文献速递心脑血管急症重症综合管理与镇静镇痛

短暂低灌注至缺血/缺氧性扩散去极化与大鼠大脑皮层自动调节衰竭相关

Transient Hypoperfusion to Ischemic/Anoxic Spreading Depolarization is Related to Autoregulatory Failure in the Rat Cerebral Cortex.
PubMed 文献 · Neurocrit Care · 2021-12-02
一句话结论大鼠研究提示:短暂低血压合并脑血管自动调节功能衰竭可能先于扩散去极化发生,并构成其发生的实质性风险。

研究在异氟烷麻醉大鼠中通过双侧颈总动脉闭塞制造不完全全脑缺血,诱导缺血性扩散去极化(iSD),20–40分钟后通过短暂缺氧(撤氧4–5分钟)诱导缺氧性扩散去极化(aSD),用皮层微电极记录直流电位和细胞外K+浓度,激光多普勒血流仪测局部脑血流,股动脉导管测平均动脉压并计算脑血管自动调节指数rCBFx。iSD和aSD均伴脑血流短暂下降(分别降至11.9±2.9%和7.4±3.6%),但iSD时rCBFx<0.3提示自动调节完整,aSD时rCBFx>0.3提示自动调节衰竭、脑血流随平均动脉压下降。iSD后15–20秒脑血流下降,而aSD前低灌注提前近3分钟出现。作者提出自动调节功能障碍与短暂低血压同时发生构成扩散去极化发生的实质性风险,而非扩散去极化的后果。

要点

  • 大鼠不完全全脑缺血模型中,iSD和aSD均伴脑血流短暂下降,分别降至11.9±2.9%和7.4±3.6%。
  • iSD时rCBFx<0.3提示自动调节完整;aSD时rCBFx>0.3提示自动调节衰竭,脑血流随平均动脉压下降。
  • iSD后15–20秒脑血流下降,而aSD前低灌注提前近3分钟出现。
  • 作者提出自动调节功能障碍与短暂低血压同时发生构成扩散去极化发生的实质性风险,而非扩散去极化的后果。

适用人群与场景

  • 异氟烷麻醉大鼠,行双侧颈总动脉闭塞造成不完全全脑缺血。

诊断标准与关键阈值

  • 通过皮层内微电极记录直流电位和细胞外K+浓度确认扩散去极化发生。
  • rCBFx<0.3提示自动调节完整,rCBFx>0.3提示自动调节衰竭。

研究设计与关键结果

  • 研究类型:大鼠实验研究;样本量原文未报告;人群:异氟烷麻醉大鼠不完全全脑缺血模型;干预:双侧颈总动脉闭塞诱导iSD,20–40分钟后撤氧4–5分钟诱导aSD;对照:无。
  • iSD和aSD均伴脑血流短暂下降,分别降至11.9±2.9%和7.4±3.6%。
  • iSD时rCBFx<0.3提示自动调节完整;aSD时rCBFx>0.3提示自动调节衰竭,脑血流随平均动脉压下降。
  • iSD后15–20秒脑血流下降,而aSD前低灌注提前近3分钟出现。
  • iSD的脑血流反应表现为典型扩散性缺血特征;aSD的短暂脑血流下降似乎是缺氧相关低血压后脑血流的被动下降,导致aSD。

证据类型、等级与局限

  • 证据类型:动物实验研究;局限:原文未报告局限性。

对床旁实践的改变

  • 作者提出,与短暂低血压同时发生的脑血管自动调节功能障碍构成扩散去极化发生的实质性风险,且不是扩散去极化的后果。
  • 作者指出,在此情况下发生的扩散去极化不伴可识别的脑血流反应,提示神经血管耦合严重受损。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: In ischemic stroke, cerebral autoregulation and neurovascular coupling may become impaired. The cerebral blood flow (CBF) response to spreading depolarization (SD) is governed by neurovascular coupling. SDs recur in the ischemic penumbra and reduce neuronal viability by the insufficiency of the CBF response. Autoregulatory failure and SD may coexist in acute brain injury. Here, we set out to explore the interplay between the impairment of cerebrovascular autoregulation, SD occurrence, and the evolution of the SD-coupled CBF response.

METHODS: Incomplete global forebrain ischemia was created by bilateral common carotid artery occlusion in isoflurane-anesthetized rats, which induced ischemic SD (iSD). A subsequent SD was initiated 20-40 min later by transient anoxia SD (aSD), achieved by the withdrawal of oxygen from the anesthetic gas mixture for 4-5 min. SD occurrence was confirmed by the recording of direct current potential together with extracellular K+ concentration by intracortical microelectrodes. Changes in local CBF were acquired with laser Doppler flowmetry. Mean arterial blood pressure (MABP) was continuously measured via a catheter inserted into the left femoral artery. CBF and MABP were used to calculate an index of cerebrovascular autoregulation (rCBFx). In a representative imaging experiment, variation in transmembrane potential was visualized with a voltage-sensitive dye in the exposed parietal cortex, and CBF maps were generated with laser speckle contrast analysis.

RESULTS: Ischemia induction and anoxia onset gave rise to iSD and aSD, respectively, albeit aSD occurred at a longer latency, and was superimposed on a gradual elevation of K+ concentration. iSD and aSD were accompanied by a transient drop of CBF (down to 11.9 ± 2.9 and 7.4 ± 3.6%, iSD and aSD), but distinctive features set the hypoperfusion transients apart. During iSD, rCBFx indicated intact autoregulation (rCBFx < 0.3). In contrast, aSD was superimposed on autoregulatory failure (rCBFx > 0.3) because CBF followed the decreasing MABP. CBF dropped 15-20 s after iSD, but the onset of hypoperfusion preceded aSD by almost 3 min. Taken together, the CBF response to iSD displayed typical features of spreading ischemia, whereas the transient CBF reduction with aSD appeared to be a passive decrease of CBF following the anoxia-related hypotension, leading to aSD.

CONCLUSIONS: We propose that the dysfunction of cerebrovascular autoregulation that occurs simultaneously with hypotension transients poses a substantial risk of SD occurrence and is not a consequence of SD. Under such circumstances, the evolving SD is not accompanied by any recognizable CBF response, which indicates a severely damaged neurovascular coupling.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Menyhárt Á, Varga DP, M Tóth O, et al. Transient Hypoperfusion to Ischemic/Anoxic Spreading Depolarization is Related to Autoregulatory Failure in the Rat Cerebral Cortex. Neurocrit Care. 2021. PMID: 34855119. doi:10.1007/s12028-021-01393-z

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。