创伤后隐匿性低灌注患者存在休克诱导的内皮功能障碍
本研究为单中心研究,纳入2012-2016年需最高级别创伤激活的患者520例,检测抵达创伤抢救室时血浆可溶性血栓调节蛋白(sTM)和syndecan-1(Syn-1)。结果显示35%患者存在隐匿性低灌注(OH),26%存在休克;正常灌注组sTM和Syn-1最低,OH和休克组升高。OH与sTM升高0.97 ng/mL(95% CI 0.39-1.57, p=0.001)相关,与Syn-1升高14.3 ng/mL(95% CI -1.5至30.2, p=0.08)相关;休克与sTM升高0.64(95% CI 0.02-1.30, p=0.04)和Syn-1升高23.6 ng/mL(95% CI 6.2-41.1, p=0.008)相关。作者认为,无论生命体征如何,有低灌注证据的创伤患者可能受益于稳定内皮的治疗。
要点
- 创伤后OH定义为收缩压≥90 mmHg、心率<120次/分且碱剩余≤-3,本队列中35%患者存在OH。
- OH与sTM升高0.97 ng/mL(95% CI 0.39-1.57, p=0.001)独立相关,提示内皮功能障碍。
- OH与Syn-1升高14.3 ng/mL(95% CI -1.5至30.2, p=0.08)相关,未达统计学显著。
- 休克与sTM升高0.64(95% CI 0.02-1.30, p=0.04)及Syn-1升高23.6 ng/mL(95% CI 6.2-41.1, p=0.008)相关。
- 正常灌注组sTM和Syn-1最低,OH和休克组升高。
适用人群与场景
- 2012-2016年单中心需最高级别创伤激活的创伤患者,共520例。
诊断标准与关键阈值
- 休克定义为收缩压<90 mmHg或心率≥120次/分。
- 隐匿性低灌注(OH)定义为收缩压≥90 mmHg、心率<120次/分且碱剩余≤-3。
- 正常灌注定义为不符合OH和休克标准的其余患者。
研究设计与关键结果
- 单中心研究纳入520例需最高级别创伤激活的患者,35%存在OH,26%存在休克。
- 正常灌注组sTM和Syn-1最低,OH和休克组升高。
- OH与sTM升高0.97 ng/mL(95% CI 0.39-1.57, p=0.001)相关,与Syn-1升高14.3 ng/mL(95% CI -1.5至30.2, p=0.08)相关。
- 休克与sTM升高0.64(95% CI 0.02-1.30, p=0.04)相关,与Syn-1升高23.6 ng/mL(95% CI 6.2-41.1, p=0.008)相关。
- 各组人口学特征相似。
证据类型、等级与局限
- 单中心研究,单因素和多因素分析。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,无论生命体征如何,有低灌注证据的创伤患者可能受益于稳定内皮的治疗。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
BACKGROUND: Shock-induced endothelial dysfunction, evidenced by elevated soluble thrombomodulin (sTM) and syndecan-1 (Syn-1), is associated with poor outcomes after trauma. The association of endothelial dysfunction and overt shock has been demonstrated; it is unknown if hypoperfusion in the setting of normal vital signs (occult hypoperfusion [OH]) is associated with endothelial dysfunction. We hypothesized that sTM and Syn-1 would be elevated in patients with OH when compared to patients with normal perfusion.
METHODS: A single-center study of patients requiring highest-level trauma activation (2012-2016) was performed. Trauma bay arrival plasma Syn-1 and sTM were measured by enzyme-linked immunosorbent assay. Shock was defined as systolic blood pressure (SBP) <90 mm Hg or heart rate (HR) ≥120 bpm. OH was defined as SBP ≥ 90, HR < 120, and base excess (BE) ≤-3. Normal perfusion was assigned to all others. Univariate and multivariable analyses were performed.
RESULTS: Of 520 patients, 35% presented with OH and 26% with shock. Demographics were similar between groups. Patients with normal perfusion had the lowest Syn-1 and sTM, while patients with OH and shock had elevated levels. OH was associated with increased sTM by 0.97 ng/mL (95% CI 0.39-1.57, p = 0.001) and Syn-1 by 14.3 ng/mL (95% CI -1.5 to 30.2, p = 0.08). Furthermore, shock was associated with increased sTM by 0.64 (95% CI 0.02-1.30, p = 0.04) and with increased Syn-1 by 23.6 ng/mL (95% CI 6.2-41.1, p = 0.008).
CONCLUSIONS: Arrival OH was associated with elevated sTM and Syn-1, indicating endothelial dysfunction. Treatments aiming to stabilize the endothelium may be beneficial for injured patients with evidence of hypoperfusion, regardless of vital signs.
参考来源
- Kregel HR, Hatton GE, Isbell KD, et al. Shock-Induced Endothelial Dysfunction is Present in Patients With Occult Hypoperfusion After Trauma. Shock. 2022. PMID: 34905531. doi:10.1097/SHK.0000000000001866
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。