文献速递哮喘

呼吸振荡法纵向监测哮喘的临床研究

Longitudinal monitoring of asthma in the clinic using respiratory oscillometry.
PubMed 文献 · Respirology · 2021-04-01

本研究在3年内对186名成人哮喘患者进行855次访视,评估呼吸振荡法(FOT)与肺功能及症状控制的纵向一致性。结果显示FOT与FEV1变化中度一致,但两者与ACT变化相关性弱,提示哮喘需多模式评估。

要点

  • FOT与FEV1纵向变化中度一致(κ=0.34),但与症状控制相关性弱。
  • FeNO变化与肺功能或ACT变化无相关性。
  • 稳定期哮喘FOT的重复性界限较健康人至少宽两倍。

核心结论

  • 成人哮喘中FOT与肺功能纵向变化中度一致,但两者与哮喘控制变化相关性差,强调多模式评估而非仅凭症状。

研究设计与样本

  • 为期3年的纵向观察研究,纳入成人哮喘患者186例,共855次访视,平均访视间隔114±95天。

主要发现

  • X5与FEV1访视间变化一致性为中度(κ=0.34,p=0.001),ACT与FEV1一致性弱(κ=0.18,p=0.001)。
  • FeNO变化与肺功能或ACT变化无相关性(κ<0.05,p>0.1)。
  • 稳定期哮喘(75例,132次访视)FEV1的重复性界限为0.42 L,R5为2.06 cm H2O s L-1,X5为2.75 cm H2O s L-1,至少为健康人已发表值的两倍。

临床怎么用

  • 临床中可结合FOT与肺功能纵向监测哮喘,但需注意二者与症状控制变化不一致,应综合评估。
  • FOT纵向重复性界限有助于解读个体患者的变化。

局限性

  • 研究为单中心三级门诊成人哮喘患者,结果可能不适用于其他人群。
  • 稳定期哮喘亚组样本量较小(75例),重复性界限需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVE: Asthma guidelines emphasize the importance of assessing lung function and symptoms. The forced oscillation technique (FOT) and its longitudinal relationship with spirometry and symptoms are unresolved. We examined concordance between longitudinal spirometry, FOT and symptom control, and determined FOT limits of agreement in stable asthma. METHODS: Over a 3-year period, adults with asthma attending a tertiary clinic completed the asthma control test (ACT), fraction of exhaled nitric oxide (FeNO), FOT and spirometry. Analysis included between-visit concordance for significant change using Cohen's kappa (κ) and stable asthma FOT limits of agreement. RESULTS: Data (n = 186) from 855 visits (mean ± SD 4.6 ± 3.0 visits), 114 ± 95 days apart, were analysed. Between-visit concordance was moderate between reactance at 5 Hz (X5) and forced expiratory volume in 1 s (FEV1 ) (κ = 0.34, p = 0.001), and weak between ACT and FEV1 (κ = 0.18, p = 0.001). Change in FeNO did not correlate with lung function or ACT (κ < 0.05, p > 0.1). Stable asthma between visits (n = 75; 132 visits) had reduced lung function variability, but comparable concordance to the entire cohort. Limits of agreement for FEV1 (0.42 L), resistance at 5 Hz (2.06 cm H2 O s L-1 ) and X5 (2.75 cm H2 O s L-1 ) in stable asthma were at least twofold greater than published values in health. CONCLUSION: In adults with asthma, there is moderate concordance between longitudinal change in FOT and spirometry. Both tests relate poorly to changes in asthma control, highlighting the need for multi-modal assessment in asthma rather than symptoms alone. The derivation of longitudinal FOT limits of agreement will assist in its clinical interpretation.

来源:Respirology,查看原文。版权归原作者所有。

引用

  1. Cottee AM, Seccombe LM, Thamrin C, et al. Longitudinal monitoring of asthma in the clinic using respiratory oscillometry. Respirology. 2021. PMID: 33797141. doi:10.1111/resp.14053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。