内科重症监护病房与急诊科脓毒症监测及决策支持的实施与评估
该单中心前后对照研究评估了基于电子病历的脓毒症监测系统联合临床决策支持和完成反馈在MICU与ED的实施效果。共纳入1950例严重脓毒症或脓毒性休克患者,实施前854例、实施后1096例,基线特征相似。警报性能中等:敏感性79.9%、特异性76.9%、阳性预测值27.9%、阴性预测值97.2%。在考虑干预前依从性已呈改善趋势后,干预与集束化治疗依从性改善无关联(OR 1.16,95%CI 0.71-1.89,P=0.554),与住院死亡率改善也无关联(OR 1.55,95%CI 0.95-2.52,P=0.078)。
要点
- 脓毒症监测警报性能中等:敏感性79.9%、特异性76.9%、阳性预测值27.9%、阴性预测值97.2%。
- 实施监测系统后共产生3424条独立警报,确认脓毒症患者1131例。
- 考虑干预前依从性改善趋势后,干预与集束化治疗依从性改善无关联(OR 1.16,95%CI 0.71-1.89,P=0.554)。
- 干预与住院死亡率改善无关联(OR 1.55,95%CI 0.95-2.52,P=0.078)。
- 作者结论认为,包含决策支持或完成反馈的脓毒症监测系统与脓毒症诊治及患者结局改善无关联。
适用人群与场景
- 2011年9月4日至2018年5月1日入住***医院MICU和ED的18岁及以上严重脓毒症或脓毒性休克患者。
研究设计与关键结果
- 研究类型:单中心前后对照研究;场景:大型学术中心MICU和ED;共纳入1950例MICU严重脓毒症或脓毒性休克患者,实施前854例、实施后1096例,基线特征相似。
- 干预:基于电子病历的脓毒症监测系统,辅以临床决策支持和完成反馈。
- 警报性能:敏感性79.9%、特异性76.9%、阳性预测值27.9%、阴性预测值97.2%;实施后共3424条独立警报,确认脓毒症患者1131例。
- 主要结局:考虑干预前依从性改善趋势后,干预与集束化治疗依从性改善无关联(OR 1.16,95%CI 0.71-1.89,P=0.554)。
- 次要结局:干预与住院死亡率改善无关联(OR 1.55,95%CI 0.95-2.52,P=0.078)。
证据类型、等级与局限
- 证据类型:单中心前后对照研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者结论认为,包含决策支持或完成反馈的脓毒症监测系统与脓毒症诊治及患者结局改善无关联。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
OBJECTIVE: To improve the timely diagnosis and treatment of sepsis many institutions implemented automated sepsis alerts. Poor specificity, time delays, and a lack of actionable information lead to limited adoption by bedside clinicians and no change in practice or clinical outcomes. We aimed to compare sepsis care compliance before and after a multi-year implementation of a sepsis surveillance coupled with decision support in a tertiary care center.
DESIGN: Single center before and after study.
SETTING: Large academic Medical Intensive Care Unit (MICU) and Emergency Department (ED).
POPULATION: Patients 18 years of age or older admitted to *** Hospital MICU and ED from 09/4/2011 to 05/01/2018 with severe sepsis or septic shock.
INTERVENTIONS: Electronic medical record-based sepsis surveillance system augmented by clinical decision support and completion feedback.
MEASUREMENTS AND MAIN RESULTS: There were 1950 patients admitted to the MICU with the diagnosis of severe sepsis or septic shock during the study period. The baseline characteristics were similar before (N = 854) and after (N = 1096) implementation of sepsis surveillance. The performance of the alert was modest with a sensitivity of 79.9%, specificity of 76.9%, positive predictive value (PPV) 27.9%, and negative predictive value (NPV) 97.2%. There were 3424 unique alerts and 1131 confirmed sepsis patients after the sniffer implementation. During the study period average care bundle compliance was higher; however after taking into account improvements in compliance leading up to the intervention, there was no association between intervention and improved care bundle compliance (Odds ratio: 1.16; 95% CI: 0.71 to 1.89; p-value 0.554). Similarly, the intervention was not associated with improvement in hospital mortality (Odds ratio: 1.55; 95% CI: 0.95 to 2.52; p-value: 0.078).
CONCLUSIONS: A sepsis surveillance system incorporating decision support or completion feedback was not associated with improved sepsis care and patient outcomes.
参考来源
- Lipatov K, Daniels CE, Park JG, et al. Implementation and evaluation of sepsis surveillance and decision support in medical ICU and emergency department. Am J Emerg Med. 2021. PMID: 34823194. doi:10.1016/j.ajem.2021.09.086
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。