文献速递呼吸危重症与机械通气呼吸道感染

持续气动调节气管导管套囊压力预防严重创伤机械通气患者呼吸机相关性肺炎:AGATE多中心随机对照研究

Continuous Pneumatic Regulation of Tracheal Cuff Pressure to Decrease Ventilator-associated Pneumonia in Trauma Patients Who Were Mechanically Ventilated: The AGATE Multicenter Randomized Controlled Study.
PubMed 文献 · Chest · 2021-03-13

在13个法国ICU开展开放标签随机对照优势试验,纳入434例严重创伤需有创机械通气≥48小时的成人患者,比较气动装置持续调节套囊压力与每日三次便携式测压计手动评估对28天内呼吸机相关性肺炎(VAP)发生率的影响。结果显示两组VAP发生率分别为33.8%与29.4%,调整后亚分布风险比0.96(95%CI 0.76-1.20;

要点

  • 严重创伤机械通气患者中,气动装置持续调节套囊压力未降低28天内VAP发生率。
  • 干预组与对照组VAP发生率分别为33.8%和29.4%,差异无统计学意义。
  • 未观察到与气动装置使用相关的严重不良事件。

核心结论

  • 在严重创伤机械通气患者中,使用气动装置持续调节气管导管套囊压力在预防VAP方面不优于每日三次手动测压的常规护理。

研究设计与样本

  • 开放标签、随机对照优势试验,在13个法国ICU开展,纳入年龄≥18岁、损伤严重度评分>15且需要有创机械通气≥48小时的严重创伤成人患者。
  • 共招募434例患者,按1:1随机分为干预组216例和对照组218例,主要结局为气管插管后28天内发生VAP的比例,由两名对分组设盲的评估者在改良意向治疗人群中判定。

主要发现

  • 未发现与气动装置使用相关的严重不良事件。

临床怎么用

  • 对于严重创伤机械通气患者,持续气动调节套囊压力不应被视为优于常规手动测压的VAP预防策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ventilator-associated pneumonia (VAP) is the most frequent health care-associated infection in severely ill patients, and aspiration of contaminated oropharyngeal content around the cuff of the tracheal tube is the main route of contamination. RESEARCH QUESTION: Is continuous regulation of tracheal cuff pressure using a pneumatic device superior to manual assessment three times daily using a portable manometer (routine care) in preventing VAP in patients with severe trauma? STUDY DESIGN AND METHODS: In this open-label, randomized controlled superiority trial conducted in 13 French ICUs, adults (age ≥ 18 years) with severe trauma (Injury Severity Score > 15) and requiring invasive mechanical ventilation for ≥ 48 h were enrolled. Patients were randomly assigned (1:1) via a secure Web-based random number generator in permuted blocks of variable sizes to one of two groups according to the method of tracheal cuff pressure control. The primary outcome was the proportion of patients developing VAP within 28 days following the tracheal intubation, as determined by two assessors masked to group assignment, in the modified intention-to-treat population. This study is closed to new participants. RESULTS: A total of 434 patients were recruited between July 31, 2015, and February 15, 2018, of whom 216 were assigned to the intervention group and 218 to the control group. Seventy-three patients (33.8%) developed at least one episode of VAP within 28 days following the tracheal intubation in the intervention group compared with 64 patients (29.4%) in the control group (adjusted subdistribution hazard ratio, 0.96; 95% CI, 0.76-1.20; P = .71). No serious adverse events related to the use of the pneumatic device were noted. INTERPRETATION: Continuous regulation of cuff pressure of the tracheal tube using a pneumatic device was not superior to routine care in preventing VAP in patients with severe trauma. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT02534974; URL: www.clinicaltrials.gov.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Marjanovic N, Boisson M, Asehnoune K, et al. Continuous Pneumatic Regulation of Tracheal Cuff Pressure to Decrease Ventilator-associated Pneumonia in Trauma Patients Who Were Mechanically Ventilated: The AGATE Multicenter Randomized Controlled Study. Chest. 2021. PMID: 33727034. doi:10.1016/j.chest.2021.03.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。