一句话结论在压力支持通气中,Flow Index > 4.5 可识别高吸气努力(AUC 0.89),< 2.6 可识别低吸气努力(AUC 0.80)。

该研究分析 24 名压力支持通气受试者的 702 次呼吸,以吸气肌肉产生的压力(Pmusc)> 10 cmH2O 定义为高吸气努力、< 5 cmH2O 定义为低吸气努力,评估 Flow Index 识别高或低吸气努力的准确性并建立界值,同时与呼吸频率、潮气量、呼吸频率与潮气量比值及气道闭合压(P0.1)比较。结果显示 Flow Index > 4.5 识别高吸气努力(AUC 0.89,95%CI 0.85–0.93),Flow Index < 2.6 识别低吸气努力(AUC 0.80,95%CI 0.76–0.83);高、低和中间吸气努力呼吸之间的 Pmusc、P0.1、压力时间乘积和 Flow Index 存在差异,而呼吸频率、呼吸频率与潮气量比值及按理想体重计算的潮气量无统计学显著差异。结论认为 Flow Index 能准确检测压力支持通气时的高和低自主吸气努力。

要点

  • Flow Index > 4.5 识别高吸气努力(Pmusc > 10 cmH2O),AUC 0.89(95%CI 0.85–0.93)
  • Flow Index < 2.6 识别低吸气努力(Pmusc < 5 cmH2O),AUC 0.80(95%CI 0.76–0.83)
  • 高、低和中间吸气努力呼吸之间 Pmusc、P0.1、压力时间乘积和 Flow Index 存在差异
  • 呼吸频率、呼吸频率与潮气量比值及按理想体重计算的潮气量在高、低和中间吸气努力呼吸间无统计学显著差异
  • 研究共纳入 24 名受试者、702 次呼吸,Flow Index 为压力支持通气时吸气流量-时间波形形状的数值表达

适用人群与场景

  • 接受压力支持通气的受试者,共 24 名,分析 702 次呼吸

诊断标准与关键阈值

  • 高吸气努力定义为吸气肌肉产生的压力(Pmusc)> 10 cmH2O
  • 低吸气努力定义为 Pmusc < 5 cmH2O
  • Flow Index > 4.5 识别高吸气努力(AUC 0.89,95%CI 0.85–0.93)
  • Flow Index < 2.6 识别低吸气努力(AUC 0.80,95%CI 0.76–0.83)

研究设计与关键结果

  • 研究分析 24 名受试者的 702 次呼吸,比较高、低和中间吸气努力呼吸间 Flow Index、呼吸频率、潮气量、呼吸频率与潮气量比值及 P0.1 的差异并比较其 ROC 曲线下面积
  • Pmusc、P0.1、压力时间乘积和 Flow Index 在高、低和中间吸气努力呼吸间存在差异
  • 呼吸频率、呼吸频率与潮气量比值及按理想体重计算的潮气量在高、低和中间吸气努力呼吸间无统计学显著差异
  • Flow Index > 4.5 识别高吸气努力的 AUC 为 0.89(95%CI 0.85–0.93)
  • Flow Index < 2.6 识别低吸气努力的 AUC 为 0.80(95%CI 0.76–0.83)

证据类型、等级与局限

  • 纳入 24 名受试者、702 次呼吸

对床旁实践的改变

  • 作者认为 Flow Index 能准确检测压力支持通气时的高和低自主吸气努力

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Flow Index, a numerical expression of the shape of the inspiratory flow-time waveform recorded during pressure support ventilation, is associated with patient inspiratory effort. The aim of this study was to assess the accuracy of Flow Index in detecting high or low inspiratory effort during pressure support ventilation and to establish cutoff values for the Flow index to identify these conditions. The secondary aim was to compare the performance of Flow index,of breathing pattern parameters and of airway occlusion pressure (P0.1) in detecting high or low inspiratory effort during pressure support ventilation.

METHODS: Data from 24 subjects was included in the analysis, accounting for a total of 702 breaths. Breaths with high inspiratory effort were defined by a pressure developed by inspiratory muscles (Pmusc) greater than 10 cmH2O while breaths with low inspiratory effort were defined by a Pmusc lower than 5 cmH2O. The areas under the receiver operating characteristic curves of Flow Index and respiratory rate, tidal volume,respiratory rate over tidal volume and P0.1 were analyzed and compared to identify breaths with low or high inspiratory effort.

RESULTS: Pmusc, P0.1, Pressure Time Product and Flow Index differed between breaths with high, low and intermediate inspiratory effort, while RR, RR/VT and VT/kg of IBW did not differ in a statistically significant way. A Flow index higher than 4.5 identified breaths with high inspiratory effort [AUC 0.89 (CI 95% 0.85-0.93)], a Flow Index lower than 2.6 identified breaths with low inspiratory effort [AUC 0.80 (CI 95% 0.76-0.83)].

CONCLUSIONS: Flow Index is accurate in detecting high and low spontaneous inspiratory effort during pressure support ventilation.

来源:Crit Care,查看原文。版权归原作者所有。

参考来源

  1. Albani F, Fusina F, Ciabatti G, et al. Flow Index accurately identifies breaths with low or high inspiratory effort during pressure support ventilation. Crit Care. 2021. PMID: 34911541. doi:10.1186/s13054-021-03855-4

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。