文献速递肺结节与肺癌

支气管镜针基共聚焦激光显微内镜(nCLE)用于外周型肺癌实时检测

Bronchoscopic needle-based confocal laser endomicroscopy (nCLE) as a real-time detection tool for peripheral lung cancer.
PubMed 文献 · Thorax · 2021-06-25

本研究评估支气管镜针基共聚焦激光显微内镜(nCLE)对外周型肺癌的可行性与安全性。26例疑似外周型肺癌患者接受rEBUS及透视引导下支气管镜nCLE成像,无不良事件,24例获良好至高质量视频。nCLE在23例肺癌中检出22例,盲法评估者区分肿瘤与气道/肺实质的准确率为95%,观察者间一致性为κ=0.78。

要点

  • nCLE在外周肺病灶活检中可行且安全,26例无不良事件
  • nCLE实时检出23例肺癌中的22例
  • 盲法评估区分恶性肿瘤与气道/肺实质准确率达95%

核心结论

  • 支气管镜nCLE成像对外周肺病灶可行、安全,并能实时检测肺癌。
  • 盲法评估者能准确区分肺癌与气道/肺实质的nCLE视频,显示其作为实时引导工具的潜力。

研究设计与样本

  • 基于(PET-)CT疑似外周型肺癌的患者接受rEBUS和透视引导下柔性支气管镜检查。
  • rEBUS发现病灶后,经透视引导将装载CLE探头的18G针插入选定气道,获取针尖处nCLE视频,随后行抽吸和活检。
  • nCLE视频与相应穿刺的细胞病理及最终诊断比较;5名盲法评估者对肺癌与气道/肺实质的nCLE视频进行两次验证。

主要发现

  • 共26例患者接受nCLE成像,无不良事件发生。
  • 24例(92%)获得良好至高质量视频,最终诊断为肺癌23例、机化性肺炎1例。
  • nCLE在23例肺癌患者中检出22例恶性肿瘤。
  • 盲法评估者区分恶性肿瘤与气道/肺实质的nCLE视频(280次评分)准确率为95%。
  • 观察者间一致性为中等至高度(κ=0.78,95%CI 0.70至0.86),观察者内信度优秀(均值±SD κ=0.81±0.05)。

关键数值与推荐

  • nCLE成像在26例中完成,无不良事件。
  • 24例(92%)获得良好至高质量视频。
  • nCLE检出23例肺癌中的22例。
  • 盲法评估区分恶性肿瘤与气道/肺实质准确率95%(280次评分)。
  • 观察者间一致性κ=0.78(95%CI 0.70至0.86);观察者内信度均值±SD κ=0.81±0.05。

临床怎么用

  • 对于(PET-)CT疑似外周型肺癌患者,可在rEBUS发现病灶后经18G针行nCLE实时成像辅助判断。
  • nCLE视频可用于实时区分恶性肿瘤与气道/肺实质,有望作为实时引导工具。
  • 操作后继续行抽吸和活检以获取病理诊断。

局限性

  • 样本量仅26例,最终诊断肺癌23例、机化性肺炎1例。
  • 研究为可行性评估,未报告随机对照或长期随访数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Diagnosing peripheral lung cancer with the bronchoscope is challenging with near miss of the target lesion as major obstacle. Needle-based confocal laser endomicroscopy (nCLE) enables real-time microscopic tumour visualisation at the needle tip (smart needle). AIM: To investigate feasibility and safety of bronchoscopic nCLE imaging of suspected peripheral lung cancer and to assess whether nCLE imaging allows real-time discrimination between malignancy and airway/lung parenchyma. METHODS: Patients with suspected peripheral lung cancer based on (positron emission tomography-)CT scan underwent radial endobronchial ultrasound (rEBUS) and fluoroscopy-guided flexible bronchoscopy. After rEBUS lesion detection, an 18G needle loaded with the CLE probe was inserted in the selected airway under fluoroscopic guidance. The nCLE videos were obtained at the needle tip, followed by aspirates and biopsies. The nCLE videos were reviewed and compared with the cytopathology of the corresponding puncture and final diagnosis. Five blinded raters validated nCLE videos of lung tumours and airway/lung parenchyma twice. RESULTS: The nCLE imaging was performed in 26 patients. No adverse events occurred. In 24 patients (92%) good to high quality videos were obtained (final diagnosis; lung cancer n=23 and organising pneumonia n=1). The nCLE imaging detected malignancy in 22 out of 23 patients with lung cancer. Blinded raters differentiated nCLE videos of malignancy from airway/lung parenchyma (280 ratings) with a 95% accuracy. The inter-observer agreement was substantial (κ=0.78, 95% CI 0.70 to 0.86) and intra-observer reliability excellent (mean±SD κ=0.81±0.05). CONCLUSION: Bronchoscopic nCLE imaging of peripheral lung lesions is feasible, safe and allows real-time lung cancer detection. Blinded raters accurately distinguished nCLE videos of lung cancer from airway/lung parenchyma, showing the potential of nCLE imaging as real-time guidance tool.

来源:Thorax,查看原文。版权归原作者所有。

引用

  1. Kramer T, Wijmans L, de Bruin M, et al. Bronchoscopic needle-based confocal laser endomicroscopy (nCLE) as a real-time detection tool for peripheral lung cancer. Thorax. 2021. PMID: 34172559. doi:10.1136/thoraxjnl-2021-216885

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。