一句话结论模拟儿童心肺复苏中,按压深度目标表述为「至少胸部前后径的三分之一」比「5 cm」能达到更深按压和更高按压充分性。

这项前瞻性随机交叉模拟试验让32名医生在儿童模拟人上分别采用单手(OHCC)或双手(THCC)胸外按压技术,按「5 cm」(试验1)或「至少胸部前后径的三分之一」(试验2)的按压深度目标进行2分钟单人心肺复苏,顺序随机。结果显示两种技术下试验1的平均按压深度均显著低于试验2(OHCC:50.0 mm vs 52.0 mm,P=0.001;THCC:52.0 mm vs 58.0 mm,P<0.001),按压充分性试验2也优于试验1(OHCC:63.0% vs 96.5%,P<0.001;THCC:96.5% vs 100.0%,P<0.001)。通气参数在两试验间无显著差异。提示复苏指南中按压深度目标的表述方式可能影响儿童心肺复苏的按压质量。

要点

  • 模拟儿童CPR中,按压深度目标「5 cm」组平均按压深度显著低于「至少胸部前后径三分之一」组(OHCC:50.0 mm vs 52.0 mm,P=0.001;THCC:52.0 mm vs 58.0 mm,P<0.001)。
  • 按压充分性「至少胸部前后径三分之一」组优于「5 cm」组(OHCC:63.0% vs 96.5%,P<0.001;THCC:96.5% vs 100.0%,P<0.001)。
  • 通气参数在「5 cm」与「至少胸部前后径三分之一」两组间无显著差异。
  • 研究为前瞻性随机交叉模拟试验,32名医生在儿童模拟人上完成2分钟单人CPR。

适用人群与场景

  • 32名医生在儿童模拟人上实施2分钟单人 CPR,采用单手(OHCC)或双手(THCC)胸外按压技术。

研究设计与关键结果

  • 前瞻性随机交叉模拟试验,32名医生在儿童模拟人上按随机顺序以「5 cm」(试验1)或「至少胸部前后径的三分之一」(试验2)为按压深度目标实施2分钟单人CPR。
  • OHCC平均按压深度:试验1为50.0 mm(46.0-52.0 mm),试验2为52.0 mm(50.3-55.0 mm),P=0.001。
  • THCC平均按压深度:试验1为52.0 mm(50.3-55.0 mm),试验2为58.0 mm(54.0-62.0 mm),P<0.001。
  • OHCC按压充分性:试验1为63.0%(7.5-95.8%),试验2为96.5%(78.8-99.9%),P<0.001。
  • THCC按压充分性:试验1为96.5%(78.8-99.9%),试验2为100.0%(100.0-100.0%),P<0.001。
  • 通气参数在试验1与试验2之间无显著差异。

证据类型、等级与局限

  • 证据类型:前瞻性随机交叉模拟试验。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 在儿童模拟 CPR 中,采用「至少胸部前后径的三分之一」作为按压深度目标时,单手和双手按压技术的平均按压深度及按压充分性均高于「5 cm」目标。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to investigate the effect of resuscitation guideline terminology on pediatric cardiopulmonary resuscitation (CPR) performance.

METHODS: This was a prospective randomised crossover simulation trial. A total of 32 medical doctors conducted 2-min single-rescuer CPR using the one-handed chest compression technique (OHCC) or two-handed chest compression technique (THCC) on a pediatric manikin. The participants conducted chest compressions according to the chest compression depth (CCD) target of '5 cm (Test 1)' or 'at least one third of the anterior-posterior dimension of the chest (Test 2)' in a random order.

RESULTS: In both techniques (OHCC or THCC), the average CCD of Test 1 were significantly lower than those of Test 2 (OHCC: 50.0 mm [46.0-52.0 mm] in Test 1 vs. 52.0 mm [50.3-55.0 mm] in Test 2, P = 0.001; THCC: 52.0 mm [50.3-55.0 mm] in Test 1 vs. 58.0 mm [54.0-62.0 mm] in Test 2, P < 0.001). The adequacy of the chest compressions was also superior in Test 2 (OHCC: 63.0% [7.5-95.8%] in Test 1 vs. 96.5% [78.8-99.9%] in Test 2, P < 0.001; THCC: 96.5% [78.8-99.9%] in Test 1 vs. 100.0% [100.0-100.0%] in Test 2, P < 0.001). Ventilation parameters were not significantly different between Tests 1 and 2.

CONCLUSIONS: Average CCD during simulated pediatric CPR according to the CCD target of '5 cm' was significantly lower than those according to the CCD target of 'at least one third of the anterior-posterior dimension of the chest'.