文献速递哮喘

纸质与电子审计反馈对哮喘处方优化的集群随机试验

Comparing paper Letters in addition to Emailed Audit and feedback in Refining Asthma treatment to Improve clinical and environmental Results in primary care through a cluster randomised controlled trial: the CLEAR AIR study
RSS 订阅 · BMJ Open Respiratory Research

CLEAR AIR研究在英国西约克郡273家基层诊所开展集群随机对照试验,比较电子加纸质反馈与仅电子反馈对哮喘处方的影响。主要结局为高碳足迹压力定量吸入装置中预防性吸入剂处方比例,两组无显著差异(干预组-0.15%,对照组-0.19%,风险比1.00,95%CI 0.98至1.03),次要结局亦无差异。

要点

  • 电子加纸质反馈较仅电子反馈未改善哮喘预防性吸入剂处方比例。
  • 两组主要结局变化均很小,风险比1.00(95%CI 0.98至1.03)。
  • 在现有质量改进项目中嵌入实用随机试验具有可行性。

核心结论

  • 无证据表明电子加纸质反馈比仅电子反馈更有效促进更安全、更绿色的哮喘处方。
  • 两种反馈方式下均观察到混合改善的背景趋势。
  • 影响预防性吸入剂处方及向低碳吸入装置转换的障碍仍待明确。

研究设计与样本

  • 平行集群随机对照试验,西约克郡全部273家基层诊所按初级保健网络集群分层、置换区组随机分组。
  • 干预组接受每两月一次共七次电子加纸质哮喘处方报告,对照组仅接受电子报告。
  • 意向性治疗分析,调整潜在混杂因素及干预前达标情况;因对照组诊所合并,最终分析每组26个集群共270家诊所。

主要发现

  • 主要结局为压力定量吸入装置中预防性吸入剂处方比例,干预组变化-0.15%,对照组-0.19%,风险比1.00(95%CI 0.98至1.03)。
  • 主要结局及所有次要结局均无显著组间差异。
  • 两种干预合并分析显示反馈后存在混合改善的背景趋势。

临床怎么用

  • 本研究未显示纸质反馈附加于电子反馈可改变哮喘处方行为,基层质量改进不宜仅依赖反馈形式升级。

局限性

  • 对照组因诊所合并致最终分析270家而非273家。
  • 原文未报告反馈依从性、污染及长期处方与环保结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background Suboptimal use of preventer inhalers and salbutamol reliever overprescribing are associated with preventable asthma deaths and are a major source of primary care carbon emissions. Audit and feedback produces modest behaviour change by assessing clinical performance and delivering feedback to encourage improvement. Although feedback is increasingly delivered digitally, clinicians may respond more to additional printed feedback reports. We evaluated whether combined digital and paper feedback was more effective than digital-only feedback in promoting safer and greener asthma prescribing at the practice level. Methods In this parallel, cluster randomised controlled trial, all 273 primary care practices in West Yorkshire were assigned within their primary care network clusters by stratified, permuted block randomisation to receive seven bimonthly reports on asthma prescribing either in ‘digital and paper’ (intervention) or ‘digital-only’ (control) formats. The primary outcome was the proportion of preventer inhalers prescribed in pressurised metred-dose devices due to their high carbon footprint. Intervention group allocation was concealed. The intention-to-treat population was analysed and adjusted for both potential confounders and preintervention achievement. Results Final analysis assessed 270 practices in 26 clusters per arm due to practice mergers within the control group. There was no significant difference between the intervention groups based on change in the primary outcome (intervention—0.15%; control—0.19%; risk ratio—1.00; 95% CI 0.98 to 1.03) nor any secondary outcome. Analysis of both interventions combined showed a background trend of mixed improvement following feedback. Conclusions There was no evidence that combined paper and digital feedback was more effective than digital-only feedback, despite the background of mixed improvements following both interventions. Challenges remain to understanding the barriers to influencing the prescribing of preventer inhalers and transitioning inhaler devices towards low-carbon ‘green’ alternatives; however, this study demonstrated the value of an efficient ‘real-world’ trial embedded within an existing quality improvement initiative. Trial registration number NCT05761873 .

来源:BMJ Open Respiratory Research,查看原文。版权归原作者所有。

引用

  1. BMJ Open Respiratory Research:Comparing paper Letters in addition to Emailed Audit and feedback in Refining Asthma treatment to Improve clinical and environmental Results in primary care through a cluster randomised controlled trial: the CLEAR AIR study

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。