文献速递复苏、休克与脓毒症心脑血管急症

心肺复苏中更快实现头胸部自动抬高可提高自主循环恢复概率

Faster time to automated elevation of the head and thorax during cardiopulmonary resuscitation increases the probability of return of spontaneous circulation.
PubMed 文献 · Resuscitation · 2021-11-15
一句话结论院外心脏骤停后,从9-1-1呼叫至自动头高位(AHUP)装置放置时间越短,ROSC概率越高,可除颤心律每延迟1分钟ROSC概率下降9.0%。

该研究基于患者登记数据的观察性分析,评估院外心脏骤停后从9-1-1呼叫至AHUP装置放置时间对ROSC的影响。患者接受主动按压减压和/或自动CPR、阻抗阈值装置及AHUP装置治疗。6个站点共227例患者,总ROSC概率34%(77/227),可除颤心律47%(18/38)。各站点间9-1-1至AHUP装置时间及ROSC概率均存在显著差异(p=0.0001和p=0.019)。所有心律在4-12分钟内每延迟1分钟ROSC概率下降5.6%(p=0.024),可除颤心律在6-15分钟内每延迟1分钟下降9.0%(p=0.006)。结论认为更快部署AHUP方案与更高ROSC发生率相关,在评估和实施该方案时需考虑此因素。

要点

  • 总ROSC概率为34%(77/227),可除颤心律ROSC概率为47%(18/38)。
  • 各站点从9-1-1呼叫至AHUP装置放置的中位时间(范围)从6.4(4,15)分钟到19.0(8,38)分钟不等,站点间差异显著(p=0.0001)。
  • 各站点ROSC概率从22.7%(17/75)到60%(3/5)不等,站点间差异显著(p=0.019)。
  • 所有心律在4-12分钟内(n=85),每延迟1分钟ROSC概率下降5.6%(p=0.024)。
  • 可除颤心律在6-15分钟内(n=23),每延迟1分钟ROSC概率下降9.0%(p=0.006)。

适用人群与场景

  • 院外心脏骤停患者,接受主动按压减压和/或自动心肺复苏、阻抗阈值装置及自动头高位装置治疗。

研究设计与关键结果

  • 研究类型为基于患者登记数据的观察性分析,共11个站点,其中6个站点记录了从9-1-1呼叫至AHUP装置放置的时间(n=227)。
  • 所有心律ROSC概率为34%(77/227),可除颤心律ROSC概率为47%(18/38)。
  • 患者中位年龄66岁(范围19-101岁),男性占68%。
  • 各站点从9-1-1呼叫至AHUP装置放置的中位时间(范围)分别为:1)6.4(4,15)分钟,2)8.0(5,19)分钟,3)9.9(4,12)分钟,4)14.1(6,36)分钟,5)15.9(6,34)分钟,6)19.0(8,38)分钟(p=0.0001)。
  • 各站点ROSC概率分别为:1)55.1%(16/29),2)60%(3/5),3)50%(3/6),4)22.7%(17/75),5)26.4%(9/34),6)37.1%(29/78)(p=0.019)。
  • 所有心律在4-12分钟内(n=85),每延迟1分钟ROSC概率下降5.6%(p=0.024)。
  • 可除颤心律在6-15分钟内(n=23),每延迟1分钟ROSC概率下降9.0%(p=0.006)。

证据类型、等级与局限

  • 证据类型:观察性研究(基于患者登记数据的分析)。
  • 局限:原文未报告局限性。

对床旁实践的改变

  • 作者认为,更快部署基于AHUP的方案与更高的ROSC发生率相关,在评估和实施该方案时必须考虑这一因素。

提炼说明

  • 本条依据论文摘要整理;摘要未涉及「诊断标准与关键阈值」「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开

OBJECTIVES: Resuscitation in the Head Up position improves outcomes in animals treated with active compression decompression cardiopulmonary resuscitation and an impedance threshold device (ACD + ITD CPR).We assessed impact of time to deployment of an automated Head Up position (AHUP) based bundle of care after out-of-hospital cardiac arrest on return of spontaneous circulation (ROSC).

METHODS: Observational data were analyzed from a patient registry. Patients received treatment with 1) ACD + and/or automated CPR 2) an ITD and 3) an AHUP device. Probability of ROSC (ROSCprob) from the 9-1-1 call to AHUP device placement was assessed with a restricted cubic spline model and linear regression.

RESULTS: Of 11 sites, 6 recorded the interval from 9-1-1 to AHUP device (n = 227). ROSCprobfor all rhythms was 34%(77/227). Median age (range) was 66 years (19-101) and 68% men. TheROSCprobfor shockable rhythms was 47%(18/38). Minutes from 9-1-1 to AHUP device (median, range) varied between sites: 1) 6.4(4,15), 2) 8.0(5,19), 3) 9.9(4, 12), 4) 14.1(6, 36), 5) 15.9(6, 34), 6) 19.0(8, 38),(p = 0.0001).ROSCprobalso varied; 1) 55.1%(16/29), 2) 60%(3/5), 3) 50%(3/6), 4) 22.7%(17/75), 5) 26.4%(9/34), and 6) 37.1%(29/78), (p = 0.019). For all rhythms between 4 and 12 min (n = 85),ROSCprobdeclined 5.6% for every minute elapsed (p = 0.024). For shockable rhythms, between 6 and 15 min (n = 23),ROSCprobdeclined 9.0% for every minute elapsed (p = 0.006).

CONCLUSIONS: Faster time to deployment of an AHUP based bundle of care is associated with higher incidence of ROSC. This must be considered when evaluating and implementing this bundle.

来源:Resuscitation,查看原文。版权归原作者所有。

参考来源

  1. Moore JC, Duval S, Lick C, et al. Faster time to automated elevation of the head and thorax during cardiopulmonary resuscitation increases the probability of return of spontaneous circulation. Resuscitation. 2021. PMID: 34793874. doi:10.1016/j.resuscitation.2021.11.008

供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。