机械通气危重患者不同氧合目标的分类与效果:随机对照试验的网络荟萃分析
该系统评价纳入8项RCT共2532例机械通气危重成人患者,将氧合目标分为保守(PaO2 55-90 mmHg)、中等(PaO2 90-150 mmHg)和宽松(PaO2 >150 mmHg)三类,进一步四分法将保守分为远保守(55-70 mmHg)和保守(70-90 mmHg)。网络荟萃分析显示不同氧合目标30天死亡率无差异,但SUCRA和生存曲线提示中等目标及四分法保守目标可能优于宽松和远保守目标,维持PaO2 70-150 mmHg的潜在优势尚待验证。
要点
- 不同氧合目标(保守、中等、宽松)的30天死亡率无显著差异。
- 四分法远保守与保守目标间结果与三分法一致,无死亡率差异。
- SUCRA提示中等目标(PaO2 90-150 mmHg)和四分法保守目标(70-90 mmHg)可能较优。
核心结论
- 不同氧合目标不导致机械通气危重患者死亡率差异。
- 维持PaO2在70-150 mmHg的潜在优势尚待验证。
研究设计与样本
- 系统评价与网络荟萃分析,纳入8项RCT共2532例机械通气危重成人患者。
- 氧合目标按三分法分为保守(PaO2 55-90 mmHg)、中等(90-150 mmHg)和宽松(>150 mmHg)。
- 四分法进一步将保守分为远保守(55-70 mmHg)和保守(70-90 mmHg)。
- 主要结局为30天死亡率,次要结局包括ICU、住院和90天死亡率。
主要发现
- 保守 vs 中等目标:RR 1.08,95% CrI 0.85-1.36,中等质量证据。
- 中等 vs 宽松目标:RR 0.83,95% CrI 0.61-1.10,低质量证据。
- 保守 vs 宽松目标:RR 0.89,95% CrI 0.61-1.30,低质量证据。
- 次要结局在不同目标间无差异,三分法与四分法结果一致。
- SUCRA和生存曲线提示三分法中等目标及四分法保守目标可能优于宽松和远保守目标。
关键数值与推荐
- 三分法:保守PaO2 55-90 mmHg,中等PaO2 90-150 mmHg,宽松PaO2 >150 mmHg。
- 四分法:远保守PaO2 55-70 mmHg,保守PaO2 70-90 mmHg。
- 主要结局30天死亡率,效应量用RR和95% CrI表示。
临床怎么用
- 机械通气危重患者氧合目标选择需个体化,避免远保守或过于宽松。
- 可考虑将PaO2维持在70-150 mmHg范围内,但需进一步验证。
局限性
- 纳入研究数量较少(8项),样本量有限(2532例)。
- 部分比较证据质量低,结论需谨慎解读。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal oxygenation in mechanically ventilated critically ill patients remains unclear. METHODS: We performed a systematic review of randomised controlled trials (RCTs) with the aim to classify oxygenation goals and investigate their relative effectiveness. RCTs investigating different oxygenation goal-directed mechanical ventilation in critically ill adult patients were eligible for the analysis. The trinary classification classified oxygenation goals into conservative (partial pressure of arterial oxygen (P aO2 ) 55-90 mmHg), moderate (P aO2 90-150 mmHg) and liberal (P aO2 >150 mmHg). The quadruple classification further divided the conservative goal from the trinary classification into far-conservative (P aO2 55-70 mmHg) and conservative (P aO2 70-90 mmHg) goals. The primary outcome was 30-day mortality. The secondary outcomes included intensive care unit, hospital and 90-day mortalities. The effectiveness was estimated by the relative risk and 95% credible interval (CrI) using network meta-analysis and visualised using surface under the cumulative ranking curve (SUCRA) scores and survival curves. RESULTS: We identified eight eligible studies involving 2532 patients. There were no differences between conservative and moderate goals (relative risk 1.08, 95% CrI 0.85-1.36; moderate quality), between moderate and liberal goals (relative risk 0.83, 95% CrI 0.61-1.10; low quality) or between conservative and liberal goals (relative risk 0.89, 95% CrI 0.61-1.30; low quality) based on the trinary classification. There were no differences in secondary outcomes among the different goals. The results were consistent between the trinary and quadruple classifications. The SUCRA scores and survival curves suggested that the moderate goal in the trinary and quadruple classifications and the conservative goal in the quadruple classification may be superior to the liberal and far-conservative goals. CONCLUSIONS: Different oxygenation goals do not lead to different mortalities in mechanically ventilated critically ill patients. The potential superiority of maintaining P aO2 in the range 70-150 mmHg remains to be validated.
引用
- Zhao X, Xiao H, Dai F, et al. Classification and effectiveness of different oxygenation goals in mechanically ventilated critically ill patients: network meta-analysis of randomised controlled trials. Eur Respir J. 2021. PMID: 33632796. doi:10.1183/13993003.02928-2020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。