文献速递呼吸危重症与机械通气

快速浅呼吸指数预测成功拔管的系统评价与Meta分析

The Usefulness of the Rapid Shallow Breathing Index in Predicting Successful Extubation: A Systematic Review and Meta-analysis.
PubMed 文献 · Chest · 2021-06-26

该系统评价与Meta分析检索6个数据库至2019年9月,纳入48项研究共10,946例患者,评估快速浅呼吸指数(RSBI)预测拔管成功的准确性。RSBI<105预测拔管成功的汇总敏感度为0.83(95%CI 0.78-0.87),特异度较差为0.58(95%CI 0.49-0.66),诊断OR为5.91(95%CI 4.09-8.52)。RSBI<80与80-105阈值结果相似。作为独立试验,RSBI预测拔管成功敏感度中等、特异度差。

要点

  • RSBI<105预测拔管成功敏感度中等(0.83),特异度差(0.58)。
  • RSBI<80与80-105阈值的敏感度、特异度及诊断OR相似。
  • RSBI不宜单独决定拔管,或可作为中概率患者行SBT的允许性标准。

核心结论

  • 作为独立试验,RSBI预测拔管成功的敏感度中等、特异度差。
  • 未来研究应评估RSBI作为允许性标准用于中概率通过SBT患者的作用。

研究设计与样本

  • 系统评价与Meta分析,检索6个数据库从建库至2019年9月。
  • 纳入48项报告RSBI预测拔管成功准确性的研究,共10,946例患者。
  • 研究数据提取与质量评价独立双人完成。

主要发现

  • RSBI<105预测拔管成功的汇总敏感度为0.83(95%CI 0.78-0.87),中等确定性。
  • RSBI<105预测拔管成功的汇总特异度为0.58(95%CI 0.49-0.66),中等确定性。
  • RSBI<105的诊断OR为5.91(95%CI 4.09-8.52)。
  • RSBI<80或80-105阈值的敏感度、特异度及诊断OR相似。
  • 结果在反映不同患者特征和RSBI测量操作差异的多个亚组分析中一致。

关键数值与推荐

  • RSBI<105预测拔管成功:敏感度0.83(95%CI 0.78-0.87),特异度0.58(95%CI 0.49-0.66),诊断OR 5.91(95%CI 4.09-8.52)。
  • RSBI<80与80-105阈值:敏感度、特异度及诊断OR相似。

临床怎么用

  • RSBI不应作为独立试验单独决定拔管。
  • 可考虑将RSBI作为允许性标准,用于中概率通过SBT的患者行SBT。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Clinicians use several measures to ascertain whether individual patients will tolerate liberation from mechanical ventilation, including the rapid shallow breathing index (RSBI). RESEARCH QUESTION: Given varied use of different thresholds, patient populations, and measurement characteristics, how well does RSBI predict successful extubation? STUDY DESIGN AND METHODS: We searched six databases from inception through September 2019 and selected studies reporting the accuracy of RSBI in the prediction of successful extubation. We extracted study data and assessed quality independently and in duplicate. RESULTS: We included 48 studies involving RSBI measurements of 10,946 patients. Pooled sensitivity for RSBI of < 105 in predicting extubation success was moderate (0.83 [95% CI, 0.78-0.87], moderate certainty), whereas specificity was poor (0.58 [95% CI, 0.49-0.66], moderate certainty) with diagnostic ORs (DORs) of 5.91 (95% CI, 4.09-8.52). RSBI thresholds of < 80 or 80 to 105 yielded similar sensitivity, specificity, and DOR. These findings were consistent across multiple subgroup analyses reflecting different patient characteristics and operational differences in RSBI measurement. INTERPRETATION: As a stand-alone test, the RSBI has moderate sensitivity and poor specificity for predicting extubation success. Future research should evaluate its role as a permissive criterion to undergo a spontaneous breathing trial (SBT) for patients who are at intermediate pretest probability of passing an SBT. TRIAL REGISTRY: PROSPERO; No.: CRD42020149196; URL: www.crd.york.ac.uk/prospero/.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Trivedi V, Chaudhuri D, Jinah R, et al. The Usefulness of the Rapid Shallow Breathing Index in Predicting Successful Extubation: A Systematic Review and Meta-analysis. Chest. 2021. PMID: 34181953. doi:10.1016/j.chest.2021.06.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。