24 and 48 hours. At the same time, point of care transthoracic echocardiography (TTE) was used to measure velocity time integral (VTI) and inferior vena cava diameter (dIVC), the CO, VTI variation rate (ΔVTI) and dIVC variation rate (ΔdIVC) were calculated. Then, using the value monitored by PiCCO as the standard, the consistency and correlation analysis were carried out between point of care ultrasound with PiCCO.
RESULTS: Twenty-two out of 24 patients obtained satisfactory ultrasound Doppler images, the heart rate (HR), mean arterial pressure (MAP) and body temperature of the enrolled patients were consistent with the pathophysiological characteristics of septic shock. With the extension of treatment time, HR and CO both gradually decreased, and MAP gradually increased, reaching a peak or trough at 48 hours after admission. The difference were statistically significant compared with the time of admission [HR (bpm): 90.36±15.35 vs. 116.82±19.82, MAP (mmHg, 1 mmHg = 0.133 kPa): 87.82±11.06 vs. 58.82±9.85, CO (L/min): 4.80±0.56 vs. 6.78±1.31, all P < 0.05]. The CO obtained by PiCCO and point of care ultrasound had good agreement [5.36 (4.78, 6.33) L/min and 5.21 (4.88, 6.35) L/min, respectively], the average difference value at each time point was (-0.02±0.69) L/min, the 95% agreement limit range was -1.35-1.34, and there was a high degree of correlation (rs = 0.800, P < 0.001); The SVV by PiCCO and the ΔdIVC by point of care ultrasound were in good agreement [18.00% (14.00%, 24.00%) and 21.00% (14.00%, 25.75%), respectively], the average difference value at the time point was (-3.16±6.89)%, the 95% agreement limit range was -16.89-10.54, and there was a moderate correlation (rs = 0.702, P < 0.001); The SVV by PiCCO and the ΔVTI by point of care ultrasound were in good agreement [18.00% (14.00%, 24.00%) and 16.00% (11.25%, 20.75%), respectively], the average difference value at each time point was (13.03±14.75)%, and the 95% agreement limit range was 1.72-27.78, and there was a high correlation (rs = 0.918, P < 0.001).
CONCLUSIONS: Point of care ultrasound can accurately assess CO and volume responsiveness of patients with septic shock, and the ΔVTI is better than the ΔdIVC in assessing volume responsiveness.