剪切波弹性成像:膈肌定性评估的新工具——一项转化研究

Shear Wave Elastography, a New Tool for Diaphragmatic Qualitative Assessment: A Translational Study.
PubMed 文献 · Am J Respir Crit Care Med · 2021-01-01

本研究在102例危重症患者和机械通气仔猪中开展转化研究,采用剪切波弹性成像测量膈肌剪切模量(SM)并同步评估厚度。结果显示,ICU期间膈肌厚度增加与SM下降独立相关(β=-9.34±4.41;P=0.03),仔猪中SM下降伴随肌力丧失、肌纤维萎缩和脂滴积聚,提示厚度增加可能反映肌肉损伤和无力。

要点

  • 剪切波弹性成像可无创测量膈肌剪切模量,反映组织硬度。
  • ICU期间膈肌厚度增加与剪切模量下降独立相关。
  • 仔猪中剪切模量下降伴随肌力丧失和肌纤维萎缩。

核心结论

  • 危重症期间膈肌厚度增加与剪切波弹性成像所示的组织硬度下降相关,符合肌肉损伤和无力的发展。

研究设计与样本

  • 转化研究,纳入102例危重症患者(其中88例接受有创机械通气)及机械通气仔猪。
  • 对患者和仔猪进行系列膈肌超声检查,收集厚度和剪切模量(SM)。
  • 在仔猪中收集跨膈压和膈肌活检。

主要发现

  • 基线时SM为14.3±4.3 kPa,膈肌呼气末厚度为2.0±0.5 mm。
  • 86%的患者厚度较基线变化超过10%,92%的患者SM较基线变化超过10%。
  • 多变量分析显示,ICU期间膈肌厚度增加与SM下降相关(β=-9.34±4.41;P=0.03)。
  • 仔猪机械通气3天期间SM下降与肌力产生丧失、慢肌和快肌纤维萎缩及脂滴积聚增加相关。

临床怎么用

  • 剪切波弹性成像可作为膈肌定性评估的无创工具,辅助识别危重症相关膈肌损伤和无力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Rationale: Prolonged mechanical ventilation is often associated with either a decrease (known atrophy) or an increase (supposed injury) in diaphragmatic thickness. Shear wave elastography is a noninvasive technique that measures shear modulus, a surrogate of tissue stiffness and mechanical properties. Objectives: To describe changes in shear modulus (SM) during the ICU stay and the relationship with alterations in muscle thickness. To perform a comprehensive ultrasound-based characterization of histological and force production changes occurring in the diaphragm. Methods: Translational study using critically ill patients and mechanically ventilated piglets. Serial ultrasound examination of the diaphragm collecting thickness and SM was performed in both patients and piglets. Transdiaphragmatic pressure and diaphragmatic biopsies were collected in piglets. Measurements and Main Results: We enrolled 102 patients, 88 of whom were invasively mechanically ventilated. At baseline, SM was 14.3 ± 4.3 kPa and diaphragm end-expiratory thickness was 2.0 ± 0.5 mm. Decrease or increase by more than 10% from baseline was reported in 86% of the patients for thickness and in 92% of the patients for SM. An increase in diaphragmatic thickness during the stay was associated with a decrease in SM (β = -9.34 ± 4.41; P = 0.03) after multivariable analysis. In the piglet sample, a decrease in SM over 3 days of mechanical ventilation was associated with loss of force production, slow and fast fiber atrophy, and increased lipid droplets accumulation. Conclusions: Increases in diaphragm thickness during critical illness is associated with decreased tissue stiffness as demonstrated by shear wave ultrasound elastography, consistent with the development of muscle injury and weakness. Clinical trial registered with www.clinicaltrials.gov (NCT03550222).

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

引用

  1. Aarab Y, Flatres A, Garnier F, et al. Shear Wave Elastography, a New Tool for Diaphragmatic Qualitative Assessment: A Translational Study. Am J Respir Crit Care Med. 2021. PMID: 34255974. doi:10.1164/rccm.202011-4086OC

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。