文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

头盔无创通气中的气体调节:对舒适度、气体交换、吸气努力、跨肺压及人机交互的影响

Gas conditioning during helmet noninvasive ventilation: effect on comfort, gas exchange, inspiratory effort, transpulmonary pressure and patient-ventilator interaction.
PubMed 文献 · Ann Intensive Care · 2021-12-24
一句话结论在急性低氧性呼吸衰竭患者头盔无创通气1小时中,双管路无湿化可提供充分气体调节,舒适度最佳且人机交互改善;加热湿化器或热湿交换器因界面内过热过湿增加不适并加重呼吸困难。

本研究纳入20例急性低氧性呼吸衰竭(PaO2/FiO2<300 mmHg)患者,随机顺序接受头盔无创通气(PEEP 12 cmH2O,压力支持12 cmH2O)下四种湿化设置各1小时:双管路加热湿化器34°C(HH34)、37°C(HH37)、Y型管路热湿交换器(HME)、双管路无湿化(NoH)。结果显示NoH组绝对湿度、温度及不适VAS评分均显著低于HME、HH34和HH37组(绝对湿度16 vs 28 vs 28 vs 33 mgH2O/L,p<0.001;温度29 vs 30 vs 31 vs 32°C,p<0.001;不适VAS 4 vs 6 vs 7 vs 8,p=0.03),且不适VAS随绝对湿度和温度升高而增加(p<0.01和p=0.007),不适VAS与呼吸困难VAS相关(p=0.001)。动脉血气、呼吸频率、ΔPES、PTPES及ΔPL各条件相似;总异步指数相似,但NoH和HME组自动触发率较低(p=0.03)。作者认为双管路无湿化可实现充分气体调节、优化舒适度并改善人机交互。

要点

  • 在急性低氧性呼吸衰竭患者头盔无创通气中,双管路无湿化(NoH)组不适VAS中位数4分,低于HME组6分、HH34组7分、HH37组8分(p=0.03)。
  • NoH组绝对湿度中位数16 mgH2O/L,低于HME组28、HH34组28、HH37组33 mgH2O/L(p<0.001);温度29°C低于30、31、32°C(p<0.001)。
  • 不适VAS随绝对湿度升高(p<0.01)和温度升高(p=0.007)而增加,且不适VAS越高呼吸困难VAS越高(p=0.001)。
  • 各湿化条件下动脉血气、呼吸频率、ΔPES、PTPES及ΔPL相似;总异步指数相似,但NoH和HME组自动触发率较低(p=0.03)。
  • 作者结论:头盔无创通气1小时期间双管路无湿化可实现充分气体调节、优化舒适度并改善人机交互;使用加热湿化器或热湿交换器因界面内过热过湿增加不适并加重呼吸困难。

适用人群与场景

  • 急性低氧性呼吸衰竭患者,PaO2/FiO2 < 300 mmHg,接受头盔无创通气。

诊断标准与关键阈值

  • 纳入标准:急性低氧性呼吸衰竭,PaO2/FiO2 < 300 mmHg。
  • 头盔无创通气设置:PEEP 12 cmH2O,压力支持12 cmH2O。

处置流程与药物剂量

  • 试验中四种湿化设置按随机顺序各应用1小时:双管路加热湿化器温度设34°C(HH34)和37°C(HH37);Y型管路热湿交换器(HME);双管路无湿化(NoH)。

