文献速递呼吸衰竭与机械通气重症综合管理与镇静镇痛

肺保护性通气中反向触发异步对膈肌功能的影响:实验模型

Impact of Reverse Triggering Dyssynchrony during Lung-Protective Ventilation on Diaphragm Function: An Experimental Model.
PubMed 文献 · Am J Respir Crit Care Med · 2022-01-01
一句话结论动物实验显示:肺保护性通气中高呼吸努力的反向触发异步与膈肌功能受损相关,低努力则保留膈肌力。

研究用32头猪经表面活性物质耗竭和高应力通气诱导肺损伤,分为被动机械通气组(潮气量10 ml/kg,呼吸频率30-35次/分,n=8)和更肺保护性策略组(潮气量6-8 ml/kg,n=24,调整呼吸频率促进反向触发异步)通气3小时。比较被动通气,出现反向触发异步的保护性通气组潮气量更低(7 vs. 10 ml/kg)、呼吸频率更高(45 vs. 31次/分)。1:1同步模式在83%的动物中最常见,反向触发异步引起的呼吸努力在动物间变异大。最低三分位呼吸努力的反向触发异步与被动通气相比,单次刺激膈肌压(twitch Pdi)高23%;高呼吸努力的反向触发异步则与twitch Pdi低10%及异常肌纤维比例增高相关。结论:高努力的反向触发异步与膈肌功能受损相关,低努力则膈肌力保留。

要点

  • 在肺损伤猪模型中,更肺保护性通气(潮气量6-8 ml/kg)出现反向触发异步时,潮气量7 vs. 10 ml/kg、呼吸频率45 vs. 31次/分,均较被动通气组显著更低/更高。
  • 1:1同步模式在83%的动物中最常见,反向触发异步引起的呼吸努力在动物间变异大。
  • 最低三分位呼吸努力的反向触发异步与被动通气相比,单次刺激膈肌压(twitch Pdi)高23%。
  • 高呼吸努力的反向触发异步与被动通气相比,twitch Pdi低10%,且异常肌纤维比例更高。

适用人群与场景

  • 表面活性物质耗竭和高应力通气诱导肺损伤的32头机械通气猪。
  • 被动机械通气组:潮气量10 ml/kg,呼吸频率30-35次/分,n=8。
  • 更肺保护性策略组:潮气量6-8 ml/kg,调整呼吸频率促进反向触发异步,n=24,通气3小时。

研究设计与关键结果

  • 研究类型:动物实验模型;32头肺损伤猪。
  • 被动通气组(n=8)潮气量10 ml/kg、呼吸频率30-35次/分;更肺保护性策略组(n=24)潮气量6-8 ml/kg,调整呼吸频率促进反向触发异步,通气3小时。
  • 出现反向触发异步的保护性通气组较被动通气组潮气量更低(7 vs. 10 ml/kg)、呼吸频率更高(45 vs. 31次/分)。
  • 1:1同步模式在83%的动物中最常见;反向触发异步引起的呼吸努力在动物间变异大。
  • 最低三分位呼吸努力的反向触发异步与被动通气相比,单次刺激膈肌压(twitch Pdi)高23%。
  • 高呼吸努力的反向触发异步与被动通气相比,单次刺激膈肌压(twitch Pdi)低10%,异常肌纤维比例更高。

证据类型、等级与局限

  • 证据类型:动物实验模型。
  • 局限:原文未报告局限性。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「对床旁实践的改变」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

Rationale: Reverse triggering dyssynchrony (RT) is a patient-ventilator interaction where a respiratory muscle contraction is triggered by a passive mechanical insufflation. Its impact on diaphragm structure and function is unknown. Objectives: To establish an animal model of RT with lung injury receiving lung-protective ventilation and to assess its impact on the structure and function of the diaphragm. Methods: Lung injury was induced by surfactant depletion and high-stress ventilation in 32 ventilated pigs. Animals were allocated to receive passive mechanical ventilation (Vt: 10 ml/kg; respiratory rate [RR]: 30-35 breaths/min; n = 8) or a more lung-protective strategy (Vt: 6-8 ml/kg; n = 24) with adjustments in RR to facilitate the occurrence of RT for 3 hours. Diaphragm function (transdiaphragmatic pressure [Pdi] during phrenic nerve stimulation [force/frequency curve]) and structure (biopsies) were assessed. The impact of RT on diaphragm function was analyzed according to the breathing effort assessed by the pressure-time product. Measurements and Main Results: Compared with passive ventilation, the protective ventilation group with RT received significantly lower Vt (7 vs. 10 ml/kg) and higher RR (45 vs. 31 breaths/min). An entrainment pattern of 1:1 was the most frequently occurring in 83% of the animals. Breathing effort induced by RT was highly variable across animals. RT with the lowest tercile of breathing effort was associated with 23% higher twitch Pdi compared with passive ventilation, whereas RT with high breathing effort was associated with a 10% lower twitch Pdi and a higher proportion of abnormal muscle fibers. Conclusions: In a reproducible animal model of RT with variable levels of breathing effort and entrainment patterns, RT with high effort is associated with impaired diaphragm function, whereas RT with low effort is associated with preserved diaphragm force.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

参考来源

  1. Damiani LF, Engelberts D, Bastia L, et al. Impact of Reverse Triggering Dyssynchrony during Lung-Protective Ventilation on Diaphragm Function: An Experimental Model. Am J Respir Crit Care Med. 2022. PMID: 34941477. doi:10.1164/rccm.202105-1089OC

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。