自动体外除颤器取用距离越长,院外心脏骤停后生存率越低
该研究纳入2014至2018年丹麦南部地区使用AED的院外心脏骤停423例,按人口密度分为密集、中等和稀疏区,评估AED取用距离与30天生存的关系。结果显示三区30天生存率分别为40%、31%和34%,差异无统计学意义(P=0.3);AED取用距离中位数分别为105米、220米和350米(P<0.001);多因素回归分析显示,AED每远离事发地点100米,死亡率增加10%。作者认为,使用AED的院外心脏骤停生存率在三种人口密度区似乎无差异,但取用距离与生存率降低相关。
要点
- 多因素回归分析显示,AED取用距离每增加100米,死亡率增加10%。
- 密集区(≥200人/km²)30天生存率40%,中等区(20-199人/km²)31%,稀疏区(0-19人/km²)34%,三组差异无统计学意义(P=0.3)。
- AED取用距离中位数:密集区105米(IQR 5-450),中等区220米(IQR 5-450),稀疏区350米(IQR 5-1500)(P<0.001)。
- 研究纳入423例使用AED的院外心脏骤停,排除养老院发生的病例。
适用人群与场景
- 2014至2018年丹麦南部地区发生并使用AED的院外心脏骤停患者,且心脏骤停地址已知。
- 排除养老院发生的院外心脏骤停。
诊断标准与关键阈值
- 人口密度按1000×1000米网格单元内居民数划分:密集区为每km²≥200人,中等区为每km²20-199人,稀疏区为每km²0-19人。
研究设计与关键结果
- 研究纳入423例院外心脏骤停,其中密集区207例(49%),中等区78例(18%),稀疏区138例(33%)。
- AED取用距离中位数:密集区105米(IQR 5-450),中等区220米(IQR 5-450),稀疏区350米(IQR 5-1500)(P<0.001)。
- 30天生存率:密集区40%,中等区31%,稀疏区34%(P=0.3)。
- 多因素回归分析中,AED每远离事发地点100米,死亡率增加10%。
证据类型、等级与局限
- 证据类型:基于丹麦南部地区AED使用系统收集的观察性研究。
- 局限:原文未报告局限性。
对床旁实践的改变
- 作者认为,使用AED的院外心脏骤停生存率在稀疏、中等和密集人口密度区似乎无差异。
- 作者认为,在调整其他潜在解释变量后,AED取用距离长度与生存率降低相关。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「处置流程与药物剂量」「红旗征与不能漏的情况」「指南或共识出处」,故未列出这些栏目;全文请点「阅读原文」。
英文原文(摘要)· 点击展开
AIMS: To evaluate and compare survival after out-of-hospital (OHCA), where an automated external defibrillator (AED) was used, in densely, moderately and thinly populated areas. Also, to evaluate the association between AED retrieval distance and survival after OHCA.
METHODS: From 2014 to 2018, AEDs used during OHCA in the region of Southern Denmark were systematically collected. OHCAs were included if the OHCA address was known. OHCAs at nursing homes were excluded. To evaluate population density, a map with 1000 × 1000 meter grid cells was used with each cell color-graded according to the number of inhabitants. Densely, moderately and thinly populated areas were defined as ≥200 inhabitants, 20-199 inhabitants and 0-19 inhabitants per km2, respectively. Primary outcome was 30-day survival.
RESULTS: A total of 423 cases of OHCA were included, of which 207 (49%) occurred in densely populated areas, while 78 (18%) and 138 (33%) occurred in moderately and thinly populated areas, respectively. AED retrieval distances were: densely populated 105 m (IQR 5-450), moderately populated 220 m (IQR 5-450) and thinly populated 350 m (IQR 5-1500) (P < 0.001). Thirty-day survival was 40%, 31% and 34%, respectively (P = 0.3). In a multivariable regression analysis, mortality increased with 10% per 100 m an AED was placed further away from the site of OHCA.
CONCLUSION: Survival after OHCA, where an AED was used, did not seem to differ in thinly, moderately and densely populated areas. The length of the AED retrieval distance, however, was correlated with reduced survival after adjusting for other potentially explanatory variables.
参考来源
- Sarkisian L, Mickley H, Schakow H, et al. Longer retrieval distances to the automated external defibrillator reduces survival after out-of-hospital cardiac arrest. Resuscitation. 2021. PMID: 34767901. doi:10.1016/j.resuscitation.2021.11.001
供执业医师抢救与诊疗参考,不替代临床判断;剂量请结合体重、肝肾功能和本院药品规格复核,以指南原文为准。