研究设计与关键结果

  • 研究类型:随机顺序交叉生理学研究,纳入20例急性低氧性呼吸衰竭(PaO2/FiO2 < 300 mmHg)患者,比较头盔无创通气(PEEP 12 cmH2O,压力支持12 cmH2O)下四种湿化设置各1小时。
  • 绝对湿度中位数[IqR]:NoH 16 [12-19] mgH2O/L vs HME 28 [23-31] vs HH34 28 [24-31] vs HH37 33 [29-38],p < 0.001。
  • 温度中位数[IqR]:NoH 29 [28-30]°C vs HME 30 [29-31] vs HH34 31 [29-32] vs HH37 32 [31-33],p < 0.001。
  • 不适VAS中位数[IqR]:NoH 4 [2-6] vs HME 6 [2-7] vs HH34 7 [4-8] vs HH37 8 [4-10],p = 0.03。
  • 不适VAS随绝对湿度升高而增加(p < 0.01),随温度升高而增加(p = 0.007);不适VAS越高与呼吸困难VAS越高相关(p = 0.001)。
  • 动脉血气、呼吸频率、ΔPES、PTPES和ΔPL在所有条件下相似;总异步指数各步骤相似,但自动触发率在NoH和HME组较低(p = 0.03)。
  • 试验注册:clinicaltrials.gov(NCT02875379),注册日期2016年8月23日。

证据类型、等级与局限

  • 证据类型:随机顺序交叉生理学研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为:在急性低氧性呼吸衰竭患者头盔无创通气1小时期间,双管路无湿化可实现充分气体调节、优化舒适度并改善人机交互;使用加热湿化器或热湿交换器因界面内过热过湿增加不适并加重呼吸困难。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: There is growing interest towards the use of helmet noninvasive ventilation (NIV) for the management of acute hypoxemic respiratory failure. Gas conditioning through heat and moisture exchangers (HME) or heated humidifiers (HHs) is needed during facemask NIV to provide a minimum level of humidity in the inspired gas (15 mg H2O/L). The optimal gas conditioning strategy during helmet NIV remains to be established.

METHODS: Twenty patients with acute hypoxemic respiratory failure (PaO2/FiO2 < 300 mmHg) underwent consecutive 1-h periods of helmet NIV (PEEP 12 cmH2O, pressure support 12 cmH2O) with four humidification settings, applied in a random order: double-tube circuit with HHs and temperature set at 34 °C (HH34) and 37 °C (HH37); Y-piece circuit with HME; double-tube circuit with no humidification (NoH). Temperature and humidity of inhaled gas were measured through a capacitive hygrometer. Arterial blood gases, discomfort and dyspnea through visual analog scales (VAS), esophageal pressure swings (ΔPES) and simplified pressure-time product (PTPES), dynamic transpulmonary driving pressure (ΔPL) and asynchrony index were measured in each step.

RESULTS: Median [IqR] absolute humidity, temperature and VAS discomfort were significantly lower during NoH vs. HME, HH34 and HH37: absolute humidity (mgH2O/L) 16 [12-19] vs. 28 [23-31] vs. 28 [24-31] vs. 33 [29-38], p < 0.001; temperature (°C) 29 [28-30] vs. 30 [29-31] vs. 31 [29-32] vs 32. [31-33], p < 0.001; VAS discomfort 4 [2-6] vs. 6 [2-7] vs. 7 [4-8] vs. 8 [4-10], p = 0.03. VAS discomfort increased with higher absolute humidity (p < 0.01) and temperature (p = 0.007). Higher VAS discomfort was associated with increased VAS dyspnea (p = 0.001). Arterial blood gases, respiratory rate, ΔPES, PTPES and ΔPL were similar in all conditions. Overall asynchrony index was similar in all steps, but autotriggering rate was lower during NoH and HME (p = 0.03).

CONCLUSIONS: During 1-h sessions of helmet NIV in patients with hypoxemic respiratory failure, a double-tube circuit with no humidification allowed adequate conditioning of inspired gas, optimized comfort and improved patient-ventilator interaction. Use of HHs or HME in this setting resulted in increased discomfort due to excessive heat and humidity in the interface, which was associated with more intense dyspnea. Trail Registration Registered on clinicaltrials.gov (NCT02875379) on August 23rd, 2016.

来源:Ann Intensive Care,查看原文。版权归原作者所有。

参考来源

  1. Bongiovanni F, Grieco DL, Anzellotti GM, et al. Gas conditioning during helmet noninvasive ventilation: effect on comfort, gas exchange, inspiratory effort, transpulmonary pressure and patient-ventilator interaction. Ann Intensive Care. 2021. PMID: 34952962. doi:10.1186/s13613-021-00972-9

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。