股动脉多普勒超声在心脏骤停中检测脉搏比手动触诊更准确
本研究为前瞻性、横断面、诊断准确性研究,纳入急诊科成人心脏骤停患者便利样本,所有患者均置有股动脉导管。在脉搏检查时记录手动触诊、多普勒超声收缩期峰值流速(PSV)及收缩压(SBP)。共分析54例患者、213次脉搏检查。多普勒超声检测任何脉搏的准确率高于手动触诊(95.3% vs 54.0%,p<0.001);PSV与SBP强相关(Spearman相关系数=0.89,p<0.001);与SBP≥60 mmHg相关的最佳PSV截断值为20 cm/s(曲线下面积=0.975);以PSV≥20 cm/s检测SBP≥60 mmHg的准确率高于手动触诊(91.4% vs 66.2%,p<0.001)。
要点
- 在急诊科成人心脏骤停患者中,股动脉多普勒超声检测任何脉搏的准确率为95.3%,高于手动触诊的54.0%(p<0.001)。
- 多普勒超声PSV与有创SBP强相关(Spearman相关系数=0.89,p<0.001)。
- 与SBP≥60 mmHg相关的最佳PSV截断值为20 cm/s,曲线下面积=0.975。
- 以PSV≥20 cm/s检测SBP≥60 mmHg的准确率为91.4%,高于手动触诊的66.2%(p<0.001)。
适用人群与场景
- 急诊科成人心脏骤停患者,便利样本,所有患者均置有股动脉导管。
诊断标准与关键阈值
- 以多普勒超声收缩期峰值流速(PSV)≥20 cm/s作为检测收缩压(SBP)≥60 mmHg的最佳截断值(曲线下面积=0.975)。
研究设计与关键结果
- 研究类型:前瞻性、横断面、诊断准确性研究;样本量:54例患者、213次脉搏检查;人群:急诊科成人心脏骤停患者,均置有股动脉导管。
- 多普勒超声检测任何脉搏的准确率为95.3%,手动触诊为54.0%,多普勒超声更高(p<0.001)。
- PSV与SBP强相关(Spearman相关系数=0.89,p<0.001)。
- 与SBP≥60 mmHg相关的最佳PSV截断值为20 cm/s(曲线下面积=0.975)。
- 以PSV≥20 cm/s检测SBP≥60 mmHg的准确率为91.4%,手动触诊为66.2%,多普勒超声更高(p<0.001)。
证据类型、等级与局限
- 证据类型:前瞻性、横断面、诊断准确性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 在急诊科成人心脏骤停患者中,股动脉多普勒超声检测任何脉搏比手动触诊更准确;使用PSV≥20 cm/s时,多普勒超声检测SBP≥60 mmHg也比手动触诊更准确。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVES: Our primary objective was to assess the accuracy of Doppler ultrasound versus manual palpation in detecting any pulse with an arterial line waveform in cardiac arrest. Secondarily, we sought to determine whether peak systolic velocity (PSV) on Doppler ultrasound could detect a pulse with a systolic blood pressure (SBP) ≥ 60 mmHg.
METHODS: We conducted a prospective, cross-sectional, diagnostic accuracy study on a convenience sample of adult, Emergency Department (ED) cardiac arrest patients. All patients had a femoral arterial line. During a pulse check, manual pulse detection, PSV and Doppler ultrasound clips, and SBP were recorded. A receiver operator characteristic curve analysis was performed to determine the optimal cut-off of PSV associated with a SBP ≥ 60 mmHg. Accuracy of manual palpation and Doppler ultrasound for detection of any pulse and SBP ≥ 60 mmHg were compared with McNemar's test.
RESULTS: 54 patients and 213 pulse checks were analysed. Doppler ultrasound demonstrated higher accuracy than manual palpation (95.3% vs. 54.0%; p < 0.001) for detection of any pulse. Correlation between PSV and SBP was strong (Spearman correlation coefficient = 0.89; p < 0.001). The optimal cut-off value of PSV associated with a SBP ≥ 60 mmHg was 20 cm/s (area under the curve = 0.975). To detect SBP ≥ 60 mmHg, accuracy of a PSV ≥ 20 cm/s was higher than manual palpation (91.4% vs. 66.2%; p < 0.001).
CONCLUSIONS: Among ED cardiac arrest patients, femoral artery Doppler ultrasound was more accurate than manual palpation for detecting any pulse. When using a PSV ≥ 20 cm/s, Doppler ultrasound was also more accurate for detecting a SBP ≥ 60 mmHg.