文献速递心脑血管急症重症综合管理与镇静镇痛

基于定量脑电图的超难治性癫痫持续状态发作评估

Quantitative EEG-Based Seizure Estimation in Super-Refractory Status Epilepticus.
PubMed 文献 · Neurocrit Care · 2021-11-17
一句话结论在超难治性癫痫持续状态患者中,qEEG专家与新手对发作检测均敏感度高但特异度低,qEEG专家估计的发作负荷与金标准无差异。

本研究回顾2009—2019年69例超难治性癫痫持续状态(SRSE)患者的脑电记录,由三组判读者标注发作:仅用原始脑电的神经电生理专家(金标准)、有丰富qEEG分析经验的神经重症医师(qEEG专家)和仅用qEEG趋势面板的无经验判读者(qEEG新手)。原始脑电专家识别出35例(51%)患者有发作,共2950次发作(3126分钟)。qEEG专家敏感度93%、特异度61%、假阳性率每天6.5次,两名qEEG专家间一致性良好(κ=0.64);qEEG新手敏感度98.5%、特异度13%、假阳性率每天15次,一致性一般(κ=0.4)。qEEG专家估计的发作负荷与金标准无差异(3257分钟 vs 3126分钟),而qEEG新手报告更高负荷(6066分钟 vs 3126分钟)。

要点

  • qEEG专家检测SRSE发作的敏感度93%、特异度61%、假阳性率每天6.5次,两名专家间一致性κ=0.64(良好)。
  • qEEG新手检测SRSE发作的敏感度98.5%、特异度13%、假阳性率每天15次,两名新手间一致性κ=0.4(一般)。
  • qEEG专家估计的发作负荷与原始脑电金标准无差异:3257分钟 vs 3126分钟。
  • qEEG新手报告的发作负荷高于金标准:6066分钟 vs 3126分钟。
  • 原始脑电专家在69例SRSE中识别出35例(51%)有发作,共2950次发作、3126分钟。

适用人群与场景

  • 2009—2019年期间69例超难治性癫痫持续状态(SRSE)患者的脑电记录。

研究设计与关键结果

  • 研究类型:脑电记录判读准确性研究;样本量69例SRSE患者,脑电记录来自2009—2019年。
  • 金标准:两名神经电生理专家仅用原始脑电判读,识别出35例(51%)患者有发作,共2950次发作(3126分钟)。
  • qEEG专家(两名有丰富qEEG分析经验的神经重症医师,仅用qEEG趋势面板):敏感度93%、特异度61%、假阳性率每天6.5次,两名专家间一致性κ=0.64。
  • qEEG新手(两名无经验判读者,仅用qEEG趋势面板):敏感度98.5%、特异度13%、假阳性率每天15次,两名新手间一致性κ=0.4。
  • 发作负荷:qEEG专家与金标准无差异(3257分钟 vs 3126分钟);qEEG新手报告高于金标准(6066分钟 vs 3126分钟)。

证据类型、等级与局限

  • 证据类型:脑电记录判读准确性研究。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,qEEG可作为qEEG专家估计SRSE患者发作负荷的有用工具。
  • qEEG专家与新手对SRSE发作检测均敏感度高但特异度低。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

BACKGROUND: The objective of this study was to evaluate the accuracy of seizure burden in patients with super-refractory status epilepticus (SRSE) by using quantitative electroencephalography (qEEG).

METHODS: EEG recordings from 69 patients with SRSE (2009-2019) were reviewed and annotated for seizures by three groups of reviewers: two board-certified neurophysiologists using only raw EEG (gold standard), two neurocritical care providers with substantial experience in qEEG analysis (qEEG experts), and two inexperienced qEEG readers (qEEG novices) using only a qEEG trend panel.

RESULTS: Raw EEG experts identified 35 (51%) patients with seizures, accounting for 2950 seizures (3,126 min). qEEG experts had a sensitivity of 93%, a specificity of 61%, a false positive rate of 6.5 per day, and good agreement (κ = 0.64) between both qEEG experts. qEEG novices had a sensitivity of 98.5%, a specificity of 13%, a false positive rate of 15 per day, and fair agreement (κ = 0.4) between both qEEG novices. Seizure burden was not different between the qEEG experts and the gold standard (3,257 vs. 3,126 min), whereas qEEG novices reported higher burden (6066 vs. 3126 min).

CONCLUSIONS: Both qEEG experts and novices had a high sensitivity but a low specificity for seizure detection in patients with SRSE. qEEG could be a useful tool for qEEG experts to estimate seizure burden in patients with SRSE.

来源:Neurocrit Care,查看原文。版权归原作者所有。

参考来源

  1. Alkhachroum A, Ganesan SL, Koren JP, et al. Quantitative EEG-Based Seizure Estimation in Super-Refractory Status Epilepticus. Neurocrit Care. 2021. PMID: 34791594. doi:10.1007/s12028-021-01395-x

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。