文献速递呼吸危重症与机械通气

保护性通气策略对中重度ARDS疗效比较:网络荟萃分析

Comparative Effectiveness of Protective Ventilation Strategies for Moderate and Severe Acute Respiratory Distress Syndrome. A Network Meta-Analysis.
PubMed 文献 · Am J Respir Crit Care Med · 2021-01-01

该网络荟萃分析纳入34项随机试验、9085例以中重度为主的ARDS成人患者,比较低潮气量、高潮气量、高PEEP、俯卧位通气、高频振荡及VV-ECMO对死亡率的影响。结果显示低潮气量联合俯卧位通气降低死亡率效果最佳,高潮气量最差,高频振荡及高潮气量联合俯卧位无支持证据。

要点

  • 低潮气量联合俯卧位通气为降低中重度ARDS死亡率的最佳策略。
  • 高潮气量通气与死亡率增加相关,应避免使用。
  • 高频振荡及高潮气量联合俯卧位通气缺乏支持证据。

核心结论

  • 低潮气量联合俯卧位通气与中重度ARDS危重成人死亡率最大幅度降低相关。

研究设计与样本

  • 网络荟萃分析纳入34项随机试验,共9085例以中重度为主的ARDS成人患者。
  • 基线PaO2/FiO2中位数118(四分位距110-143),采用GRADE方法评估证据确定性。

主要发现

  • 俯卧位通气联合低潮气量对比低潮气量,RR 0.74(95%CI 0.60-0.92),高确定性。
  • VV-ECMO对比低潮气量RR 0.78(95%CI 0.58-1.05),对比高潮气量RR 0.66(95%CI 0.49-0.88),确定性较低。
  • 高PEEP联合低潮气量对比低潮气量RR 0.91(95%CI 0.81-1.03),低确定性;对比高潮气量RR 0.77(95%CI 0.65-0.91),中等确定性。
  • 高潮气量对比低潮气量RR 1.19(95%CI 1.02-1.37),中等确定性。
  • 高频振荡或高潮气量联合俯卧位通气未获支持。

关键数值与推荐

  • 俯卧位通气联合低潮气量:RR 0.74(95%CI 0.60-0.92),高确定性。
  • VV-ECMO对比高潮气量:RR 0.66(95%CI 0.49-0.88),确定性较低。
  • 高潮气量对比低潮气量:RR 1.19(95%CI 1.02-1.37),中等确定性。

临床怎么用

  • 对中重度ARDS成人患者,优先采用低潮气量联合俯卧位通气。
  • 避免使用高潮气量通气策略。
  • VV-ECMO可考虑用于极重度ARDS(基线PaO2/FiO2<75),但证据确定性较低。

局限性

  • VV-ECMO仅限用于极重度ARDS(平均基线PaO2/FiO2<75),证据确定性较低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Rationale: Choosing the best ventilation strategy for acute respiratory distress syndrome (ARDS) is complex, yet it is highly relevant to clinicians during a respiratory pandemic. Objectives: To compare the effects of low Vt, high Vt, high positive end-expiratory pressure (PEEP), prone ventilation, high-frequency oscillation, and venovenous extracorporeal membrane oxygenation (VV ECMO) on mortality in ARDS. Methods: We performed a network meta-analysis of randomized trials. We applied the Grading of Recommendations Assessment, Development and Evaluation methodology to discern the relative effect of interventions on mortality. Measurements and Main Results: We analyzed 34 trials including 9,085 adults with primarily moderate-to-severe ARDS (median baseline PaO2/FiO2, 118; interquartile range, 110-143). Prone positioning combined with low Vt was the best strategy (risk ratio [RR], 0.74 [95% confidence interval (CI), 0.60-0.92] vs. low Vt; high certainty). VV ECMO was also rated among the best (RR, 0.78 [95% CI, 0.58-1.05] vs. low Vt; RR, 0.66; [95% CI, 0.49-0.88] vs. high Vt) but was rated with lower certainty because VV ECMO was restricted to very severe ARDS (mean baseline PaO2/FiO2<75). High PEEP combined with low Vt was rated intermediately (RR, 0.91 [95% CI, 0.81-1.03] vs. low Vt; low certainty; RR, 0.77 [95% CI, 0.65-0.91] vs. high Vt; moderate certainty). High Vt was rated worst (RR, 1.19 [95% CI, 1.02-1.37] vs. low Vt; moderate certainty), and we found no support for high-frequency oscillation or high Vt with prone ventilation. Conclusions: These findings suggest that combining low Vt with prone ventilation is associated with the greatest reduction in mortality for critically ill adults with moderate-to-severe ARDS.

来源:Am J Respir Crit Care Med,查看原文。版权归原作者所有。

引用

  1. Sud S, Friedrich JO, Adhikari NKJ, et al. Comparative Effectiveness of Protective Ventilation Strategies for Moderate and Severe Acute Respiratory Distress Syndrome. A Network Meta-Analysis. Am J Respir Crit Care Med. 2021. PMID: 33406009. doi:10.1164/rccm.202008-3039OC

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。