指南与共识呼吸衰竭与机械通气儿科与产科急症

基于共识算法的记录血氧监测与多导睡眠图在早产儿停止家庭氧疗中的比较

Does recorded oximetry utilizing a consensus-based algorithm compare to polysomnography in discontinuing home oxygen therapy in premature infants?
指南 / 共识 · Pediatr Pulmonol · 2021-12-12
一句话结论在无其他睡眠呼吸障碍风险的支气管肺发育不良早产儿中,记录家庭血氧监测与多导睡眠图在判断停止家庭氧疗上结果一致率96%,可安全有效替代多导睡眠图。

约三分之一的极早产儿诊断支气管肺发育不良后需要家庭氧疗,美国门诊管理因缺乏共识指南而差异显著,停止氧疗前常行多导睡眠图评估,但多导睡眠图因费用、可及性和父母压力而不理想。本研究为RHO试验的队列分析,比较夜间记录家庭血氧监测与多导睡眠图数据,纳入同时或24小时内完成两种记录的患儿。53例随机接受多导睡眠图的患儿中55%完成多导睡眠图,其中32例(64%)完成两种记录比较。Bland-Altman分析显示血氧饱和度低于90%的时间在两种方法间高度一致(斜率=1.014,p=0.24),96%的病例结果一致。作者认为,对于无其他睡眠呼吸障碍风险的支气管肺发育不良患儿,记录家庭血氧监测是安全有效的替代多导睡眠图的方法,有助于确定停止家庭氧疗的时机。

要点

  • 在无其他睡眠呼吸障碍风险的支气管肺发育不良早产儿中,记录家庭血氧监测与多导睡眠图判断停止家庭氧疗的结果一致率达96%。
  • Bland-Altman分析显示两种方法测得的血氧饱和度低于90%的时间高度一致(斜率=1.014,p=0.24)。
  • RHO试验中随机接受多导睡眠图的53例患儿仅55%完成多导睡眠图,其中64%(32例)完成两种记录比较。
  • 两种记录组中白人婴儿均多于其他种族和族裔。
  • 记录家庭血氧监测可作为多导睡眠图的替代方法,用于无其他睡眠呼吸障碍风险的支气管肺发育不良患儿停止家庭氧疗的评估。

适用人群与场景

  • 来自RHO试验的极早产儿,诊断为支气管肺发育不良并需要家庭氧疗,且无其他睡眠呼吸障碍风险。

研究设计与关键结果

  • 研究类型:RHO试验的队列分析,RHO试验为随机、非盲、多中心试验,比较两种氧疗管理策略。
  • 样本量:53例随机接受多导睡眠图的患儿中55%完成多导睡眠图,其中32例(64%)完成多导睡眠图与记录家庭血氧监测的比较。
  • 主要结果:Bland-Altman分析显示血氧饱和度低于90%的时间在两种方法间高度一致(斜率=1.014,p=0.24),96%的病例结果一致。
  • 非血氧测定发现:多导睡眠图中改变临床管理的非血氧测定发现被识别。
  • 人群特征:两种记录组中白人婴儿均多于其他种族和族裔。

证据类型、等级与局限

  • 证据类型:随机、非盲、多中心试验的队列分析。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,对于无其他睡眠呼吸障碍风险的支气管肺发育不良婴儿,记录家庭血氧监测是安全有效的替代多导睡眠图的方法,可辅助确定停止家庭氧疗。

指南或共识出处

  • Pediatr Pulmonol

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: Approximately a third of all extremely preterm infants diagnosed with bronchopulmonary dysplasia will require home oxygen therapy (HOT). Lack of consensus-based guidelines has led to significant variability in outpatient HOT management in the United States. A common assessment performed before discontinuing oxygen is a formal polysomnogram (PSG). PSGs are potentially undesirable due to cost, lack of convenient access, and parental stress, so alternative testing to determine the optimal timing of safe oxygen discontinuation are needed.

METHODS: We compared nocturnal recorded home oximetry (RHO) with PSG data in a cohort of patients from the RHO trial for patients who had recordings performed simultaneously to or within 24 h of their PSG. The RHO trial was a randomized, unblinded, multi-center trial comparing two oxygen management strategies. Parameters of oxygenation were compared between PSG and RHO, and nonoximegtry findings from the PSG that changed clinical management were identified.

RESULTS: A total of 53 infants randomized to obtain a PSG as part of the RHO trial (55%) completed a PSG, and of those, 32 (64%) completed both a PSG with comparison RHO. There were more white infants in both groups than other races and ethnicities. Bland-Altman analysis showed a strong agreement of oxygen saturation time below 90% SpO2 between PSG and RHO results (slope = 1.014, p = 0.24). Results agreed in 96% of cases.

CONCLUSION: RHO is a safe and effective alternative to PSG to assist in determination of discontinuing HOT in infants with BPD without other risks for sleep-disordered breathing.

来源:Pediatr Pulmonol,查看原文。版权归原作者所有。

参考来源

  1. White H, Sobelman C, Kremer T, et al. Does recorded oximetry utilizing a consensus-based algorithm compare to polysomnography in discontinuing home oxygen therapy in premature infants? Pediatr Pulmonol. 2021. PMID: 34811971. doi:10.1002/ppul.25770

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。