逐呼吸睡眠呼吸暂停内分型:区分阻塞性与中枢性睡眠呼吸障碍的自动化方法
本研究利用五种夜间多导睡眠图信号提取九个特征并加权,构建逐呼吸阻塞概率(Pobs),以食管测压测得的上气道阻力为金标准进行验证。在三个数据集共182名受试者、1,962,229次呼吸中,Pobs与上气道阻力在逐呼吸水平和个体水平均显著相关,且夜间变异低。该自动化方法可可靠预测个体阻塞呼吸负荷,辅助判断睡眠呼吸暂停类型。
要点
- Pobs与金标准上气道阻力在逐呼吸水平强相关,测试集1的adj. R²=0.87,测试集2的adj. R²=0.83。
- 个体水平中位Pobs与中位标准化上气道阻力相关,测试集1线性adj. R²=0.59,测试集2为0.45。
- 中位Pobs夜间变异低,组内相关系数ICC(2,1)=0.93。
核心结论
- 逐呼吸阻塞概率Pobs能可靠预测个体整体阻塞呼吸负荷,有助于判断睡眠呼吸暂停类型。
研究设计与样本
- 从五种夜间多导睡眠图信号(气流、胸腹努力、血氧饱和度、鼾声)提取九个特征加权构建Pobs。
- 开发集6人、初始测试集23人(纽约)及第二测试集39人(德国索林根)均行食管测压,用于开发与验证Pobs。
- 另用114名连续两夜多导睡眠图(无食管测压)受试者评估Pobs夜间变异。
主要发现
- 共分析1,962,229次呼吸。
- 逐呼吸水平Pobs与标准化上气道阻力相关:测试集1三次方校正R²=0.87,P<0.001,AUC=0.74;测试集2三次方校正R²=0.83,P<0.001,AUC=0.7。
- 个体水平中位Pobs与中位标准化上气道阻力相关:测试集1线性校正R²=0.59,P<0.001;测试集2线性校正R²=0.45,P<0.001。
- 中位Pobs夜间变异低,ICC(2,1)=0.93。
临床怎么用
- 可利用临床睡眠研究信号自动计算逐呼吸Pobs,辅助区分阻塞性与中枢性睡眠呼吸障碍并指导治疗选择。
- 个体中位Pobs可用于评估整体阻塞呼吸负荷,且夜间稳定性较好。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: Determining whether an individual has obstructive or central sleep apnea is fundamental to selecting the appropriate treatment. Objectives: Here we derive an automated breath-by-breath probability of obstruction, as a surrogate of gold-standard upper airway resistance, using hallmarks of upper airway obstruction visible on clinical sleep studies. Methods: From five nocturnal polysomnography signals (airflow, thoracic and abdominal effort, oxygen saturation, and snore), nine features were extracted and weighted to derive the breath-by-breath probability of obstruction (Pobs). A development and initial test set of 29 subjects (development = 6, test = 23) (New York, NY) and a second test set of 39 subjects (Solingen, Germany), both with esophageal manometry, were used to develop Pobs and validate it against gold-standard upper airway resistance. A separate dataset of 114 subjects with 2 consecutive nocturnal polysomnographies (New York, NY) without esophageal manometry was used to assess the night-to-night variability of Pobs. Measurements and Main Results: A total of 1,962,229 breaths were analyzed. On a breath-by-breath level, Pobs was strongly correlated with normalized upper airway resistance in both test sets (set 1: cubic adjusted [adj.] R2 = 0.87, P < 0.001, area under the receiver operating characteristic curve = 0.74; set 2: cubic adj. R2 = 0.83, P < 0.001, area under the receiver operating characteristic curve = 0.7). On a subject level, median Pobs was associated with the median normalized upper airway resistance (set 1: linear adj. R2 = 0.59, P < 0.001; set 2: linear adj. R2 = 0.45, P < 0.001). Median Pobs exhibited low night-to-night variability [intraclass correlation(2, 1) = 0.93]. Conclusions: Using nearly 2 million breaths from 182 subjects, we show that breath-by-breath probability of obstruction can reliably predict the overall burden of obstructed breaths in individual subjects and can aid in determining the type of sleep apnea.
引用
- Parekh A, Tolbert TM, Mooney AM, et al. Endotyping Sleep Apnea One Breath at a Time: An Automated Approach for Separating Obstructive from Central Sleep-disordered Breathing. Am J Respir Crit Care Med. 2021. PMID: 34449303. doi:10.1164/rccm.202011-4055OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。